A new disposable amperometric NADH sensor based on screen-printed electrode modified with reduced graphene oxide/polyneutral red/gold nanoparticle

被引:10
作者
Kamac, Melike Bilgi [1 ]
Onat, Eda Kiymaz [1 ]
Yilmaz, Merve [1 ]
机构
[1] Cankiri Karatekin Univ, Dept Chem, Fac Sci, Cankiri, Turkey
关键词
NADH sensor; polyneutralred; reduced graphene oxide; screen-printed electrode; human serum; ELECTROCATALYTIC OXIDATION; CARBON ELECTRODE; CONDUCTING POLYMER; POLY(NEUTRAL RED); ELECTROCHEMICAL DETERMINATION; BIOSENSOR APPLICATION; OXIDE; NANOCOMPOSITES; PLATFORM;
D O I
10.1080/03067319.2019.1703965
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new amperometric NADH sensor was developed based on screen-printed electrode (SPCE) modified with reduced graphene oxide (RGO), polyneutral red (PNR) and gold nanoparticles (AuNP). Electrochemical behaviour of NADH on SPCE/RGO/PNR/AuNP was investigated. The prepared sensor showed a high electrocatalytic effect on the oxidation of NADH. The sensor response for NADH was investigated as a function of pH and working potential. Optimum values of these parameters in the NADH determination were found as 7.0 for pH and +0.15 V for working potential. Sensitivity, linear range, limit of detection and limit of quantification of the sensor were found to be 8.72 mu AmM-1, 5 to 3170 mu M, 0.384 mu M and 1.18 mu M, respectively. The relative standard deviation (RSD) was calculated to be 1.93% (for n = 10). The operational stability studies have shown that the initial amperometric response of sensor to NADH decreased by 56.15% at the 60th day. Storage life studies have shown that the sensitivity of the biosensor decreased by 48.72% at the end of 12 weeks. The developed sensor has been tested for NADH determination in the human serum sample. The developed NADH sensor is promising to be used for NADH analysis in human serum samples as simple, practical and disposable device without requiring laborious sample pre-treatment producers.
引用
收藏
页码:419 / 431
页数:13
相关论文
共 50 条
  • [11] Electrochemically Reduced Graphene Oxide as Screen-printed Electrode Modifier for Fenamiphos Determination
    Gevaerd, A.
    Watanabe, E. Y.
    Fernandes, K.
    Papi, M. A. P.
    Banks, C. E.
    Bergamini, M. F.
    Marcolino-Junior, L. H.
    [J]. ELECTROANALYSIS, 2020, 32 (08) : 1689 - 1695
  • [12] Paper-based amperometric sensor for determination of acetylcholinesterase using screen-printed graphene electrode
    Panraksa, Yosita
    Siangproh, Weena
    Khampieng, Thitikan
    Chailapakul, Orawon
    Apilux, Amara
    [J]. TALANTA, 2018, 178 : 1017 - 1023
  • [13] A novel and Disposable Amperometric Hydrazine Sensor based on Polydimethyldiallylamine Stabilized Copper(II)hexacyanoferrate Nanocubes modified Screen-printed Carbon Electrode
    Ramaraj, Sukanya
    Sakthivel, Rajalakshmi
    Chen, Shen-Ming
    Palanisamy, Selvakumar
    Velusamy, Vijayalakshmi
    Chen, Tse-Wei
    Ramaraj, Sayee Kannan
    Pandian, Kannaiyan
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (06): : 5567 - 5580
  • [14] An Electrochemical Sensor Based on Gold-Nanocluster-Modified Graphene Screen-Printed Electrodes for the Detection of β-Lactoglobulin in Milk
    Hong, Jingyi
    Wang, Yuxian
    Zhu, Liying
    Jiang, Ling
    [J]. SENSORS, 2020, 20 (14) : 1 - 12
  • [15] Amperometric immunoassay for the detection of Salmonella pullorum using a screen - printed carbon electrode modified with gold nanoparticle-coated reduced graphene oxide and immunomagnetic beads
    Fei, Jianfeng
    Dou, Wenchao
    Zhao, Guangying
    [J]. MICROCHIMICA ACTA, 2016, 183 (02) : 757 - 764
  • [16] Disposable Electrochemical Sensor for Food Colorants Detection by Reduced Graphene Oxide and Methionine Film Modified Screen Printed Carbon Electrode
    Akkapinyo, Chutimon
    Subannajui, Kittitat
    Poo-arporn, Yingyot
    Poo-arporn, Rungtiva P.
    [J]. MOLECULES, 2021, 26 (08):
  • [17] Gold nanoparticles modified ceria nanoparticles for the oxidation of hydrazine with disposable screen-printed electrode
    Sun, Haiyi
    Zhao, Shugao
    Qu, Fengli
    [J]. MEASUREMENT, 2012, 45 (05) : 1111 - 1113
  • [18] Electrochemically Reduced Graphene Oxide Modified Screen-Printed Electrodes for Sensitive Determination of Acetylsalicylic Acid
    Zhao, Chunzhi
    Ling, Jihong
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (11): : 10177 - 10186
  • [19] NADH oxidation on screen-printed electrode modified with a new phenothiazine diazonium salt
    Doumeche, Bastien
    Blum, Loic J.
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (10) : 1398 - 1402
  • [20] Electrochemical Sensor for Determination of Paracetamol Based on Reduced Graphene Oxide/Polypyrrole Nanotubes Nanocomposite Modified Screen Printed Electrode in Pharmaceutical Samples
    Jahani, Peyman Mohammadzadeh
    Zaimbashi, Reza
    Tajik, Somayeh
    Beitollahi, Hadi
    [J]. CHEMICAL METHODOLOGIES, 2025, 9 (04): : 251 - 267