Real-time continuous measurement of intraoperative trace exhaled propofol by planar differential mobility spectrometry

被引:0
|
作者
Li, Yang [1 ]
Jiang, Dandan [1 ]
Zhao, Kun [1 ]
Li, Enyou [2 ]
Liu, Yiping [2 ]
Chen, Chuang [1 ]
Wang, Weiguo [1 ]
Li, Haiyang [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, CAS Key Lab Separat Sci Analyt Chem, Dalian 116023, Liaoning, Peoples R China
[2] Harbin Med Univ, Dept Anesthesiol, Affiliated Hosp 1, Harbin 150001, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
ION MOBILITY; ONLINE MEASUREMENT; HUMAN BREATH; FIELD; SEPARATION; GAS; IDENTIFICATION; PLASMA;
D O I
10.1039/d1ay00179e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to study anesthetic pharmacokinetics and adequately adjust the anaesthesia depth of patients, real-time measurement of the intraoperative exhaled propofol concentration is of significant importance for anaesthetists. Although a series of analytical techniques and methods have been developed for the detection of exhaled propofol, differential mobility spectrometry (DMS) with the advantages of a much smaller instrument, faster response time and cheaper cost shows great potential for the point of care in the operating room. In this paper, a planar DMS was constructed for real-time continuous measurement of trace propofol in exhaled air. The effects of DMS parameters, such as the radio frequency voltage, the drift gas flow rate and the sampling flow rate of exhaled air on the propofol measurement under high humidity conditions were carefully investigated and discussed. Under the optimum experimental conditions, the limit of detection (LOD) for propofol was achieved in ppbv with a linear range of 0.5 to 25 ppbv, both of which meet clinical requirements. Finally, the planar DMS was performed on a patient undergoing thyroidectomy surgery to real-time monitor the intraoperative exhaled propofol, which demonstrated the capability of DMS for sensitive and breath-by-breath continuous measurement of intraoperative trace exhaled propofol.
引用
收藏
页码:2624 / 2630
页数:7
相关论文
共 18 条
  • [1] Trap-and-release membrane inlet ion mobility spectrometry for on-line measurement of trace propofol in exhaled air
    Zhou, Qinghua
    Li, Enyou
    Wang, Xin
    Gong, Yulei
    Hua, Lei
    Wang, Weiguo
    Qu, Tuanshuai
    Li, Jinghua
    Liu, Yiping
    Wang, Changsong
    Li, Haiyang
    ANALYTICAL METHODS, 2014, 6 (03) : 698 - 703
  • [2] Breath-by-breath measurement of intraoperative propofol by unidirectional anisole-assisted photoionization ion mobility spectrometry via real-time correction of humidity
    Jiang, Dandan
    Chen, Chuang
    Wang, Weimin
    Wang, Weiguo
    Li, Mei
    Wang, Xin
    Liu, Yiping
    Li, Enyou
    Li, Haiyang
    ANALYTICA CHIMICA ACTA, 2021, 1150
  • [3] Online Monitoring of Intraoperative Exhaled Propofol by Acetone-Assisted Negative Photoionization Ion Mobility Spectrometry Coupled with Time-Resolved Purge Introduction
    Jiang, Dandan
    Li, Enyou
    Zhou, Qinghua
    Wang, Xin
    Li, Hanwei
    Ju, Bangyu
    Guo, Lei
    Liu, Desheng
    Li, Haiyang
    ANALYTICAL CHEMISTRY, 2018, 90 (08) : 5280 - 5289
  • [4] Possible strategy to use differential mobility spectrometry in real time applications
    Anttalainen, Osmo
    Puton, Jaroslaw
    Kontunen, Anton
    Karjalainen, Markus
    Kumpulainen, Pekka
    Oksala, Niku
    Safaei, Zahra
    Roinel, Antti
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2020, 23 (01) : 1 - 8
  • [5] Direct mass spectrometry analysis of exhaled human breath in real-time
    Zhang, Xiaoping
    Frankevich, Vladimir
    Ding, Jianhua
    Ma, Yuanyuan
    Chingin, Konstantin
    Chen, Huanwen
    MASS SPECTROMETRY REVIEWS, 2025, 44 (01) : 43 - 61
  • [6] Differential mobility spectrometry/mass spectrometry: The design of a new mass spectrometer for real-time chemical analysis in the field
    Manard, Manuel J.
    Trainham, Rusty
    Weeks, Stephan
    Coy, Stephen L.
    Krylov, Evgeny V.
    Nazarov, Erkinjon G.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 295 (03) : 138 - 144
  • [7] Gas chromatograph-surface acoustic wave for quick real-time assessment of blood/exhaled gas ratio of propofol in humans
    Chen, X.
    Zhang, X. L.
    Liu, L.
    Chen, Y.
    Piao, M. Y.
    Zhang, F. J.
    Wu, W. D.
    Zhong, Y. B.
    Sun, K.
    Zou, Y. C.
    Zhang, X.
    Wang, D.
    Wang, P.
    Yan, M.
    BRITISH JOURNAL OF ANAESTHESIA, 2014, 113 (05) : 807 - 814
  • [8] Real-time measurement of fibers using an HY-differential mobility analyzer with an optical particle counter (KOFAM)
    Choi, Sungwon
    Jang, Kwangmyung
    Park, Kyunghoon
    Kim, Hyunwook
    PLOS ONE, 2017, 12 (08):
  • [9] Development and validation of a novel UV-TOF MS method for real-time exhaled propofol analysis in Beagles
    Chang, Pan
    Li, Xiaoxiao
    Liu, Xing
    Kang, Yi
    Gong, Deying
    Li, Wenwen
    Zhao, Zhongjun
    Zhu, Tao
    Liu, Jin
    Zhang, Wen-sheng
    ANALYTICAL METHODS, 2025, 17 (11) : 2467 - 2476
  • [10] WMS based dual-range real-time trace sensor for ethane detection in exhaled breath
    Li, Guolin
    Wu, Yunhui
    Zhang, Zecheng
    Zhang, Xuena
    Ma, Kun
    Jiao, Yue
    Li, Jiarui
    Liu, Yajing
    Song, Yimeng
    Zhao, Hao
    Zhai, Shenqiang
    Li, Qiang
    OPTICS AND LASERS IN ENGINEERING, 2022, 159