Intracardiac Flow at 4D CT: Comparison with 4D Flow MRI

被引:37
作者
Lantz, Jonas [1 ,2 ]
Gupta, Vikas [1 ,2 ]
Henriksson, Lilian [2 ,3 ]
Karlsson, Matts [2 ,4 ]
Persson, Anders [2 ,3 ]
Carlhall, Carl-Johan [2 ,5 ]
Ebbers, Tino [1 ,2 ]
机构
[1] Linkoping Univ, Div Cardiovasc Med, Dept Med & Hlth Sci, SE-58183 Linkoping, Sweden
[2] Linkoping Univ, Ctr Med Image Sci & Visualizat CMIV, SE-58183 Linkoping, Sweden
[3] Linkoping Univ, Div Radiol, Dept Med & Hlth Sci, SE-58183 Linkoping, Sweden
[4] Linkoping Univ, Div Appl Thermodynam & Fluid Mech, Dept Management & Engn, SE-58183 Linkoping, Sweden
[5] Linkoping Univ, Dept Clin Physiol, Dept Med & Hlth Sci, SE-58183 Linkoping, Sweden
关键词
VENTRICULAR KINETIC-ENERGY; BLOOD-FLOW; DIAGNOSTIC PERFORMANCE; COMPUTED-TOMOGRAPHY; HEMODYNAMICS; RESERVE; HEART; QUANTIFICATION; ANGIOGRAPHY; DYNAMICS;
D O I
10.1148/radiol.2018173017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate four-dimensional (4D) flow CT for the assessment of intracardiac blood flow patterns as compared with 4D flow MRI. Materials and Methods: This prospective study acquired coronary CT angiography and 4D flow MRI data between February and December 2016 in a cohort of 12 participants (age range, 36-74 years; mean age, 57 years; seven men [age range, 36-74 years; mean age, 57 years] and five women [age range, 52-73 years; mean age, 64 years]). Flow simulations based solely on CT-derived cardiac anatomy were assessed together with 4D flow MRI measurements. Flow patterns, flow rates, stroke volume, kinetic energy, and flow components were quantified for both techniques and were compared by using linear regression. Results: Cardiac flow patterns obtained by using 4D flow CT were qualitatively similar to 4D flow MRI measurements, as graded by three independent observers. The Cohen k score was used to assess intraobserver variability (0.83, 0.79, and 0.70) and a paired Wilcoxon rank-sum test showed no significant change (P>.05) between gradings. Peak flow rate and stroke volumes between 4D flow MRI measurements and 4D flow CT measurements had high correlation (r = 0.98 and r = 0.81, respectively; P<.05 for both). Integrated kinetic energy quantified at peak systole correlated well (r = 0.95, P<.05), while kinetic energy levels at early and late filling showed no correlation. Flow component analysis showed high correlation for the direct and residual components, respectively (r = 0.93, P<.05 and r = 0.87, P<.05), while the retained and delayed components showed no correlation. Conclusion: Four-dimensional flow CT produced qualitatively and quantitatively similar intracardiac blood flow patterns compared with the current reference standard, four-dimensional flow MRI. (c) RSNA, 2018
引用
收藏
页码:51 / 58
页数:8
相关论文
共 24 条
  • [11] Left ventricular fluid kinetic energy time curves in heart failure from cardiovascular magnetic resonance 4D flow data
    Kanski, Mikael
    Arvidsson, Per M.
    Toger, Johannes
    Borgquist, Rasmus
    Heiberg, Einar
    Carlsson, Marcus
    Arheden, Hakan
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [12] elastix: A Toolbox for Intensity-Based Medical Image Registration
    Klein, Stefan
    Staring, Marius
    Murphy, Keelin
    Viergever, Max A.
    Pluim, Josien P. W.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) : 196 - 205
  • [13] Patient-Specific Simulation of Cardiac Blood Flow From High-Resolution Computed Tomography
    Lantz, Jonas
    Henriksson, Lilian
    Persson, Anders
    Karlsson, Matts
    Ebbers, Tino
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (12):
  • [14] CT Angiography (CTA) and Diagnostic Performance of Noninvasive Fractional Flow Reserve: Results From the Determination of Fractional Flow Reserve by Anatomic CTA (DeFACTO) Study
    Leipsic, Jonathon
    Yang, Tae-Hyun
    Thompson, Angus
    Koo, Bo-Kwon
    Mancini, G. B. John
    Taylor, Carolyn
    Budoff, Matthew J.
    Park, Hyung-Bok
    Berman, Daniel S.
    Min, James K.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (05) : 989 - 994
  • [15] Patient-specific modelling of whole heart anatomy, dynamics and haemodynamics from four-dimensional cardiac CT images
    Mihalef, Viorel
    Ionasec, Razvan Ioan
    Sharma, Puneet
    Georgescu, Bogdan
    Voigt, Ingmar
    Suehling, Michael
    Comaniciu, Dorin
    [J]. INTERFACE FOCUS, 2011, 1 (03) : 286 - 296
  • [16] Computational modeling of cardiac hemodynamics: Current status and future outlook
    Mittal, Rajat
    Seo, Jung Hee
    Vedula, Vijay
    Choi, Young J.
    Liu, Hang
    Huang, H. Howie
    Jain, Saurabh
    Younes, Laurent
    Abraham, Theodore
    George, Richard T.
    [J]. JOURNAL OF COMPUTATIONAL PHYSICS, 2016, 305 : 1065 - 1082
  • [17] Diagnostic Performance of Noninvasive Fractional Flow Reserve Derived From Coronary Computed Tomography Angiography in Suspected Coronary Artery Disease The NXT Trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps)
    Norgaard, Bjarne L.
    Leipsic, Jonathon
    Gaur, Sara
    Seneviratne, Sujith
    Ko, Brian S.
    Ito, Hiroshi
    Jensen, Jesper M.
    Mauri, Laura
    De Bruyne, Bernard
    Bezerra, Hiram
    Osawa, Kazuhiro
    Marwan, Mohamed
    Naber, Christoph
    Erglis, Andrejs
    Park, Seung-Jung
    Christiansen, Evald H.
    Kaltoft, Anne
    Lassen, Jens F.
    Botker, Hans Erik
    Achenbach, Stephan
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : 1145 - 1155
  • [18] Multiplanar Visualization of Blood Flow Using Echocardiographic Particle Imaging Velocimetry
    Sengupta, Partho P.
    Pedrizetti, Gianni
    Narula, Jagat
    [J]. JACC-CARDIOVASCULAR IMAGING, 2012, 5 (05) : 566 - 569
  • [19] Decreased Diastolic Ventricular Kinetic Energy in Young Patients with Fontan Circulation Demonstrated by Four-Dimensional Cardiac Magnetic Resonance Imaging
    Sjoberg, Pia
    Heiberg, Einar
    Wingren, Par
    Johansson, Jens Ramgren
    Malm, Torsten
    Arheden, Hakan
    Liuba, Petru
    Carlsson, Marcus
    [J]. PEDIATRIC CARDIOLOGY, 2017, 38 (04) : 669 - 680
  • [20] Test-retest variability of left ventricular 4D flow cardiovascular magnetic resonance measurements in healthy subjects
    Stoll, Victoria M.
    Loudon, Margaret
    Eriksson, Jonatan
    Bissell, Malenka M.
    Dyverfeldt, Petter
    Ebbers, Tino
    Myerson, Saul G.
    Neubauer, Stefan
    Carlhall, Carl-Johan
    Hess, Aaron T.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20