Programmable flow-based dynamic sorptive microextraction exploiting an octadecyl chemically modified rotating disk extraction system for the determination of acidic drugs in urine

被引:33
作者
Manzo, Valentina [1 ]
Miro, Manuel [2 ]
Richter, Pablo [1 ]
机构
[1] Univ Chile, Fac Chem & Pharmaceut Sci, Dept Inorgan & Analyt Chem, Santiago, Chile
[2] Univ Balearic Isl, Fac Sci, Dept Chem, FI TRACE Grp, E-07122 Palma de Mallorca, Spain
关键词
Automation; Dynamic microextraction; Rotating disk sorptive extraction; Non-steroidal anti-inflammatory drugs; Urine; NONSTEROIDAL ANTIINFLAMMATORY DRUGS; SOLID-PHASE MICROEXTRACTION; CHROMATOGRAPHY-MASS SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; WASTE-WATER SAMPLES; LAB-ON-VALVE; DICLOFENAC; IBUPROFEN; SORBENTS; SURFACE;
D O I
10.1016/j.chroma.2014.09.079
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel automatic sorptive microextraction approach combining sequential injection-based programmable flow with rotating disk sorptive extraction (RDSE) is proposed for the clean-up and concentration of low polarity organic species in urine samples. Non-steroidal anti-inflammatory drugs (NSAIDs), namely, ketoprofen, naproxen, diclofenac and ibuprofen, were selected as model analytes in a proof-of-concept design, and they were further determined by liquid chromatographic (LC) assays. The extracting phase consisted of octadecyl (C-18) chemically bonded silica embedded in a polytetrafluoroethylene (PTFE) substrate. The thin film was immobilized onto the surface of an in-house prepared rotating PTFE disk in a dedicated flow-through chamber. The programmable flow-based microextraction method operates under kinetic principles and features software-controlled sample loading and dynamic sorptive unidirectional-flow microextraction for as little as 10 min, followed by matrix clean-up and in-line elution with methanol. The hydrophobic thin-film extracting phase was demonstrated to be reusable for at least 15 consecutive extractions in urine without removing or changing the disk. The relative recoveries of the NSAIDs in urine ranged from 101 to 106% using a matrix-matched calibration curve, with extraction efficiencies of 30-38% using a dynamic regime, an enrichment factor of approximately 17 for 10 mL sample and relative standard deviations (RSD) between 3 and 6%. The detection limits (3 x S/N ratio) of the in-line sample preparation method coupled to LC-UV detection ranged from 0.022 to 0.044 mg L-1. Using NSAID monitored in urine from individuals who received oral administration of ibuprofen and diclofenac, the automatic sample handling method was proven to be efficient for urine clean-up and the determination of acidic drugs at biologically relevant levels. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 69
页数:6
相关论文
共 41 条
[1]   Stir Membrane Extraction: A Useful Approach for Liquid Sample Pretreatment [J].
Alcudia-Leon, M. C. ;
Lucena, R. ;
Cardenas, S. ;
Valcarcel, M. .
ANALYTICAL CHEMISTRY, 2009, 81 (21) :8957-8961
[2]   Determination of naproxen in human urine by solid-phase microextraction coupled to liquid chromatography [J].
Aresta, A ;
Palmisano, F ;
Zambonin, CG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (3-4) :643-647
[3]  
Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
[4]  
2-4
[5]   Online Hyphenation of Multimodal Microsolid Phase Extraction Involving Renewable Molecularly Imprinted and Reversed-Phase Sorbents to Liquid Chromatography for Automatic Multiresidue Assays [J].
Boonjob, Warunya ;
Yu, Yongliang ;
Miro, Manuel ;
Segundo, Marcela A. ;
Wang, Jianhua ;
Cerda, Victor .
ANALYTICAL CHEMISTRY, 2010, 82 (07) :3052-3060
[6]   DICLOFENAC SODIUM - A REVIEW OF ITS PHARMACOLOGICAL PROPERTIES AND THERAPEUTIC USE IN RHEUMATIC DISEASES AND PAIN OF VARYING ORIGIN [J].
BROGDEN, RN ;
HEEL, RC ;
PAKES, GE ;
SPEIGHT, TM ;
AVERY, GS .
DRUGS, 1980, 20 (01) :24-48
[7]   Thin-film microextraction [J].
Bruheim, I ;
Liu, XC ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :1002-1010
[8]  
Bushra Rabia, 2010, Oman Med J, V25, P155, DOI 10.5001/omj.2010.49
[9]   A new rotating-disk sorptive extraction mode, with a copolymer of divinylbenzene and N-vinylpyrrolidone trapped in the cavity of the disk, used for determination of florfenicol residues in porcine plasma [J].
Canas, Alejandro ;
Valdebenito, Samuel ;
Richter, Pablo .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (08) :2205-2210
[10]   Solid-phase microextraction using octadecyl-bonded silica immobilized on the surface of a rotating disk: Determination of hexachlorobenzene in water [J].
Canas, Alejandro ;
Richter, Pablo .
ANALYTICA CHIMICA ACTA, 2012, 743 :75-79