The Use of U-Net Lite and Extreme Gradient Boost (XGB) for Glaucoma Detection

被引:18
作者
Afolabi, Oluwatobi Joshua [1 ]
Mabuza-Hocquet, Gugulethu P. [2 ]
Nelwamondo, Fulufhelo V. [3 ,4 ]
Paul, Babu Sena [4 ]
机构
[1] Univ Johannesburg, Dept Elect Engn Sci, ZA-2006 Johannesburg, South Africa
[2] CSIR, Def & Secur, ZA-0001 Pretoria, South Africa
[3] CSIR, Nextgen Enterprises & Inst, ZA-0001 Pretoria, South Africa
[4] Univ Johannesburg, Inst Intelligent Syst, ZA-2006 Johannesburg, South Africa
关键词
Optical imaging; Image segmentation; Optical fibers; Computational modeling; Optical filters; Databases; Adaptive optics; Fundus image; glaucoma; segmentation; U-Net; OPTIC DISC; CUP SEGMENTATION; NETWORK; FUNDUS; IDENTIFICATION; PREVALENCE; DIAGNOSIS;
D O I
10.1109/ACCESS.2021.3068204
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Glaucoma has been credited to be the foremost cause of preventable loss of sight in the world second only to cataract. Its effect on the eye is usually irreversible and can only be prevented by early detection. In this paper, we developed a glaucoma detection technique. This technique includes a modified U-Net model called 'U-Net lite' and an extreme gradient boost (XGB) algorithm. The novel U-Net lite model is designed to have fewer parameters than the original U-Net model. The U-Net lite's parameters are 40 times fewer than the original U-Net model which makes the proposed model faster and cheaper to train. The proposed model is utilized to segment both the optic cup and the optic disc from the fundus images. The extreme gradient boost algorithm is utilized to analyze extracted features from segmented optic cups and discs and hence detect glaucoma. The proposed U-Net lite model was both trained and tested on the DRIONS, DRISHTI-GS, RIM-ONE V2 and the RIM-ONE V3 databases. When tested for optic disc segmentation on the four databases, the model achieved the following average dice-scores: 0.96 on RIM-ONE V3, 0.97 on RIM-ONE V2, 0.96 on DRIONS, and 0.97 on DRISHTI-GS. The XGB algorithm achieved an accuracy of 88.6% and an AUC-ROC of 93.6 % in detecting glaucoma from the RIM-ONE V3 and DRISHTI-GS database. The proposed glaucoma detection technique achieves a state-of-the-art accuracy and is useful for observing structural changes in an optic cup and optic disc.
引用
收藏
页码:47411 / 47424
页数:14
相关论文
共 77 条
  • [1] Ahmad H, 2014, 2014 INTERNATIONAL CONFERENCE ON ROBOTICS AND EMERGING ALLIED TECHNOLOGIES IN ENGINEERING (ICREATE), P321, DOI 10.1109/iCREATE.2014.6828388
  • [2] Dense Fully Convolutional Segmentation of the Optic Disc and Cup in Colour Fundus for Glaucoma Diagnosis
    Al-Bander, Baidaa
    Williams, Bryan M.
    Al-Nuaimy, Waleed
    Al-Taee, Majid A.
    Pratt, Harry
    Zheng, Yalin
    [J]. SYMMETRY-BASEL, 2018, 10 (04):
  • [3] Robust Concurrent Detection of Salt Domes and Faults in Seismic Surveys Using an Improved UNet Architecture
    Alfarhan, Mustafa
    Deriche, Mohamed
    Maalej, Ahmed
    [J]. IEEE ACCESS, 2022, 10 : 39424 - 39435
  • [4] Almazroa A. A., 2018, P SPIE, V6
  • [5] [Anonymous], 2012, P 2012 INT C COMPUTE, DOI DOI 10.1109/ICCCI.2012.6158789
  • [6] Calkins H, 2017, J ARRYTHM, V33, P369, DOI 10.1016/j.joa.2017.08.001
  • [7] Identification of the optic nerve head with genetic algorithms
    Carmona, Enrique J.
    Rincon, Mariano
    Garcia-Feijoo, Julian
    Martinez-de-la-Casa, Jose M.
    [J]. ARTIFICIAL INTELLIGENCE IN MEDICINE, 2008, 43 (03) : 243 - 259
  • [8] CellProfiler: image analysis software for identifying and quantifying cell phenotypes
    Carpenter, Anne E.
    Jones, Thouis Ray
    Lamprecht, Michael R.
    Clarke, Colin
    Kang, In Han
    Friman, Ola
    Guertin, David A.
    Chang, Joo Han
    Lindquist, Robert A.
    Moffat, Jason
    Golland, Polina
    Sabatini, David M.
    [J]. GENOME BIOLOGY, 2006, 7 (10)
  • [9] Chaurasia A, 2017, 2017 IEEE VISUAL COMMUNICATIONS AND IMAGE PROCESSING (VCIP)
  • [10] Superpixel Classification Based Optic Disc and Optic Cup Segmentation for Glaucoma Screening
    Cheng, Jun
    Liu, Jiang
    Xu, Yanwu
    Yin, Fengshou
    Wong, Damon Wing Kee
    Tan, Ngan-Meng
    Tao, Dacheng
    Cheng, Ching-Yu
    Aung, Tin
    Wong, Tien Yin
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (06) : 1019 - 1032