Generator-produced rubidium-82 positron emission tomography myocardial perfusion imaging-From basic aspects to clinical applications

被引:40
|
作者
Yoshinaga, Keiichiro [1 ]
Klein, Ran [2 ,3 ]
Tamaki, Nagara [2 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Mol Imaging, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Dept Nucl Med, Sapporo, Hokkaido 0608638, Japan
[3] Univ Ottawa, Inst Heart, Natl Cardiac PET Ctr, Ottawa, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Generator; Myocardial blood flow; Positron emission tomography; Rubidium; CORONARY-ARTERY-DISEASE; BLOOD-FLOW; DIAGNOSTIC-ACCURACY; EXTERNAL DETECTORS; PROGNOSTIC VALUE; PET; QUANTIFICATION; HEART; DIPYRIDAMOLE; FRACTION;
D O I
10.1016/j.jjcc.2010.01.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiovascular disease is the leading cause of death in modern industrialized countries with an aging population. This fact has fueled the need for innovative diagnostic testing intended to improve coronary artery disease (CAD) patient care Detection of myocardial ischemia using myocardial perfusion imaging (MPI) plays an important role for CAD diagnosis and the prediction of future risk of cardiovascular events Positron emission tomography (PET) MPI has high diagnostic accuracy and can estimate regional myocardial blood flow (MBF) in patients with CAD. Rubidium-82 (Rb-82) is a generator-produced PET myocardial perfusion tracer and has been widely used in North America in clinical practice. Rb-82 PET has recently become available in some cardiovascular centers in Europe and Japan. Clinical trials are expected in both regions. Rb-82 PET has high diagnostic accuracy and recent data have shown its prognostic value. Thus, Rb-82 PET would greatly contribute to CAD patients' care. Rb-82 PET can also be used to quantify MBF. This review describes the current status of Rb-82 MPI from basic principles to clinical implications. This paper also highlights the recent development of MBF quantification using Rb-82 PET. (C) 2010 Japanese College of Cardiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:163 / 173
页数:11
相关论文
共 50 条
  • [11] INFARCTION SIZING AND MYOCARDIAL PERFUSION MEASUREMENTS USING RUBIDIUM-82 AND POSITRON EMISSION TOMOGRAPHY
    BUDINGER, TF
    YANO, Y
    DERENZO, SE
    HUESMAN, RH
    YEN, CK
    MOYER, BR
    SHERMAN, LG
    AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02): : 399 - 399
  • [12] PLANAR IMAGING OF MYOCARDIAL PERFUSION WITH RUBIDIUM-82, A POSITRON EMITTER
    GOLDSMITH, SJ
    COCHAVI, S
    STRASHUN, A
    TRAPPIER, A
    HOROWITZ, SF
    GORLIN, R
    OBRIEN, H
    CIRCULATION, 1980, 62 (04) : 75 - 75
  • [13] MYOCARDIAL UPTAKE OF RUBIDIUM-82 USING POSITRON EMISSION TOMOGRAPHY
    BUDINGER, TF
    YANO, Y
    DERENZO, SE
    HUESMAN, RH
    CAHOON, JL
    MOYER, BR
    GREENBERG, WL
    OBRIEN, HA
    JOURNAL OF NUCLEAR MEDICINE, 1979, 20 (06) : 603 - 603
  • [14] Minimal starting time of data reconstruction for qualitative myocardial perfusion rubidium-82 positron emission tomography imaging
    van Dijk, Joris D.
    Huizing, Eline D.
    van Dalen, Jorn A.
    Timmer, Jorik R.
    Jager, Pieter L.
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (06) : 533 - 538
  • [15] The Incremental Prognostic Value of Myocardial Perfusion Parameters as Measured by Rubidium-82 Positron Emission Tomography
    Williams, Brent A.
    Merhige, Michael E.
    LaMonte, Michael J.
    Leonard, Deborah
    Greene, Robert
    Trevisan, Maurizio
    Dorn, Joan M.
    CIRCULATION, 2009, 120 (18) : S319 - S320
  • [16] Incremental Diagnostic Value of Regional Myocardial Blood Flow Quantification Over Relative Perfusion Imaging With Generator-Produced Rubidium-82 PET
    Yoshinaga, Keiichiro
    Katoh, Chietsugu
    Manabe, Osamu
    Klein, Ran
    Naya, Masanao
    Sakakibara, Mamoru
    Yamada, Shiro
    deKemp, Robert A.
    Tsutsui, Hiroyuki
    Tamaki, Nagara
    CIRCULATION JOURNAL, 2011, 75 (11) : 2628 - 2634
  • [17] DIAGNOSTIC ACCURACY OF QUANTITATIVE RUBIDIUM-82 POSITRON EMISSION TOMOGRAPHY MYOCARDIAL PERFUSION IMAGING: VALIDATION WITH INVASIVE CORONARY ANGIOGRAPHY
    Nakazato, Ryo
    Slomka, Piotr J.
    Hayes, Sean W.
    Cheng, Victor Y.
    Fermin, Jimmy S.
    Thomson, Louise E. J.
    Friedman, John D.
    Germano, Guido
    Berman, Daniel S.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E652 - E652
  • [18] Comparison of treadmill exercise versus dipyridamole stress with myocardial perfusion imaging using rubidium-82 positron emission tomography
    Chow, BJW
    Ananthasubramaniam, K
    deKemp, RA
    Dalipaj, MM
    Beanlands, RSB
    Ruddy, TD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (08) : 1227 - 1234
  • [19] Effect of proton pump inhibitors on Rubidium-82 gastric uptake using positron emission tomography myocardial perfusion imaging
    Atif H. Alzahrani
    Punitha Arasaratnam
    Samia Massalha
    Ali Alenazy
    Alex Lee
    Owen Clarkin
    Robert A deKemp
    Alomgir Hossain
    Rob S. Beanlands
    Terrence D. Ruddy
    Benjamin J. W. Chow
    Journal of Nuclear Cardiology, 2020, 27 : 1443 - 1451
  • [20] Rubidium-82 positron emission tomography myocardial perfusion imaging - How accurate is it for detection of multi-vessels disease?
    Shah, Anu R.
    Kokkirala, Aravind
    Rabadiya, Vimal
    Yarlagadda, Anitha
    Kattan, Deborah
    Ahriberg, Alan
    Heller, Gary V.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A172 - A173