Generator-produced rubidium-82 positron emission tomography myocardial perfusion imaging-From basic aspects to clinical applications

被引:40
|
作者
Yoshinaga, Keiichiro [1 ]
Klein, Ran [2 ,3 ]
Tamaki, Nagara [2 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Mol Imaging, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Dept Nucl Med, Sapporo, Hokkaido 0608638, Japan
[3] Univ Ottawa, Inst Heart, Natl Cardiac PET Ctr, Ottawa, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Generator; Myocardial blood flow; Positron emission tomography; Rubidium; CORONARY-ARTERY-DISEASE; BLOOD-FLOW; DIAGNOSTIC-ACCURACY; EXTERNAL DETECTORS; PROGNOSTIC VALUE; PET; QUANTIFICATION; HEART; DIPYRIDAMOLE; FRACTION;
D O I
10.1016/j.jjcc.2010.01.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiovascular disease is the leading cause of death in modern industrialized countries with an aging population. This fact has fueled the need for innovative diagnostic testing intended to improve coronary artery disease (CAD) patient care Detection of myocardial ischemia using myocardial perfusion imaging (MPI) plays an important role for CAD diagnosis and the prediction of future risk of cardiovascular events Positron emission tomography (PET) MPI has high diagnostic accuracy and can estimate regional myocardial blood flow (MBF) in patients with CAD. Rubidium-82 (Rb-82) is a generator-produced PET myocardial perfusion tracer and has been widely used in North America in clinical practice. Rb-82 PET has recently become available in some cardiovascular centers in Europe and Japan. Clinical trials are expected in both regions. Rb-82 PET has high diagnostic accuracy and recent data have shown its prognostic value. Thus, Rb-82 PET would greatly contribute to CAD patients' care. Rb-82 PET can also be used to quantify MBF. This review describes the current status of Rb-82 MPI from basic principles to clinical implications. This paper also highlights the recent development of MBF quantification using Rb-82 PET. (C) 2010 Japanese College of Cardiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:163 / 173
页数:11
相关论文
共 50 条
  • [1] QUANTIFICATION OF MYOCARDIAL FLOW WITH RUBIDIUM-82, A GENERATOR-PRODUCED POSITRON EMITTER
    GOLDSTEIN, RA
    MULLANI, NA
    FISHER, DJ
    GOULD, KL
    CLINICAL RESEARCH, 1982, 30 (02): : A190 - A190
  • [2] Feasibility of exercise rubidium-82 positron emission tomography myocardial perfusion imaging
    Chow, BJ
    Ruddy, TD
    Dalipaj, MM
    de Kemp, RA
    Nadeau, C
    Ukkonen, H
    Ananthasubramaniam, K
    Beanlands, RS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 428A - 428A
  • [3] Myocardial perfusion scintigraphy using rubidium-82 positron emission tomography
    Arumugam, Parthiban
    Tout, Deborah
    Tonge, Christine
    BRITISH MEDICAL BULLETIN, 2013, 107 (01) : 87 - 100
  • [4] Metastatic breast cancer diagnosed by rubidium-82 positron emission tomography myocardial perfusion imaging
    Shafiq, Ali
    Ammar, Khawaja Afzal
    Gilles, Lynn
    Machernis, Nolan
    Mahlum, Debra
    Chareonthaitawee, Panithaya
    Port, Steven C.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (03) : 1048 - 1050
  • [5] What is the prognostic value of myocardial perfusion imaging using rubidium-82 positron emission tomography?
    Yoshinaga, Keiichiro
    Chow, Benjamin J. W.
    Williams, Kathryn
    Chen, Li
    deKemp, Robert A.
    Garrard, Linda
    Szeto, Alexander Lok-Tin
    Aung, May
    Davies, Ross A.
    Ruddy, Terrence D.
    Beanlands, Rob S. B.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (05) : 1029 - 1039
  • [6] Metastatic breast cancer diagnosed by rubidium-82 positron emission tomography myocardial perfusion imaging
    Ali Shafiq
    Khawaja Afzal Ammar
    Lynn Gilles
    Nolan Machernis
    Debra Mahlum
    Panithaya Chareonthaitawee
    Steven C. Port
    Journal of Nuclear Cardiology, 2018, 25 : 1048 - 1050
  • [7] The Prognostic Value of Mild Perfusion Defects as Identified by Rubidium-82 Positron Emission Tomography Myocardial Perfusion Imaging
    Williams, Brent A.
    Merhige, Michael
    LaMonte, Michael
    Donahue, Richard
    Trevisan, Maurizio
    Dorn, Joan
    CIRCULATION, 2010, 122 (21)
  • [8] Prognostic Value of Splenic Response Ratio in Rubidium-82 Positron Emission Tomography Myocardial Perfusion Imaging
    Bami, Karan
    Tewari, Shrankhala
    Guirguis, Fadi
    Garrard, Linda
    Guo, Ann
    Ruddy, Terrence D.
    Beanlands, Robert S.
    deKemp, Robert A.
    Chow, Benjamin J.
    Dwivedi, Girish
    CIRCULATION, 2016, 134
  • [9] Prognostic value of transient ischemic dilation on Rubidium-82 positron emission tomography myocardial perfusion imaging
    Patel, Krishna K.
    Lim, Phillip
    Peri-Okonny, Poghni A.
    Singh, Annapoorna
    Mcghie, A. Iain
    Sabharwal, Basera
    Agarwal, Vikram
    Shaw, Leslee J.
    Bateman, Timothy M.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2025, 44
  • [10] Manufacture of strontium-82/rubidium-82 generators and quality control of rubidium-82 chloride for myocardial perfusion imaging in patients using positron emission tomography
    Alvarez-Diez, TM
    deKemp, R
    Beanlands, R
    Vincent, J
    APPLIED RADIATION AND ISOTOPES, 1999, 50 (06) : 1015 - 1023