An online x-ray based position validation system for prostate hypofractionated radiotherapy

被引:20
作者
Arumugam, Sankar [1 ,2 ]
Sidhom, Mark [3 ]
Xing, Aitang [1 ,2 ]
Holloway, Lois [1 ,2 ,4 ,5 ,6 ]
机构
[1] Liverpool & Macarthur Canc Therapy Ctr, Dept Med Phys, Liverpool, NSW 2170, Australia
[2] Ingham Inst, Liverpool, NSW 2170, Australia
[3] Liverpool & Macarthur Canc Therapy Ctr, Dept Radiat Oncol, Liverpool, NSW 2170, Australia
[4] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
[5] Univ New S Wales, South Western Clin Sch, Sydney, NSW 2052, Australia
[6] Univ Sydney, Inst Med Phys, Sch Phys, Sydney, NSW 2006, Australia
关键词
SBRT; autosegmentation; online monitoring; monoscopic image; STEREOTACTIC BODY RADIOTHERAPY; MOTION; LOCALIZATION; EXPERIENCE;
D O I
10.1118/1.4940351
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Accurate positioning of the target volume during treatment is paramount for stereotactic body radiation therapy (SBRT). In this work, the authors present the development of an in-house software tool to verify target position with an Elekta-Synergy linear accelerator using kV planar images acquired during treatment delivery. Methods: In-house software, SeedTracker, was developed in MATLAB to perform the following three functions: 1. predict intended seed positions in a planar view perpendicular to any gantry angle, simulating a portal imaging device, from the 3D seed co-ordinates derived from the treatment planning system; 2. autosegment seed positions in kV planar images; and 3. report the position shift based on the seed positions in the projection images. The performance of SeedTracker was verified using a CIRS humanoid phantom (CIRS, VA, USA) implanted with three Civco gold seed markers (Civco, IA, USA) in the prostate. The true positive rate of autosegmentation (TPR g) and the accuracy of the software in alerting the user when the isocenter position was outside the tolerance (TPRtng) were studied. Two-dimensional and 3D static position offsets introduced to the humanoid phantom and 3D dynamic offsets introduced to a gel phantom containing gold seeds were used for evaluation of the system. Results: SeedTracker showed a TPR g of 100% in the humanoid phantom for projection images acquired at all angles except in the ranges of 80-100 and 260-280 where seeds are obscured by anatomy. This resulted in a TPRtrig of 88% over the entire treatment range for considered 3D static offsets introduced to the phantom. For 2D static offsets where the position offsets were only introduced in the anterior posterior and lateral directions, the TPRtrig of SeedTracker was limited by both seed detectability and positional offset. SeedTracker showed a false positive trigger in the projection angle range between 130-170 and 310-350 (a maximum of 24% of treatment time) due to limited information that can be derived from monoscopic images. The system accurately determined the dynamic trajectory of the isocenter position in the superior and inferior direction for the studied dynamic offset scenarios based on the seed position in monoscopic images Conclusions: The developed software has been shown to accurately autosegment the seed positions in kV planar images except for two 20 arcs where seeds are obscured by anatomical structures. The isocenter trajectories determined by the system, based on the monoscopic images, provide useful information for monitoring the prostate position. The developed system has potential application for monitoring prostate position during treatment delivery in linear accelerator based SBRT. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:961 / 974
页数:14
相关论文
共 26 条
  • [1] CyberKnife Stereotactic Radiotherapy as Monotherapy for Low- to Intermediate-Stage Prostate Cancer: Early Experience, Feasibility, and Tolerance
    Aluwini, Shafak
    van Rooij, Peter
    Hoogeman, Misha
    Bangma, Chris
    Kirkels, Wim J.
    Incrocci, Luca
    Kolkman-Deurloo, Inger-Karine
    [J]. JOURNAL OF ENDOUROLOGY, 2010, 24 (05) : 865 - 869
  • [2] Accuracy of a wireless localization system for radiotherapy
    Balter, JM
    Wright, JN
    Newell, LJ
    Friemel, B
    Dimmer, S
    Cheng, Y
    Wong, J
    Vertatschitsch, E
    Mate, TP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03): : 933 - 937
  • [3] A monoscopic method for real-time tumour tracking using combined occasional x-ray imaging and continuous respiratory monitoring
    Cho, Byungchul
    Suh, Yelin
    Dieterich, Sonja
    Keall, Paul J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (11) : 2837 - 2855
  • [4] PROSTATE MOTION DURING STANDARD RADIOTHERAPY AS ASSESSED BY FIDUCIAL MARKERS
    CROOK, JM
    RAYMOND, Y
    SALHANI, D
    YANG, H
    ESCHE, B
    [J]. RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) : 35 - 42
  • [5] Relationship of Imaging Frequency and Planning Margin to Account for Intrafraction Prostate Motion: Analysis Based on Real-Time Monitoring Data
    Curtis, William
    Khan, Mohammad
    Magnelli, Anthony
    Stephans, Kevin
    Tendulkar, Rahul
    Xia, Ping
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (03): : 700 - 706
  • [6] DAILY IMAGE GUIDANCE WITH CONE-BEAM COMPUTED TOMOGRAPHY FOR HEAD-AND-NECK CANCER INTENSITY-MODULATED RADIOTHERAPY: A PROSPECTIVE STUDY
    Den, Robert B.
    Doemer, Anthony
    Kubicek, Greg
    Bednarz, Greg
    Galvin, James M.
    Keane, William M.
    Xiao, Ying
    Machtay, Mitchell
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (05): : 1353 - 1359
  • [7] Position detection accuracy of a novel linac-mounted intrafractional x-ray imaging system
    Fast, Martin F.
    Krauss, Andreas
    Oelfke, Uwe
    Nill, Simeon
    [J]. MEDICAL PHYSICS, 2012, 39 (01) : 109 - 118
  • [8] Stereotactic body radiotherapy for low-risk prostate cancer: five-year outcomes
    Freeman, Debra E.
    King, Christopher R.
    [J]. RADIATION ONCOLOGY, 2011, 6
  • [9] Stereotactic Body Radiotherapy: An Emerging Treatment Approach for Localized Prostate Cancer
    Friedland, Jay L.
    Freeman, Debra E.
    Masterson-McGary, Mary Ellen
    Spellberg, David M.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2009, 8 (05) : 387 - 392
  • [10] Intrafraction prostate motion during IMRT for prostate cancer
    Huang, E
    Dong, L
    Chandra, A
    Kuban, DA
    Rosen, II
    Evans, A
    Pollack, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (02): : 261 - 268