Intraoperative three-dimensional navigation for pedicle screw placement

被引:31
作者
Grützner, PA
Beutler, T
Wendl, K
von Recum, J
Wentzensen, A
Nolte, LP
机构
[1] Heidelberg Univ, Klin Unfall & Wiederherstellungschirurg, Berufsgenossensch Unfallklin Ludwigshafen, D-67071 Ludwigshafen, Germany
[2] Univ Bern, ME Muller Res Ctr Orthopaed Surg, Inst Surg Technol & Biomechan, CH-3012 Bern, Switzerland
来源
CHIRURG | 2004年 / 75卷 / 10期
关键词
computer-assisted surgery; intraoperative imaging; SIREMOBIL Iso-C-3D; C-arm; navigation; pedicle screw;
D O I
10.1007/s00104-004-0944-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
The mobile SIREMOBIL iso-C-3D C-arm (Siemens, Erlangen, Germany) is the first device permitting intraoperative, three-dimensional representation of bone structures. A high-resolution, isotropic 3D data cube in the isocenter with sides of approximately 12 cm is calculated simultaneously. The SIREMOBIL Iso-C-3D is linked to the navigation system. This makes it possible to transfer the generated 3D data directly to the linked navigation system without the need for surgeon-dependent registration. In this prospective clinical trial, we evaluated the accuracy of pedicle screw placement using this device. In 61 patients, a total of 302 pedicle screws were placed. Only in five cases (1.7%) were misplacements of >2 mm shown in postoperative control CT. The average fluoroscopy time was 1.28 +/- 0.56 min, and the average operative duration was 103.26 +/- 23.3 min. There were no postoperative neurological complications in any of the 30 patients. From these data, we conclude that Iso-C-3D navigation is a very accurate method for the placement of pedicle screws.
引用
收藏
页码:967 / 975
页数:13
相关论文
共 37 条
[31]   Evaluation of pedicle screw position in thoracic and lumbar spine fixation using plain radiographs and computed tomography - A prospective study of 35 patients [J].
Sapkas, GS ;
Papadakis, SA ;
Stathakopoulos, DP ;
Papagelopoulos, PJ ;
Badekas, AC ;
Kaiser, JH .
SPINE, 1999, 24 (18) :1926-1929
[32]   Computer-assisted spine surgery [J].
Schlenzka, D ;
Laine, T ;
Lund, T .
EUROPEAN SPINE JOURNAL, 2000, 9 (Suppl 1) :S57-S64
[33]   Clinical relevance of accuracy of pedicle screw placement - A computed tomographic-supported analysis [J].
Schulze, CJ ;
Munzinger, E ;
Weber, U .
SPINE, 1998, 23 (20) :2215-2220
[34]   Accuracy of computer-assisted pedicle screw placement - An in vivo computed tomography analysis [J].
Schwarzenbach, O ;
Berlemann, U ;
Jost, B ;
Visarius, H ;
Arm, E ;
Langlotz, F ;
Nolte, LP ;
Ozdoba, C .
SPINE, 1997, 22 (04) :452-458
[35]  
Ugur HÇ, 2001, J SPINAL DISORD, V14, P39
[36]   SPINAL PEDICLE FIXATION - RELIABILITY AND VALIDITY OF ROENTGENOGRAM-BASED ASSESSMENT AND SURGICAL FACTORS ON SUCCESSFUL SCREW PLACEMENT [J].
WEINSTEIN, JN ;
SPRATT, KF ;
SPENGLER, D ;
BRICK, C ;
REID, S .
SPINE, 1988, 13 (09) :1012-1018
[37]   ANALYSIS OF THE MORPHOMETRIC CHARACTERISTICS OF THE THORACIC AND LUMBAR PEDICLES [J].
ZINDRICK, MR ;
WILTSE, LL ;
DOORNIK, A ;
WIDELL, EH ;
KNIGHT, GW ;
PATWARDHAN, AG ;
THOMAS, JC ;
ROTHMAN, SL ;
FIELDS, BT .
SPINE, 1987, 12 (02) :160-166