Bioluminescence tomography based on the phase approximation model

被引:12
|
作者
Cong, W. [1 ]
Wang, G. [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Biomed Imaging Div, Sch Biomed Engn & Sci, Blacksburg, VA 24061 USA
关键词
OPTICAL TOMOGRAPHY; RADIATIVE-TRANSFER; LIGHT; RECONSTRUCTION; PROPAGATION; EQUATION; TISSUES; GENE;
D O I
10.1364/JOSAA.27.000174
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A reconstruction method of bioluminescence sources is proposed based on a phase approximation model. Compared with the diffuse approximation, this phase approximation model more correctly predicts bioluminescence photon propagation in biological tissues, so that bioluminescence tomography can accurately locate and quantify the distribution of bioluminescence sources. The compressive sensing ( CS) technique is applied to regularize the inverse source reconstruction to enhance numerical stability and efficiency. The numerical simulation and phantom experiments demonstrate the feasibility of the proposed approach. (C) 2010 Optical Society of America
引用
收藏
页码:174 / 179
页数:6
相关论文
共 50 条
  • [1] Numerical approximation of bioluminescence tomography based on a new formulation
    Cheng, Xiaoliang
    Gong, Rongfang
    Han, Weimin
    JOURNAL OF ENGINEERING MATHEMATICS, 2009, 63 (01) : 121 - 133
  • [2] Differential Evolution Approach for Regularized Bioluminescence Tomography
    Cong, Alexander
    Cong, Wenxiang
    Lu, Yujie
    Santago, Peter
    Chatziioannou, Arion
    Wang, Ge
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (09) : 2229 - 2238
  • [3] Determining sources in the bioluminescence tomography problem
    Ding, Ming-Hui
    Gong, Rongfang
    Liu, Hongyu
    Lo, Catharine W. K.
    INVERSE PROBLEMS, 2024, 40 (12)
  • [4] Spectrally resolved bioluminescence tomography with the third-order simplified spherical harmonics approximation
    Lu, Yujie
    Douraghy, Ali
    Machado, Hidevaldo B.
    Stout, David
    Tian, Jie
    Herschman, Harvey
    Chatziioannou, Arion F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (21) : 6477 - 6493
  • [5] An efficient forward model based on the Lattice Boltzmann method for optical tomography
    Cen, Xingxing
    Yan, Zhuangzhi
    Jiang, Jiehui
    Wu, Huandi
    OPTIK, 2020, 200
  • [6] Three-dimensional Bioluminescence Tomography based on Bayesian Approach
    Feng, Jinchao
    Jia, Kebin
    Qin, Chenghu
    Yan, Guorui
    Zhu, Shouping
    Zhang, Xing
    Liu, Junting
    Tian, Jie
    OPTICS EXPRESS, 2009, 17 (19): : 16834 - 16848
  • [7] A fast solver for an inverse problem arising in bioluminescence tomography
    Gong, Rongfang
    Cheng, Xiaoliang
    Han, Weimin
    JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2014, 267 : 228 - 243
  • [8] A multi-phase level set framework for source reconstruction in bioluminescence tomography
    Huang, Heyu
    Qu, Xiaochao
    Liang, Jimin
    He, Xiaowei
    Chen, Xueli
    Yang, Da'an
    Tian, Jie
    JOURNAL OF COMPUTATIONAL PHYSICS, 2010, 229 (13) : 5246 - 5256
  • [9] A gantry-based tri-modality system for bioluminescence tomography
    Yan, Han
    Lin, Yuting
    Barber, William C.
    Unlu, Mehmet Burcin
    Gulsen, Gultekin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (04)
  • [10] In Vivo Mouse Bioluminescence Tomography with Radionuclide-Based Imaging Validation
    Lu, Yujie
    Machado, Hidevaldo B.
    Bao, Qinan
    Stout, David
    Herschman, Harvey
    Chatziioannou, Arion F.
    MOLECULAR IMAGING AND BIOLOGY, 2011, 13 (01) : 53 - 58