Comparison of the precision of two vertebral morphometry programs for the Lunar EXPERT-XL imaging densitometer

被引:18
|
作者
Harvey, SB
Hutchison, KM
Rennie, EC
Hukins, DWL
Reid, DM
机构
[1] Univ Aberdeen, Dept Biomed Phys & Bioengn, Aberdeen AB25 2ZD, Scotland
[2] Aberdeen Royal Hosp, Osteoporosis Res Unit, Aberdeen AB25 1GR, Scotland
来源
BRITISH JOURNAL OF RADIOLOGY | 1998年 / 71卷 / 844期
关键词
D O I
10.1259/bjr.71.844.9659132
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Comparative precision tests of the vertebral height measurement function of the Aberdeen Vertebral Morphometry System (AVMS) software and Lunar EXPERT-XL software were undertaken using four vertebrae from the same lateral spine dual energy X-ray absorptiometry (DXA) image of the same subject (male, 67 years). Two of the vertebrae were abnormal and two were normal. Three observers inexperienced in morphometry and one experienced observer took part in the study, Repeatability was obtained from IO sequential measurements of the posterior, middle and anterior heights at the same sitting by the same observer. Intraobserver reproducibility compared the means of one set of measurements for all vertebrae with another taken 1 week later. Interobserver reproducibility compared the means of one set of measurements for all vertebrae from an experienced and an inexperienced observer, and from two inexperienced observers. The AVMS software had significantly higher (p<0.05) repeatability (mean coefficient of variability, CV = 3.5%) than the Lunar software (mean CV = 5%), significantly higher (p < 0.01) intraobserver reproducibility (mean CV = 4.6%) than the Lunar software (mean CV = 8.5%), and significantly higher (p < 0.05) interobserver reproducibility (mean CV = 4.7%) than the Lunar software (mean CV = 7.5%). In conclusion, the new AVMS method possessed higher precision when measuring both abnormal and normal vertebrae and when used by both experienced and inexperienced observers.
引用
收藏
页码:388 / 398
页数:11
相关论文
共 23 条
  • [11] A phantom based study on the effect of subject positioning on morphometric X-ray absorptiometry using the Lunar EXPERT-XL
    Thorpe, JA
    Steel, SA
    Langton, CM
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (851): : 1153 - 1161
  • [12] Vertebral morphometry: A direct comparison of MXA and MRX precision.
    Rea, JA
    Chen, MB
    Li, J
    Blake, GM
    Steiger, P
    Genant, HK
    Fogelman, I
    JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 : S494 - S494
  • [13] Serial hand done densitometry with lunar-xl expert densitometer in the assessment of patients with very early inflammatory arthritis.
    Green, MJ
    Proudman, S
    Stewart, S
    Wakefield, RJ
    McGonagle, D
    Smith, MA
    Emery, P
    ARTHRITIS AND RHEUMATISM, 1997, 40 (09): : 1565 - 1565
  • [14] Inter-observer variation of vertebral morphometry using two different DXA methodologies: Expert vs prodigy
    Pearson, D
    Horton, B
    Green, DJ
    Hosking, DJ
    Goodby, SA
    Steel, SA
    JOURNAL OF BONE AND MINERAL RESEARCH, 2004, 19 : S367 - S367
  • [15] Vertebral morphometry: A comparison of long-term precision of morphometric X-ray absorptiometry and morphometric radiography in normal and osteoporotic subjects
    Rea, JA
    Chen, MB
    Li, J
    Marsh, E
    Fan, B
    Blake, GM
    Steiger, P
    Smith, IG
    Genant, HK
    Fogelman, I
    OSTEOPOROSIS INTERNATIONAL, 2001, 12 (02) : 158 - 166
  • [16] Vertebral Morphometry: A Comparison of Long-Term Precision of Morphometric X-ray Absorptiometry and Morphometric Radiography in Normal and Osteoporotic Subjects
    J. A. Rea
    M. B. Chen
    J. Li
    E. Marsh
    B. Fan
    G. M. Blake
    P. Steiger
    I. G. Smith
    H. K. Genant
    I. Fogelman
    Osteoporosis International, 2001, 12 : 158 - 166
  • [17] Comparison of two computer-animated imaging programs for quantifying facial profile preference
    Giddon, DB
    Bernier, DL
    Evans, CA
    Kinchen, JA
    PERCEPTUAL AND MOTOR SKILLS, 1996, 82 (03) : 1251 - 1264
  • [18] Comparison of precision and accuracy of linear measurements performed by two different imaging software programs and obtained from 3D-CBCT images for Le Fort I osteotomy
    Gaia, B. F.
    Pinheiro, L. R.
    Umetsubo, O. S.
    Costa, F. F.
    Cavalcanti, M. G. P.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (05)
  • [19] Automated versus manual imaging assessment of early ischemic changes in acute stroke: comparison of two software packages and expert consensus
    Friederike Austein
    Fritz Wodarg
    Nora Jürgensen
    Monika Huhndorf
    Johannes Meyne
    Thomas Lindner
    Olav Jansen
    Naomi Larsen
    Christian Riedel
    European Radiology, 2019, 29 : 6285 - 6292
  • [20] Automated versus manual imaging assessment of early ischemic changes in acute stroke: comparison of two software packages and expert consensus
    Austein, Friederike
    Wodarg, Fritz
    Juergensen, Nora
    Huhndorf, Monika
    Meyne, Johannes
    Lindner, Thomas
    Jansen, Olav
    Larsen, Naomi
    Riedel, Christian
    EUROPEAN RADIOLOGY, 2019, 29 (11) : 6285 - 6292