摘要
Comparative precision tests of the vertebral height measurement function of the Aberdeen Vertebral Morphometry System (AVMS) software and Lunar EXPERT-XL software were undertaken using four vertebrae from the same lateral spine dual energy X-ray absorptiometry (DXA) image of the same subject (male, 67 years). Two of the vertebrae were abnormal and two were normal. Three observers inexperienced in morphometry and one experienced observer took part in the study, Repeatability was obtained from IO sequential measurements of the posterior, middle and anterior heights at the same sitting by the same observer. Intraobserver reproducibility compared the means of one set of measurements for all vertebrae with another taken 1 week later. Interobserver reproducibility compared the means of one set of measurements for all vertebrae from an experienced and an inexperienced observer, and from two inexperienced observers. The AVMS software had significantly higher (p<0.05) repeatability (mean coefficient of variability, CV = 3.5%) than the Lunar software (mean CV = 5%), significantly higher (p < 0.01) intraobserver reproducibility (mean CV = 4.6%) than the Lunar software (mean CV = 8.5%), and significantly higher (p < 0.05) interobserver reproducibility (mean CV = 4.7%) than the Lunar software (mean CV = 7.5%). In conclusion, the new AVMS method possessed higher precision when measuring both abnormal and normal vertebrae and when used by both experienced and inexperienced observers.
引用
收藏
页码:388 / 398
页数:11
相关论文
共 23 条
  • [1] Improved vertebral morphometry precision using images from lunar EXPERT-XL bone densitometer
    Harvey, SB
    Hukins, DWL
    Hutchison, KM
    Rennie, EC
    Reid, DM
    JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 : T657 - T657
  • [2] A preliminary evaluation of the Lunar Expert-XL for bone densitometry and vertebral morphometry
    Lang, T
    Takada, M
    Gee, R
    Wu, C
    Li, J
    HayashiClark, C
    Schoen, S
    March, V
    Genant, HK
    JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (01) : 136 - 143
  • [3] Image Resolution of the Lunar Expert-XL
    J. A. Thorpe
    S. A. Steel
    Osteoporosis International, 1999, 10 : 95 - 101
  • [4] Vertebral morphometry: Repeat scan precision using the lunar Expert-XL and the hologic 4500A. A study for the 'WISDOM' RCT of hormone replacement therapy
    Crabtree, N
    Wright, J
    Walgrove, A
    Rea, J
    Hanratty, L
    Lunt, M
    Fogelman, I
    Palmer, R
    Vickers, M
    Compston, JE
    Reeve, J
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 (06) : 537 - 543
  • [5] Image resolution of the Lunar Expert-XL
    Thorpe, JA
    Steel, SA
    OSTEOPOROSIS INTERNATIONAL, 1999, 10 (02) : 95 - 101
  • [6] Vertebral Morphometry: Repeat Scan Precision Using the Lunar Expert-XL and the Hologic 4500A. A Study for the “WISDOM” RCT of Hormone Replacement Therapy
    N. Crabtree
    J. Wright
    A. Walgrove
    J. Rea
    L. Hanratty
    M. Lunt
    I. Fogelman
    R. Palmer
    M. Vickers
    J. E. Compston
    J. Reeve
    Osteoporosis International, 2000, 11 : 537 - 543
  • [7] An assessment of the radiation dose to patients and staff from a Lunar Expert-XL fan beam densitometer
    Steel, SA
    Baker, AJ
    Saunderson, JR
    PHYSIOLOGICAL MEASUREMENT, 1998, 19 (01) : 17 - 26
  • [8] Factors affecting accuracy of bone mineral density measurement using a Lunar Expert-XL fan beam densitometer
    Goodby, A
    Steel, SA
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 : 29 - 29
  • [9] The effect of tissue depth and scan mode on bone mineral density using a Lunar Expert-XL fan beam densitometer
    Goodby, A
    Steel, SA
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 : S44 - S44
  • [10] Pediatric total body and spine measurements with Lunar DPX and Lunar EXPERT-XL in a clinical setting.
    Lien, G
    Bollerslev, J
    Isaksen, GA
    Godang, K
    Forre, O
    JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 : S341 - S341