Measured Corneal Astigmatism Versus Pseudophakic Predicted Refractive Astigmatism in Cataract Surgery Candidates

被引:15
作者
Abulafia, Adi [1 ,6 ]
Barrett, Grahama D. [2 ,3 ]
Porat-Rein, Adi [1 ]
Tsessler, Maria [1 ]
Zadok, David [1 ]
Kan-Tor, Yoav [2 ,4 ]
Mourits, Maarten P. [5 ]
Lapid-Gortzak, Ruth [3 ,5 ]
机构
[1] Hebrew Univ Jerusalem, Dept Ophthalmol, Shaare Zedek Med Ctr, Jerusalem, Israel
[2] Univ Western Australia, Sir Charles Gairdner Hosp, Sir Charles Gairdner Hosp, Perth, WA, Australia
[3] Univ Western Australia, Lions Eye Inst, Perth, WA, Australia
[4] Hebrew Univ Jerusalem, Ctr Interdisciplinary Data Sci Res, Rachel & Selim Benin Sch Comp Sci & Engn, Edmond J Safra Campus Givat Ram, Jerusalem, Israel
[5] Univ Amsterdam, Dept Ophthalmol, Amsterdam UMC, AMC, Amsterdam, Netherlands
[6] Shaare Zedek Med Ctr, Dept Ophthalmol, Shmuel Bait St 12, IL-9103102 Jerusalem, Israel
关键词
INTRAOCULAR-LENS CALCULATIONS;
D O I
10.1016/j.ajo.2022.02.029
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare standard and total corneal astigmatism measurements to the predicted pseudopha-kic (nontoric) refractive astigmatism in candidates for cataract surgery. DESIGN: A retrospective, cross-sectional study. METHODS: A single-center analysis of consecutive eyes measured with a swept-source optical coherence tomography biometer at a large tertiary medical center between February 2018 and June 2020. Corneal astigmatism was calculated based on standard keratometry astigmatism (KA), total corneal astigmatism (TCA), and predicted refractive astigmatism (PRA) for a monofocal nontoric intraocular lens (IOL) implantation calculated by the Barrettoric calculator using the predicted posterior corneal astigmatism (PRA(Predicted-PCA) ) and the measured poste-rior corneal astigmatism (PRA(Measured-PCA) ) options. Separate analyses were performed for each eye. SETTING: Ophthalmology Department, Shaare Zedek Medical Center, Jerusalem, Israel. RESULTS: In total, 8152 eyes of 5320 patients (4221 right eyes [OD] and 3931 left eyes [OS], mean age 70.6 +/- 12.2 years, 54.2% females) were included in the study. The mean vector values (centroid) for KA, TCA, PRA(Predicted-PCA), and PRA(Measured-PCA) were 0.07 diopters [D] at 19.5 degrees, 0.27 D at 7.5 degrees, 0.44 D at 2.9 degrees, and 0.43 D at 179.3 degrees, respectively ( P < .01), for OD and 0.02 D at 150.3 degrees, 0.23 D at 169.7 degrees, 0.40 D at 179.4 degrees, and 0.42 D at 169.5 degrees, respectively ( P < .01), for OS. More than 73% of eyes had a PRA > 0.5 D. CONCLUSIONS: Standard and total corneal astigmatism measurements differ significantly from the PRA by the Barrett toric calculator. The PRA, rather than the KA or TCA, should be used as the reference guide for astigmatism correction with toric IOL implantation. (C) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 24 条
[1]   Comparison of corneal surgically induced astigmatism calculations based on keratometry measurements made by 2 biometric devices [J].
Abulafia, Adi ;
Rein, Adi Porat ;
Weill, Yishay ;
Zadok, David ;
Mourits, Maarten P. ;
Lapid-Gortzak, Ruth .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (12) :1542-1547
[2]   Pursuing perfection in intraocular lens calculations IV. Rethinking astigmatism analysis for intraocular lens-based surgery: Suggested terminology, analysis, and standards for outcome reports [J].
Abulafia, Adi ;
Koch, Douglas D. ;
Holladay, Jack T. ;
Wang, Li ;
Hill, Warren .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (10) :1169-1174
[3]   Comparison of Methods to Predict Residual Astigmatism After Intraocular Lens Implantation [J].
Abulafia, Adi ;
Hill, Warren E. ;
Franchina, Maria ;
Barrett, Graham D. .
JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (10) :699-+
[4]  
Barrett G, 2022, STEINERTS CATARACT S, V4th
[5]   Comparison of Methodologies Using Estimated or Measured Values of Total Corneal Astigmatism for Toric Intraocular Lens Power Calculation [J].
Ferreira, Tiago B. ;
Ribeiro, Paulo ;
Ribeiro, Filomena J. ;
O'Neill, Joao G. .
JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (12) :794-801
[6]   Ocular biometric measurements in cataract surgery candidates in Portugal [J].
Ferreira, Tiago B. ;
Hoffer, Kenneth J. ;
Ribeiro, Filomena ;
Ribeiro, Paulo ;
O'Neill, Joao G. .
PLOS ONE, 2017, 12 (10)
[7]   Prediction of postoperative intraocular lens tilt using swept-source optical coherence tomography [J].
Hirnschall, Nino ;
Buehren, Tobias ;
Bajramovic, Ferid ;
Trost, Michael ;
Teuber, Tanja ;
Findl, Oliver .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (06) :732-736
[8]   Analysis of biometry and prevalence data for corneal astigmatism in 23 239 eyes [J].
Hoffmann, Peter Christian ;
Huetz, Werner W. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (09) :1479-1485
[9]   Improving toric intraocular lens calculations using total surgically induced astigmatism for a 2.5 mm temporal incision [J].
Holladay, Jack T. ;
Pettit, George .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (03) :272-283
[10]   Analysis of aggregate surgically induced refractive change, prediction error, and intraocular astigmatism [J].
Holladay, JT ;
Moran, JR ;
Kezirian, GM .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (01) :61-79