Height control for small periodic structures using x-ray radiography

被引:3
作者
Schuettler, M. [1 ,2 ,3 ]
Meyer, P. [2 ,3 ]
Schaff, F. [1 ]
Yaroshenko, A. [1 ]
Kunka, D. [2 ,3 ]
Besser, H. [4 ]
Pfeiffer, F. [1 ,5 ]
Mohr, J. [2 ,3 ]
机构
[1] Tech Univ Munich, Dept Phys, Lehrstuhl Biomed Phys, D-85748 Garching, Germany
[2] Tech Univ Munich, Inst Med Tech, D-85748 Garching, Germany
[3] Karlsruhe Inst Technol, Inst Microstruct Technol, Hermann von Helmholtz Pl 1, D-76344 Eggenstein Leopoldshafen, Germany
[4] Karlsruhe Inst Technol, Inst Appl Mat, Hermann von Helmholtz Pl 1, D-76344 Eggenstein Leopoldshafen, Germany
[5] Tech Univ Munich, Inst Diagnost & Intervent Radiol, Klinikum Rechts Isar, D-81675 Munich, Germany
关键词
radiography; medical imaging; microstructures; x-ray gratings; height measurement; phase-contrast; PHASE TOMOGRAPHY; VISUALIZATION; FABRICATION; GRATINGS;
D O I
10.1088/0957-0233/27/2/025015
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We report on a method to characterize the height of periodic x-ray absorbing structures. Such structures are used for example in grating-based x-ray interferometry. In contrast to other techniques, our approach allows for a non-destructive determination of the height based on a few transmission measurements. It can be used with conventional laboratory-based x-ray setups and is therefore of great interest at the application sites of the structures, as it allows further characterization without the need of additional hardware. Here we present the principle of the method, show first results acquired with an absorption grating and compare them with theoretical calculations and those obtained using a destructive method.
引用
收藏
页数:6
相关论文
共 17 条
[1]  
Becker E. W., 1986, Microelectronic Engineering, V4, P35, DOI 10.1016/0167-9317(86)90004-3
[2]   Fabrication of diffraction gratings for hard X-ray phase contrast imaging [J].
David, C. ;
Bruder, J. ;
Rohbeck, T. ;
Gruenzweig, C. ;
Kottler, C. ;
Diaz, A. ;
Bunk, O. ;
Pfeiffer, F. .
MICROELECTRONIC ENGINEERING, 2007, 84 (5-8) :1172-1177
[3]   Toward Clinical X-ray Phase-Contrast CT Demonstration of Enhanced Soft-Tissue Contrast in Human Specimen [J].
Donath, Tilman ;
Pfeiffer, Franz ;
Bunk, Oliver ;
Gruenzweig, Christian ;
Hempel, Eckhard ;
Popescu, Stefan ;
Vock, Peter ;
David, Christian .
INVESTIGATIVE RADIOLOGY, 2010, 45 (07) :445-452
[4]   Fabrication and Characterization of Analyzer Gratings with High Aspect Ratios for Phase Contrast Imaging Using a Talbot Interferometer [J].
Kenntner, Johannes ;
Altapova, Venera ;
Grund, Thomas ;
Pantenburg, Franz Josef ;
Meiser, Jan ;
Baumbach, Tilo ;
Mohr, Juergen .
X-RAY OPTICS AND MICROANALYSIS, 2012, 1437 :89-93
[5]   Phase-sensitive imaging and phase tomography using X-ray interferometers [J].
Momose, A .
OPTICS EXPRESS, 2003, 11 (19) :2303-2314
[6]   Four-dimensional X-ray phase tomography with Talbot interferometry and white synchrotron radiation: dynamic observation of a living worm [J].
Momose, Atsushi ;
Yashiro, Wataru ;
Harasse, Sebastien ;
Kuwabara, Hiroaki .
OPTICS EXPRESS, 2011, 19 (09) :8423-8432
[7]   High-resolution visualization of airspace structures in intact mice via synchrotron phase-contrast X-ray imaging (PCXI) [J].
Parsons, David W. ;
Morgan, Kaye ;
Donnelley, Martin ;
Fouras, Andreas ;
Crosbie, Jeffrey ;
Williams, Ivan ;
Boucher, Richard C. ;
Uesugi, Kentaro ;
Yagi, Naoto ;
Siu, Karen K. W. .
JOURNAL OF ANATOMY, 2008, 213 (02) :217-227
[8]   High-resolution brain tumor visualization using three-dimensional x-ray phase contrast tomography [J].
Pfeiffer, F. ;
Bunk, O. ;
David, C. ;
Bech, M. ;
Le Duc, G. ;
Bravin, A. ;
Cloetens, P. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (23) :6923-6930
[9]   Hard-X-ray dark-field imaging using a grating interferometer [J].
Pfeiffer, F. ;
Bech, M. ;
Bunk, O. ;
Kraft, P. ;
Eikenberry, E. F. ;
Broennimann, Ch. ;
Gruenzweig, C. ;
David, C. .
NATURE MATERIALS, 2008, 7 (02) :134-137
[10]   Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources [J].
Pfeiffer, F ;
Weitkamp, T ;
Bunk, O ;
David, C .
NATURE PHYSICS, 2006, 2 (04) :258-261