Basalt-polypropylene fiber reinforced concrete for durable and sustainable pipe production. Part 1: Experimental program

被引:21
作者
Deng, Zhiyun [1 ,2 ]
Liu, Xinrong [1 ,2 ]
Chen, Peng [1 ,2 ]
de la Fuente, Albert [3 ]
Zhou, Xiaohan [1 ,2 ]
Liang, Ninghui [1 ,2 ]
Han, Yafeng [1 ,2 ]
Du, Libing [1 ,2 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[2] Natl Joint Engn Res Ctr Geohazards Prevent Reserv, Chongqing, Peoples R China
[3] UPC BarcelonaTECH, Civil & Environm Engn, Jordi Girona 1-3, Barcelona 08034, Spain
关键词
basalt‐ polypropylene fiber reinforced concrete; fiber reinforced concrete pipe; mechanical response; post‐ cracking strength; three‐ edge bearing test; MECHANICAL-PROPERTIES; FLEXURAL TOUGHNESS; IMPACT RESPONSE; STEEL; PERFORMANCE; BEHAVIOR; DESIGN;
D O I
10.1002/suco.202000759
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental program consisting in producing and testing reinforced concrete pipes (RCPs) under the three-edge bearing tests considering different types of reinforcement was carried out. Four types of RCPs were produced, these reinforced with: (1) polypropylene macrofibers; (2) basalt microfibers; (3) combination of both (hybrid reinforcement); and (4) plain concrete. The analysis of the crack patterns and both service and ultimate mechanical responses allowed concluding that the use of fibers do not lead to an effective increase of the first cracking load; however, both types of fibers allowed a better crack width control respect to the standard RCP. In this regard, basalt microfiber reinforced concrete led to a better response caused by concentrated loads (jacketing) whilst polypropylene macrofibers increased the concrete pipe performance in terms of bearing capacity and flexural crack control. The hybrid fiber reinforced concrete was found to be the most suitable alternative for increasing the load bearing capacity and the crack width control for service loads. These incipient experimental results permit to conclude that this type of hybrid basalt-polypropylene fiber reinforced concretes are an interesting alternative to traditional steel-cage RCPs.
引用
收藏
页码:311 / 327
页数:17
相关论文
共 54 条
[1]   Performance of Steel Fiber-Reinforced Concrete Pipes [J].
Abolmaali, A. ;
Mikhaylova, A. ;
Wilson, A. ;
Lundy, J. .
TRANSPORTATION RESEARCH RECORD, 2012, (2313) :168-177
[2]  
Al Rikabi FT, 2019, PIPELINES 2019: MULTIDISCIPLINARY TOPICS, UTILITY ENGINEERING, AND SURVEYING, P547
[3]   Experimental Investigation of Thin-Wall Synthetic Fiber-Reinforced Concrete Pipes [J].
Al Rikabi, Fouad T. ;
Sargand, Shad M. ;
Kurdziel, John ;
Hussein, Husam H. .
ACI STRUCTURAL JOURNAL, 2018, 115 (06) :1671-1681
[4]   Evaluation of Synthetic Fiber Reinforced Concrete Pipe Performance Using Three-Edge Bearing Test [J].
Al Rikabi, Fouad T. ;
Sargand, Shad M. ;
Kurdziel, John .
JOURNAL OF TESTING AND EVALUATION, 2019, 47 (02) :942-958
[5]  
[Anonymous], 2003, 41392003 AS
[6]  
[Anonymous], 2002, 19162002 EN
[7]  
ASTM C76-19a, 2019, STANDARD SPECIFICATI
[8]  
BANTHIA N, 1995, ACI MATER J, V92, P48
[9]   Properties of glass concrete reinforced with short basalt fibre [J].
Borhan, Tumadhir Merawi .
MATERIALS & DESIGN, 2012, 42 :265-271
[10]   Mechanical behaviour of basalt fibre reinforced concrete [J].
Branston, John ;
Das, Sreekanta ;
Kenno, Sara Y. ;
Taylor, Craig .
CONSTRUCTION AND BUILDING MATERIALS, 2016, 124 :878-886