Role of screw proximity in the fixation of transverse patellar fractures with screws and a wire

被引:18
作者
Chang, Chih-Wei [1 ,2 ,3 ]
Chen, Yen-Nien [1 ,4 ]
Li, Chun-Ting [5 ]
Chung, Yu-Hsuan [4 ]
Chang, Chih-Han [1 ]
Peng, Yao-Te [1 ,6 ]
机构
[1] Natl Cheng Kung Univ, Dept BioMed Engn, Tainan, Taiwan
[2] Natl Cheng Kung Univ, Coll Med, Dept Orthoped, Tainan, Taiwan
[3] Natl Cheng Kung Univ, Natl Cheng Kung Univ Hosp, Coll Med, Dept Orthoped, Tainan, Taiwan
[4] Show Chwan Mem Hosp, Dept Orthoped, Changhua, Taiwan
[5] Natl Univ Tainan, Grad Inst Mechatron Syst Engn, Tainan, Taiwan
[6] Met Ind Res & Dev Ctr, Kaohsiung, Taiwan
来源
JOURNAL OF ORTHOPAEDIC SURGERY | 2018年 / 26卷 / 03期
关键词
cannulated screw; finite element method; screw proximity; transverse patellar fracture; wire; STAINLESS-STEEL WIRE; TENSION-BAND; CANNULATED SCREWS; INTERNAL-FIXATION; OPEN REDUCTION; COMPLICATIONS; PLATE; NAIL;
D O I
10.1177/2309499018789705
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Clinical and biomechanical studies have reported that using supportive screws and a wire instead of the common Kirschner wires for modified tension band wiring improves the stability of fractured patellae. However, the effect of screw proximity on the fixation of a fractured patella remains unclear. Therefore a numerical study was conducted to examine the effects of screw proximity on biomechanical responses in a simulated patellar fracture fixed using two parallel cannulated screws and anterior tension band wiring. Methods: A patellar model with a transverse fracture and loads simulating patellar tendon forces applied on the patella were used in the present simulation. The surgical fixation consisted of two 4.0-mm parallel partially threaded cannulated screws with a figure-of-eight tension band made using a 1.25-mm stainless steel wire. Biomechanical responses at two screw proximities, 5 and 10 mm from the leading edge of the patella, were investigated. Results: Superficial screw placement (5 mm) yielded higher stability, lower wire loads, and lower bone contact pressures than the deep placement (10 mm). The deep placement of screws exerted a higher load on the wire but a lower force on the screw than superficial placement did. Conclusion: This is the first numerical study to examine the effects of screw location on the fixation of a fractured patella using cannulated screws and tension band wiring. Considering the favorable biomechanical responses, superficial placement (5 mm below the leading edge of the patella) is recommended for screw insertion when treating a transverse fractured patella.
引用
收藏
页数:9
相关论文
共 32 条
  • [1] Open reduction internal fixation of displaced transverse patella fractures with figure-eight wiring through parallel cannulated compression screws
    Berg, EE
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (08) : 573 - 576
  • [2] FRACTURES OF THE PATELLA TREATED BY OPERATION
    BOSTMAN, O
    KIVILUOTO, O
    SANTAVIRTA, S
    NIRHAMO, J
    WILPPULA, E
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1983, 102 (02) : 78 - 81
  • [3] BOSTROM A, 1972, ACTA ORTHOP SCAND, P1
  • [4] Comparison of cannulated screws with FiberWire or stainless steel wire for patella fracture fixation: A pilot study
    Bryant, Tony L.
    Anderson, Christopher L.
    Stevens, Christopher G.
    Conrad, Bryan P.
    Vincent, Heather K.
    Sadasivan, Kalia K.
    [J]. JOURNAL OF ORTHOPAEDICS, 2015, 12 (02) : 92 - 96
  • [5] The mechanical and material properties of elderly human articular cartilage subject to impact and slow loading
    Burgin, L. V.
    Edelsten, L.
    Aspden, R. M.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2014, 36 (02) : 226 - 232
  • [6] Open Reduction and Internal Fixation of Displaced Patella Inferior Pole Fractures With Anterior Tension Band Wiring Through Cannulated Screws
    Chang, Shi-Min
    Ji, Xiang-Ling
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (06) : 366 - 370
  • [7] Numerical investigation of fracture impaction in proximal humeral fracture fixation with locking plate and intramedullary nail
    Chen, Yen-Nien
    Chang, Chih-Wei
    Lin, Chia-Wei
    Wang, Chih-Wei
    Peng, Yao-Te
    Chang, Chih-Han
    Li, Chun-Ting
    [J]. INTERNATIONAL ORTHOPAEDICS, 2017, 41 (07) : 1471 - 1480
  • [8] Biomechanical investigation of titanium elastic nail prebending for treating diaphyseal long bone fractures
    Chen, Yen-Nien
    Lee, Pei-Yuan
    Chang, Chih-Wei
    Ho, Yi-Hung
    Peng, Yao-Te
    Chang, Chih-Han
    Li, Chun-Ting
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) : 115 - 126
  • [9] Computational comparison of tibial diaphyseal fractures fixed with various degrees of prebending of titanium elastic nails and with and without end caps
    Chen, Yen-Nien
    Lee, Pei-Yuan
    Chang, Chih-Han
    Chang, Chih-Wei
    Ho, Yi-Hung
    Li, Chun-Ting
    Peng, Yao-Te
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (10): : 2339 - 2346
  • [10] Finite Element Analysis of Plantar Fascia During Walking: A Quasi-static Simulation
    Chen, Yen-Nien
    Chang, Chih-Wei
    Li, Chun-Ting
    Chang, Chih-Han
    Lin, Cheng-Feng
    [J]. FOOT & ANKLE INTERNATIONAL, 2015, 36 (01) : 90 - 97