Detection of phenol in aqueous solution using an AT-cut quartz thickness shear mode sensor

被引:6
作者
Reddy, SM [1 ]
机构
[1] Univ Surrey, Sch Biol Sci, Guildford GU2 5XH, Surrey, England
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2000年 / 12卷 / 1-2期
关键词
quartz; shear; phenol; environmental sensor;
D O I
10.1016/S0928-4931(00)00152-1
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The AT-cut quartz crystal, operating in the thickness shear mode, has been used to detect 4-aminophenol. The mechanism of response involves a specific reaction with o-cresol to produce a hydrophobic indophenol dye that precipitates out and adsorbs to the quartz surface, Adsorption specificity for the crystal surface is enhanced via the pretreatment of the surface with a hydrophobic poly(vinyl chloride) (PVC) layer, It is shown that there is a critical PVC loading that affords optimised speed of response and amplitude. At a high loading of 0.05% (w/v) of PVC (in tetrahydrofuran), the resulting desolvated polymer layer exhibits a defined porous structure, The pores act as nucleation sites for the oligomeric precipitating species. At lower PVC loadings, the membrane is non-uniform and inhomogeneous. However, the speed and amplitude of response to indophenol at such loadings are enhanced compared with that of a bare crystal or crystal with high PVC loadings, (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:23 / 28
页数:6
相关论文
共 16 条
[1]   Determination of organophosphorus and carbamate pesticides using a piezoelectric biosensor [J].
Abad, JM ;
Pariente, F ;
Hernández, L ;
Abruña, HD ;
Lorenzo, E .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2848-2855
[2]   Response of quartz-crystal resonators to gas and liquid analyte exposure [J].
Behling, C ;
Lucklum, R ;
Hauptmann, P .
SENSORS AND ACTUATORS A-PHYSICAL, 1998, 68 (1-3) :388-398
[3]   Possibilities and limitations in quantitative determination of polymer shear parameters by TSM resonators [J].
Behling, C ;
Lucklum, R ;
Hauptmann, P .
SENSORS AND ACTUATORS A-PHYSICAL, 1997, 61 (1-3) :260-266
[4]  
BISHOP E, 1972, INDICATORS, P133
[5]   Piezoelectric quartz crystal biosensors [J].
Bunde, RL ;
Jarvi, EJ ;
Rosentreter, JJ .
TALANTA, 1998, 46 (06) :1223-1236
[6]   DNA binding and hybridization on gold and derivatized surfaces [J].
Caruso, F ;
Rodda, E ;
Furlong, DN ;
Haring, V .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 41 (1-3) :189-197
[7]  
Korenman YI, 1997, J ANAL CHEM+, V52, P278
[8]  
Kuchmenko TA, 1999, J ANAL CHEM+, V54, P161
[9]  
MOLLER KM, 1966, CR TRAV LAB CARLSB, V35, P369
[10]   Surfactant-modified poly(vinyl chloride) membranes as biocompatible interfaces for amperometric enzyme electrodes [J].
Reddy, SM ;
Vadgama, PM .
ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) :77-89