Reliability of HR-pQCT Derived Cortical Bone Structural Parameters When Using Uncorrected Instead of Corrected Automatically Generated Endocortical Contours in a Cross-Sectional Study: The Maastricht Study

被引:11
作者
de Waard, Ellis A. C. [1 ,2 ]
Sarodnik, Cindy [1 ,2 ]
Pennings, Alexander [1 ]
de Jong, Joost J. A. [1 ,2 ]
Savelberg, Hans H. C. M. [2 ,3 ]
van Geel, Tineke A. [2 ,4 ,5 ]
van der Kallen, Carla J. [6 ,7 ]
Stehouwer, Coen D. A. [6 ,7 ]
Schram, Miranda T. [6 ,7 ,8 ]
Schaper, Nicolaas [4 ,6 ,7 ]
Dagnelie, Pieter C. [6 ,7 ]
Geusens, Piet P. M. M. [4 ,9 ,10 ]
Koster, Annemarie [4 ,11 ]
van Rietbergen, Bert [12 ]
van den Bergh, Joop P. W. [2 ,9 ,10 ,13 ]
机构
[1] Maastricht Univ, Dept Internal Med, Subdiv Rheumatol, POB 616, NL-6200 MD Maastricht, Netherlands
[2] Maastricht Univ, NUTRIM Sch Nutr & Translat Res Metab, Maastricht, Netherlands
[3] Maastricht Univ, Dept Human Movement Sci, Maastricht, Netherlands
[4] Maastricht Univ, CAPHRI, Maastricht, Netherlands
[5] Maastricht Univ, Dept Family Med, Maastricht, Netherlands
[6] Maastricht Univ, Dept Internal Med, Med Ctr, Maastricht, Netherlands
[7] Maastricht Univ, CARIM Sch Cardiovasc Dis, Maastricht, Netherlands
[8] Maastricht Univ, Heart & Vasc Ctr, Med Ctr, Maastricht, Netherlands
[9] Maastricht Univ, Dept Internal Med, Subdiv Rheumatol, Med Ctr, Maastricht, Netherlands
[10] Univ Hasselt, Biomed Res Inst, Hasselt, Belgium
[11] Maastricht Univ, Dept Social Med, Maastricht, Netherlands
[12] Eindhoven Univ Technol, Fac Biomed Engn, Eindhoven, Netherlands
[13] VieCuri Med Ctr, Dept Internal Med, Subdiv Endocrinol, Venlo, Netherlands
关键词
High resolution peripheral quantitative computed tomography; Bone microarchitecture; Cortical bone analysis; Endocortical contour; DISTAL RADIUS; TRABECULAR COMPARTMENTS; POSTMENOPAUSAL WOMEN; COMPUTED-TOMOGRAPHY; PRECISION; POROSITY; MICROARCHITECTURE; QUALITY; TIBIA; REPRODUCIBILITY;
D O I
10.1007/s00223-018-0416-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Most HR-pQCT studies examining cortical bone use an automatically generated endocortical contour (AUTO), which is manually corrected if it visually deviates from the apparent endocortical margin (semi-automatic method, S-AUTO). This technique may be prone to operator-related variability and is time consuming. We examined whether the AUTO instead of the S-AUTO method can be used for cortical bone analysis. Fifty scans of the distal radius and tibia from participants of The Maastricht Study were evaluated with AUTO, and subsequently with S-AUTO by three independent operators. AUTO cortical bone parameters were compared to the average parameters obtained by the three operators (S-AUTOmean). All differences in mean cortical bone parameters between AUTO and S-AUTOmean were < 5%, except for lower AUTO cortical porosity of the radius (- 16%) and tibia (- 6%), and cortical pore volume (Ct.Po.V) of the radius (- 7%). The ICC of S-AUTOmean and AUTO was > 0.90 for all parameters, except for cortical pore diameter of the radius (0.79) and tibia (0.74) and Ct.Po.V of the tibia (0.89), without systematic errors on the Bland-Altman plots. The precision errors (RMS-CV%) of the radius parameters between S-AUTOmean and AUTO were comparable to those between the individual operators, whereas the tibia RMS-CV% between S-AUTOmean and AUTO were higher than those of the individual operators. Comparison of the three operators revealed clear inter-operator variability. This study suggests that the AUTO method can be used for cortical bone analysis in a cross-sectional study, but that the absolute values-particularly of the porosity-related parameters-will be lower.
引用
收藏
页码:252 / 265
页数:14
相关论文
共 26 条
  • [1] The role of cortical bone and its microstructure in bone strength
    Augat, Peter
    Schorlemmer, Sandra
    [J]. AGE AND AGEING, 2006, 35 : 27 - 31
  • [2] Role of cortical bone in bone fragility
    Bala, Yohann
    Zebaze, Roger
    Seeman, Ego
    [J]. CURRENT OPINION IN RHEUMATOLOGY, 2015, 27 (04) : 406 - 413
  • [3] The comparability of HR-pQCT bone measurements is improved by scanning anatomically standardized regions
    Bonaretti, S.
    Majumdar, S.
    Lang, T. F.
    Khosla, S.
    Burghardt, A. J.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2017, 28 (07) : 2115 - 2128
  • [4] Operator variability in scan positioning is a major component of HR-pQCT precision error and is reduced by standardized training
    Bonaretti, S.
    Vilayphiou, N.
    Chan, C. M.
    Yu, A.
    Nishiyama, K.
    Liu, D.
    Boutroy, S.
    Ghasem-Zadeh, A.
    Boyd, S. K.
    Chapurlat, R.
    McKay, H.
    Shane, E.
    Bouxsein, M. L.
    Black, D. M.
    Majumdar, S.
    Orwoll, E. S.
    Lang, T. F.
    Khosla, S.
    Burghardt, A. J.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2017, 28 (01) : 245 - 257
  • [5] In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography
    Boutroy, S
    Bouxsein, ML
    Munoz, F
    Delmas, PD
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2005, 90 (12) : 6508 - 6515
  • [6] Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysis
    Buie, Helen R.
    Campbell, Graeme M.
    Klinck, R. Joshua
    MacNeil, Joshua A.
    Boyd, Steven K.
    [J]. BONE, 2007, 41 (04) : 505 - 515
  • [7] Multicenter precision of cortical and trabecular bone quality measures assessed by high-resolution peripheral quantitative computed tomography
    Burghardt, Andrew J.
    Pialat, Jean-Baptiste
    Kazakia, Galateia J.
    Boutroy, Stephanie
    Engelke, Klaus
    Patsch, Janina M.
    Valentinitsch, Alexander
    Liu, Danmei
    Szabo, Eva
    Bogado, Cesar E.
    Belen Zanchetta, Maria
    McKay, Heather A.
    Shane, Elizabeth
    Boyd, Steven K.
    Bouxsein, Mary L.
    Chapurlat, Roland
    Khosla, Sundeep
    Majumdar, Sharmila
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2013, 28 (03) : 524 - 536
  • [8] Reproducibility of direct quantitative measures of cortical bone microarchitecture of the distal radius and tibia by HR-pQCT
    Burghardt, Andrew J.
    Buie, Helen R.
    Laib, Andres
    Majumdar, Sharmila
    Boyd, Steven K.
    [J]. BONE, 2010, 47 (03) : 519 - 528
  • [9] ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES
    GLUER, CC
    BLAKE, G
    LU, Y
    BLUNT, BA
    JERGAS, M
    GENANT, HK
    [J]. OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) : 262 - 270
  • [10] A new method for the model-independent assessment of thickness in three-dimensional images
    Hildebrand, T
    Ruegsegger, P
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1997, 185 : 67 - 75