Mid-infrared laser spectroscopic determination of isotope ratios of N2O at trace levels using wavelength modulation and balanced path length detection

被引:27
|
作者
Waechter, H. [1 ]
Sigrist, M. W. [1 ]
机构
[1] ETH, Inst Quantum Elect, Laser Spect & Sensing Lab, CH-8093 Zurich, Switzerland
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2007年 / 87卷 / 03期
关键词
D O I
10.1007/s00340-007-2576-z
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a new mid-infrared laser spectrometer for high-precision measurements of isotopic ratios of molecules at ppm concentrations. Results are discussed for nitrous oxide (N2O), where a precision of 3 parts per thousand for a single measurement and a reproducibility of 6 parts per thousand have been achieved for a concentration of 825 ppm. The room-temperature laser source employed is based on difference-frequency generation delivering a continuous-wave power up to 23 mu W at wavelengths between 4.3 mu m and 4.7 mu m and a line width of 1 MHz. Two different measurement methods are compared; wavelength modulation with first-harmonic detection and direct absorption spectroscopy by recording the spectrum with a data-acquisition card. Two different detection schemes were employed; either all isotopomers were measured using the long path (36 m) of the multipass cell or a balanced path length detection scheme was used, where the main isotope was measured with a beam along a shorter path (40 cm) in the multipass cell. A single-pass reference cell was designed, offering two different path lengths for balanced path length detection. All combinations of measurement methods and detection schemes were tested regarding precision of a single measurement and long-term stability. The advantages and disadvantages of various measurement approaches are discussed.
引用
收藏
页码:539 / 546
页数:8
相关论文
共 21 条
  • [11] Quantitative HCN measurements in CH4/N2O/O2/N2 flames using mid-infrared polarization spectroscopy
    Sun, Z. W.
    Li, Z. S.
    Konnov, A. A.
    Alden, M.
    COMBUSTION AND FLAME, 2011, 158 (10) : 1898 - 1904
  • [12] Mid-infrared laser absorption spectrometers based upon all-diode laser difference frequency generation and a room temperature quantum cascade laser for the detection of CO, N2O and NO
    Kasyutich, V. L.
    Holdsworth, R. J.
    Martin, P. A.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 92 (02): : 271 - 279
  • [13] Mid-infrared laser absorption spectrometers based upon all-diode laser difference frequency generation and a room temperature quantum cascade laser for the detection of CO, N2O and NO
    V.L. Kasyutich
    R.J. Holdsworth
    P.A. Martin
    Applied Physics B, 2008, 92 : 271 - 279
  • [14] Re-injection off-axis integrated cavity output spectroscopy for the simultaneous detection of N2O, H2O and CO with a mid-infrared QCL laser
    Yang, Xi
    Zhang, Zhirong
    Xia, Hua
    Sun, Pengshuai
    Pang, Tao
    Wu, Bian
    Liu, Xu
    Guo, Qiang
    ANALYST, 2024, 149 (03) : 909 - 916
  • [15] Real-time monitoring of CH4 and N2O emissions from livestock using mid-infrared external cavity quantum cascade laser absorption spectroscopy
    Shen, Fengjiao
    Chen, Dong
    Wang, Gaoxuan
    Lu, Jun
    Hu, Xueyou
    Gao, Xiaoming
    Fertein, Eric
    Chen, Weidong
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2024, 327
  • [16] Mid-infrared laser absorption sensor for simultaneous trace detection of CH3CN, H2O, and CH4 in the ambient air
    Guan, Hongfei
    Wang, Xiaoyu
    Liu, Xu
    Yuan, Liming
    Li, Jinyi
    Du, Zhenhui
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 349
  • [17] A MEMS modulator-based dual-channel mid-infrared laser heterodyne radiometer for simultaneous remote sensing of atmospheric CH4, H2O and N2O
    Xue, Zhengyue
    Shen, Fengjiao
    Li, Jun
    Liu, Xiaohai
    Wang, Jingjing
    Wang, Guishi
    Liu, Kun
    Chen, Weidong
    Gao, Xiaoming
    Tan, Tu
    OPTICS EXPRESS, 2022, 30 (18) : 31828 - 31839
  • [18] Visualizing hidden electron trap levels in Gd3Al2Ga3O12:Ce crystals using a mid-infrared free-electron laser
    Kitaura, Mamoru
    Zen, Heishun
    Kamada, Kei
    Kurosawa, Shunsuke
    Watanabe, Shinta
    Ohnishi, Akimasa
    Hara, Kazuhiko
    APPLIED PHYSICS LETTERS, 2018, 112 (03)
  • [19] Active standoff detection of CH4 and N2O leaks using hard-target backscattered light using an open-path quantum cascade laser sensor
    Diaz, Adrian
    Thomas, Benjamin
    Castillo, Paulo
    Gross, Barry
    Moshary, Fred
    APPLIED PHYSICS B-LASERS AND OPTICS, 2016, 122 (05):
  • [20] Active standoff detection of CH4 and N2O leaks using hard-target backscattered light using an open-path quantum cascade laser sensor
    Adrian Diaz
    Benjamin Thomas
    Paulo Castillo
    Barry Gross
    Fred Moshary
    Applied Physics B, 2016, 122