Detection of low levels of Listeria monocytogenes cells by using a fiber-optic immunosensor

被引:85
|
作者
Geng, T
Morgan, MT
Bhunia, AK
机构
[1] Purdue Univ, Dept Food Sci, Mol Food Microbiol Lab, W Lafayette, IN 47906 USA
[2] Purdue Univ, Dept Food Sci, Sensors & Controls Lab, W Lafayette, IN 47906 USA
关键词
D O I
10.1128/AEM.70.10.6138-6146.2004
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Biosensor technology has a great potential to meet the need for sensitive and nearly real-time microbial detection from foods. An antibody-based fiber-optic biosensor to detect low levels of Listeria monocytogenes cells following an enrichment step was developed. The principle of the sensor is a sandwich immunoassay where a rabbit polyclonal antibody was first immobilized on polystyrene fiber waveguides through a biotin-streptavidin reaction to capture Listeria cells on the fiber. Capture of cells on the fibers was confirmed by scanning electron microscopy. A cyanine 5-labeled murine monoclonal antibody, C11E9, was used to generate a specific fluorescent signal, which was acquired by launching a 635-nm laser light from an Analyte 2000 and collected by a photodetector at 670 to 710 nm. This immunosensor was specific for L. monocytogenes and showed a significantly higher signal strength than for other Listeria species or other microorganisms, including Escherichia coli, Enterococcus faecalis, Salmonella enterica, Lactobacillus plantarum, Carnobacterium gallinarum, Hafnia alvei, Corynebacterium glutamicum, Enterobacter aerogenes, Pseudomonas aeruginosa, and Serratia marcescens, in pure or in mixed-culture setup. Fiber-optic results could be obtained within 2.5 h of sampling. The sensitivity threshold was about 4.3x10(3) CFU/ml for a pure culture of L. monocytogenes grown at 37degreesC. When L. monocytogenes was mixed with lactic acid bacteria or grown at 10degreesC with 3.5% NaCl, the detection threshold was 4.1x10(4) or 2.8x10(7) CFU/ml, respectively. In less than 24 h, this method could detect L. monocytogenes in hot dog or bologna naturally contaminated or artificially inoculated with 10 to 1,000 CFU/g after enrichment in buffered Listeria enrichment broth.
引用
收藏
页码:6138 / 6146
页数:9
相关论文
共 50 条
  • [1] Detection of Listeria monocytogenes using an automated fiber-optic biosensor:: RAPTOR
    Kim, Giyoung
    Morgan, Mark T.
    Ess, Daniel
    Hahm, Byoung-Kwon
    Kothapalli, Aparna
    Valadez, Angela
    Bhunia, Arun
    ADVANCED NONDESTRUCTIVE EVALUATION I, PTS 1 AND 2, PROCEEDINGS, 2006, 321-323 : 1168 - 1171
  • [2] Highly specific fiber optic immunosensor coupled with immunomagnetic separation for detection of low levels of Listeria monocytogenes and L. ivanovii
    Marcelo Mendonça
    Neida L Conrad
    Fabricio R Conceição
    Ângela N Moreira
    Wladimir P da Silva
    José AG Aleixo
    Arun K Bhunia
    BMC Microbiology, 12
  • [3] Highly specific fiber optic immunosensor coupled with immunomagnetic separation for detection of low levels of Listeria monocytogenes and L. ivanovii
    Mendonca, Marcelo
    Conrad, Neida L.
    Conceicao, Fabricio R.
    Moreira, Angela N.
    da Silva, Wladimir P.
    Aleixo, Jose A. G.
    Bhunia, Arun K.
    BMC MICROBIOLOGY, 2012, 12
  • [4] An automated fiber-optic biosensor based binding inhibition assay for the detection of Listeria monocytogenes
    Kim, Giyoung
    Morgan, Mark
    Ess, Daniel
    Hahm, Byoung-Kwon
    Kothapalli, Aparna
    Bhunia, Arun
    FOOD SCIENCE AND BIOTECHNOLOGY, 2007, 16 (03) : 337 - 342
  • [5] Portable fiber-optic immunosensor for detection of methsulfuron methyl
    Xing, WL
    Ma, LR
    Jiang, ZH
    Cao, FH
    Jia, MH
    TALANTA, 2000, 52 (05) : 879 - 883
  • [6] Fiber-optic immunosensor for mycotoxins
    Maragos, CM
    Thompson, VS
    NATURAL TOXINS, 1999, 7 (06) : 371 - 376
  • [7] Fiber-optic immunosensor for the detection of fumonisin B-1
    Thompson, VS
    Maragos, CM
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1996, 44 (04) : 1041 - 1046
  • [8] Fiber-optic immunosensor for measurement of myoglobin
    Hanbury, CM
    Miller, WG
    Harris, RB
    CLINICAL CHEMISTRY, 1997, 43 (11) : 2128 - 2136
  • [9] Measurement of mycotoxins in food with a fiber-optic immunosensor
    Maragos, CM
    JOURNAL OF CLINICAL LIGAND ASSAY, 1997, 20 (01): : 136 - 140
  • [10] Optical Immunosensor for the Detection of Listeria monocytogenes in Food Matrixes
    Servarayan, Karthika Lakshmi
    Krishnamoorthy, Govindan
    Sundaram, Ellairaja
    Karuppusamy, Masiyappan
    Murugan, Marudhamuthu
    Piraman, Shakkthivel
    Vasantha, Vairathevar Sivasamy
    ACS OMEGA, 2023, 8 (18): : 15979 - 15989