Is MIP-OES a suitable alternative to ICP-OES for trace element analysis?

被引:24
作者
Fontoura, Beatriz M. [1 ]
Cora Jofre, Florencia [2 ,3 ]
Williams, Trey [4 ]
Savio, Marianela [2 ,3 ]
Donati, George L. [5 ]
Nobrega, Joaquim A. [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Chem, Grp Appl Instrumental Anal, POB 676, BR-13565905 Sao Carlos, SP, Brazil
[2] Univ Nacl La Pampa, Fac Ciencias Exactas & Nat, Santa Rosa, La Pampa, Argentina
[3] Consejo Nacl Invest Cient & Tecn, Inst Ciencias Tierra & Ambientales La Pampa INCIT, Santa Rosa, La Pampa, Argentina
[4] Clemson Univ, Dept Chem, Clemson, SC 29634 USA
[5] Wake Forest Univ, Dept Chem, Salem Hall,Box 7486, Winston Salem, NC 27109 USA
关键词
MICROWAVE-INDUCED PLASMA; INDUCTIVELY-COUPLED PLASMA; OPTICAL-EMISSION SPECTROMETRY; STANDARD DILUTION ANALYSIS; SOLID-PHASE EXTRACTION; SAMPLE INTRODUCTION SYSTEM; INDUCED NITROGEN PLASMA; ATOMIC-EMISSION; HYDRIDE GENERATION; ATMOSPHERIC-PRESSURE;
D O I
10.1039/d1ja00375e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microwave-induced plasma optical emission spectrometry (MIP-OES) has been attracting growing interest since the introduction of a commercial instrument based on a Hammer cavity and resonant iris system (4100 MP-AES, Agilent Technologies) in 2012. During the past few years, important modifications have been made to the instrument to improve its analytical performance, and new models have been launched (4200 and 4210 MP-AES). These improvements, along with other performance studies, allowed for the instrument's use in several applications, with adequate analytical results, which raises the question of whether MIP-OES has positioned itself to become an alternative to the traditional inductively coupled plasma optical emission spectrometry (ICP-OES). In the present review, we describe recent advances in MIP-OES instrumentation and compare the method's figures of merit, as well as its ability to deal with matrix effects, with those typically observed in ICP-OES. We also discuss recent studies and strategies developed to overcome general MIP-OES limitations. Instrument accessories, plasma diagnostics strategies, new calibration methods, and developments in sample preparation and sample introduction are some of the strategies used to improve MIP-OES sensitivity and accuracy. Therefore, the aims of the present work are to identify applications for which MIP-OES has become competitive with ICP-OES, as well as to describe recent developments that contributed to MIP-OES' acceptance as a cost-effective alternative for trace element analysis.
引用
收藏
页码:966 / 984
页数:19
相关论文
共 95 条
[1]   Dispersive solid phase extraction of gold with magnetite-graphene oxide prior to its determination via microwave plasma-atomic emission spectrometry [J].
Ahmad, Hilal ;
Jalil, Aishah Abdul ;
Triwahyono, Sugeng .
RSC ADVANCES, 2016, 6 (91) :88110-88116
[2]   Microwave-Induced Plasma Optical Emission Spectrometry (MIP OES) and Standard Dilution Analysis to Determine Trace Elements in Pharmaceutical Samples [J].
Althoff, Amanda G. ;
Williams, Charles B. ;
McSweeney, Tina ;
Goncalves, Daniel A. ;
Donati, George L. .
APPLIED SPECTROSCOPY, 2017, 71 (12) :2692-2698
[3]   A simple dilute-and-shoot procedure for Si determination in diesel and biodiesel by microwave-induced plasma optical emission spectrometry [J].
Amais, Renata S. ;
Donati, George L. ;
Schiavo, Daniela ;
Nobrega, Joaquim A. .
MICROCHEMICAL JOURNAL, 2013, 106 :318-322
[4]  
[Anonymous], MICR PLASM AT EM SPE
[5]  
[Anonymous], AG MP EXP SOFTW
[6]  
[Anonymous], Optima 8x00 Series ICP-OES Flat Plate Plasma System
[7]   Simultaneous determination of hydride (Se) and non-hydride-forming (Ca, Mg, K, P, S and Zn) elements in various beverages (beer, coffee, and milk), with minimum sample preparation, by ICP-AES and use of a dual-mode sample-introduction system [J].
Asfaw, A ;
Wibetoe, G .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (01) :173-179
[8]   On-line pseudo-stationary magnetic solid-phase extraction using magnetic cation exchange microparticles and its application to the determination of strontium [J].
Ayala, Alejandro ;
Takagai, Yoshitaka .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (07) :1251-1255
[9]   Sequential Injection Analysis System Exploiting On-line Solid-phase Extraction for the Determination of Strontium and Nickel by Microwave Plasma Atomic Emission Spectrometry [J].
Ayala, Alejandro ;
Takagai, Yoshitaka .
ANALYTICAL SCIENCES, 2018, 34 (03) :387-390
[10]   Microwave plasma atomic emission spectrometry (MP-AES) and its applications - A critical review [J].
Balaram, V. .
MICROCHEMICAL JOURNAL, 2020, 159