High-performance liquid chromatographic method for the determination of benzodiazepines in plasma or serum using the column-switching technique

被引:44
作者
El Mahjoub, A [1 ]
Staub, C [1 ]
机构
[1] Univ Geneva, Inst Med Legale, CH-1211 Geneva 4, Switzerland
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 742卷 / 02期
关键词
column switching; benzodiazepines;
D O I
10.1016/S0378-4347(00)00185-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A column-switching high-performance liquid chromatographic method for the simultaneous determination of five frequently prescribed benzodiazepines: clonazepam, diazepam, flunitrazepam, midazolam and oxazepam was developed. A 50-mu l plasma sample was directly injected into a BioTrap 500 MS (hydrophobic polymer) column. After a washing step with a mixture of phosphate buffet and acetonitrile, the retained benzodiazepines were back-flushed into a reversed-phase (LiChrospher Select B C-8) column with a mobile phase of acetonitrile-phosphate buffer. The method showed excellent linearity from 50 to 1000 ng/ml for clonazepam, flunitrazepam and midazolam and from 50 to 5000 ng/ml for diazepam and oxazepam. The recoveries were around 98% for all the benzodiazepines studied. The relative standard deviation for between and within-day assay was <20% for low concentrations close to the values of the limit of quantification and <4% for high concentrations. The procedure described is relatively simple and rapid because no off-line manipulation of the sample is required: the total analysis time is approximately 30 min. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:381 / 390
页数:10
相关论文
共 14 条
[1]   ANALYSIS OF BENZODIAZEPINES .2. HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FLUORESCENCE DETECTION AFTER MOLECULAR REARRANGEMENT TO ACRIDANONES [J].
DEGIOVANNI, N ;
CHIAROTTI, M .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 428 (02) :321-329
[2]  
ELMAHJOUB A, INN PRESS J PHARM BI
[3]   DETERMINATION OF DRUGS BY DIRECT-INJECTION OF PLASMA INTO A BIOCOMPATIBLE EXTRACTION COLUMN BASED ON A PROTEIN-ENTRAPPED HYDROPHOBIC PHASE [J].
HERMANSSON, J ;
GRAHN, A .
JOURNAL OF CHROMATOGRAPHY A, 1994, 660 (1-2) :119-129
[4]   COLLECTION OF ANALYTICAL DATA FOR BENZODIAZEPINES AND BENZOPHENONES [J].
JAPP, M ;
GARTHWAITE, K ;
GEESON, AV ;
OSSELTON, MD .
JOURNAL OF CHROMATOGRAPHY, 1988, 439 (02) :317-339
[5]   Solid phase micro extraction coupled with semi-microcolumn high performance liquid chromatography for the analysis of benzodiazepines in human urine [J].
Jinno, K ;
Taniguchi, M ;
Hayashida, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) :1081-1091
[6]  
KUDO K, 1988, J CHROMATOGR, V431, P351
[7]   INFLUENCE OF SOLUTE POLARITY IN COLUMN-SWITCHING CHROMATOGRAPHY FOR THE ASSAY OF DRUGS IN PLASMA AND URINE [J].
LECAILLON, JB ;
FEBVRE, N ;
SOUPPART, C .
JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC) :493-506
[8]   Automated on-line solid-phase extraction gas chromatography with nitrogen-phosphorus detection: Determination of benzodiazepines in human plasma [J].
Louter, AJH ;
Bosma, E ;
Schipperen, JCA ;
Vreuls, JJ ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY B, 1997, 689 (01) :35-43
[9]   IDENTIFICATION AND DIFFERENTIATION OF BENZODIAZEPINES AND THEIR METABOLITES IN URINE BY COMPUTERIZED GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
MAURER, H ;
PFLEGER, K .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 422 :85-101
[10]  
MOORE CM, 1991, CLIN CHEM, V37, P804