Enhanced Control of Three-Phase Grid-Connected Renewables with Fault Ride-Through Capability under Voltage Sags

被引:1
|
作者
Rey-Boue, Alexis B. [1 ]
Guerrero-Rodriguez, N. F. [2 ]
Stoeckl, Johannes [3 ]
Strasser, Thomas I. [3 ]
机构
[1] Univ Politecn Cartagena, Dept Elect Comp Technol & Projects, C Dr Fleming S-N, Cartagena 30202, Spain
[2] Pontificia Univ Catolica Madre & Maestra PUCMM, Engn Sci, Ave Abraham Lincoln Esq Romulo Betancourt, Santo Domingo 2748, Dominican Rep
[3] AIT Austrian Inst Technol, Ctr Energy Elect Energy Syst, Giefinggasse 2, A-1210 Vienna, Austria
关键词
controller hardware-in-the-loop; constant active power control; dual second-order generalized integrator frequency-locked loop; low-voltage ride-through; voltage sag; renewable energy system; POWER-CONTROL; PHOTOVOLTAIC SYSTEMS; CURRENT LIMITATION; LVRT CAPABILITY; CONVERTERS; INVERTERS; STRATEGY; SYNCHRONIZATION; VERIFICATION; SIMULATION;
D O I
10.3390/electronics11091404
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The uninterruptible operation of grid-connected renewables under the occurrence of grid voltage sags is addressed in this work. This is achieved due to the incorporation of an enhanced control algorithm of a renewable source. The low-voltage ride-through algorithm was developed in accordance to the voltage profile introduced by IEC 61400-21 regarding grid voltage sags. To guarantee continuous operation of the renewable agent during voltage sags, not only instantaneous reactive power but also instantaneous active power under moderate voltage sags was injected to the utility grid fulfilling grid code requirements. A dual second-order generalized integrator frequency-locked loop synchronization algorithm was used to estimate the system's frequency, together with the positive and the negative sequences of the three-phase utility grid voltages when unbalanced sags occurred. The current control was made in a stationary reference frame by using proportional-resonant regulators, and a DC voltage source was used to emulate the primary energy from any type of renewable system. The validation of the proposed control algorithm was conducted for a three-phase grid-connected renewable system with an apparent power of 500 kVA. The results from several experimental tests demonstrated the proper behavior of the enhanced algorithm.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] A Novel Low Voltage Ride-Through Technique of Three-Phase Grid-Connected Inverters Based on a Nonlinear Phase-Locked Loop
    Sun, Guangyu
    Li, Yongli
    Jin, Wei
    Li, Song
    Gao, Yan
    IEEE ACCESS, 2019, 7 : 66609 - 66622
  • [22] Enhancing low voltage ride-through capability of grid-connected photovoltaic plants using superconducting fault current limiters
    Li, Chao
    Wu, Qi
    Xin, Ying
    Li, Bin
    RENEWABLE ENERGY, 2024, 231
  • [23] Power-Angle Synchronization for Grid-Connected Converter With Fault Ride-Through Capability for Low-Voltage Grids
    Mukherjee, Subhajyoti
    Chowdhury, Vikram Roy
    Shamsi, Pourya
    Ferdowsi, Mehdi
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2018, 33 (03) : 970 - 979
  • [24] A low-voltage ride-through strategy using mixed potential function for three-phase grid-connected PV systems
    Wen, Hao
    Fazeli, Meghdad
    ELECTRIC POWER SYSTEMS RESEARCH, 2019, 173 : 271 - 280
  • [25] Low-voltage ride-through of a droop-based three-phase four-wire grid-connected microgrid
    Sadeghkhani, Iman
    Golshan, Mohamad Esmail Hamedani
    Mehrizi-Sani, Ali
    Guerrero, Josep M.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (08) : 1906 - 1914
  • [26] Fault ride through control of PV grid-connected inverter with current-limited capability under unbalanced grid voltage conditions
    Guo, Xiaoqiang
    Liu, Wenzhao
    Wang, Baocheng
    Lu, Zhigang
    Sun, Xiaofeng
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (20): : 5155 - 5162
  • [27] Modeling and Control of a Three-phase Grid-connected Inverter under Fault Conditions
    Rolan, Alejandro
    Gimenez, Pablo
    Yague, Sauro J.
    Bogrra, Santiago
    2018 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2018, : 479 - 484
  • [28] Frequency- adaptive control of a three-phase single-stage grid-connected photovoltaic system under grid voltage sags
    Rey-Boue, Alexis B.
    Guerrero-Rodriguez, N. F.
    Stoeckl, Johannes
    Strasser, Thomas, I
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 125 (125)
  • [29] Enhanced Control Scheme for a Three-Phase Grid-Connected PV Inverter under Unbalanced Fault Conditions
    Abbasi, Saeid
    Ghadimi, Ali Asghar
    Abolmasoumi, Amir Hossein
    Reza Miveh, Mohammad
    Jurado, Francisco
    ELECTRONICS, 2020, 9 (08) : 1 - 24
  • [30] Research on the Control Technique of Low Voltage Ride-through for Grid-connected Photovoltaic Inverter
    Zhang, Ying
    Cao, Dufeng
    Yang, Zilong
    Wang, Yibo
    Xu, Honghua
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,