Residential air-source heat pump with refrigerant injection and variable speed compressor: Experimental investigation and compressor modeling

被引:20
|
作者
Dechesne, Bertrand J. [1 ]
Tello-Oquendo, Fernando M. [2 ]
Gendebien, Samuel [1 ]
Lemort, Vincent [1 ]
机构
[1] Univ Liege, Aerosp & Mech Dept, Appl Thermodynam Lab, Allee Decouverte 17, B-4000 Liege, Belgium
[2] Univ Politecn Valencia, Inst Univ Invest Ingn Energet, Camino Vera S-N, E-46022 Valencia, Spain
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2019年 / 108卷
关键词
Experimental; Air source heat pump; Refrigerant injection; Compressor modeling; Variable speed; Superheat; VAPOR-INJECTION; SCROLL COMPRESSOR; PERFORMANCE; SYSTEM; LIQUID; TEMPERATURE; R410A; CYCLE; GAS;
D O I
10.1016/j.ijrefrig.2019.08.034
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents an experimental study of a residential heat pump working with a variable speed scroll compressor with refrigerant injection and R410A as the working fluid. The experimental campaign is aimed at investigating the performance of the scroll compressor under different evaporating and condensing temperatures and rotational speeds. This campaign helped appropriate mathematical expressions to be chosen for an empirical compressor model that is presented in this study. Moreover, the impact of the superheat at the suction and injection ports is investigated for several compressor speeds and working conditions. Decreasing the evaporator superheat from 15 to 5K helped to increase the COP and heating capacity by 9.3% and 12.6% on average respectively, and to decrease the discharge temperature by 6K on average. Decreasing the injection superheat had no impact on the COP but helped to increase the heating capacity by 3.5% and decrease the discharge temperature by an additional 7K. The coupling of the injection and suction superheat control is also presented and offers perspectives for advanced expansion valve control of the injection cycle. Finally, an empirical model of the compressor is presented. This model is based on five dimensionless relations and shows good accuracy in predicting the compressor mass flow rates, electrical consumption and discharge temperature. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:79 / 90
页数:12
相关论文
共 50 条
  • [41] Experimental Investigation into the Effect of Oil Injection on the Performance of a Variable Speed Twin-Screw Compressor
    He, Zhilong
    Wang, Tao
    Wang, Xiaolin
    Peng, Xueyuan
    Xing, Ziwen
    ENERGIES, 2018, 11 (06):
  • [42] Theoretical and experimental investigation on the rolling piston compressor with enhance vapor injection for heat pump system
    Zeng, Wang
    Pan, Xi
    Chen, Jianye
    Ye, Jianjun
    Xie, Junlong
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 153 : 10 - 18
  • [43] The experimental analysis of the effect of ambient factors on the defrosting of economised vapour injection compressor air source heat pump in marine climates
    Huang, M. J.
    Hewitt, N. J.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (03): : 820 - 827
  • [44] Experimental performance of a heat pump driven by vapor injection linear compressor
    Tang, Zuohang
    Li, Xuan
    Zou, Huiming
    Tang, Mingsheng
    Tian, Changqing
    APPLIED THERMAL ENGINEERING, 2023, 225
  • [45] Development and field demonstration of residential air source integrated heat pump using a three-stage compressor☆
    Hu, Yifeng
    Shen, Bo
    ENERGY AND BUILDINGS, 2025, 328
  • [46] Investigation on the air-source chemisorption heat pump for the severely cold regions
    Gao, Peng
    Wang, Liwei
    APPLIED THERMAL ENGINEERING, 2020, 179
  • [47] Simulation of Air Source Heat Pump with Refrigerant Injection for Heating Operation
    Liu Haibo
    Shao Shuangquan
    Ma Guoyuan
    Fan Boyuan
    TransactionsofNanjingUniversityofAeronauticsandAstronautics, 2018, 35 (05) : 739 - 748
  • [48] Performance investigation of air-source heat pump heating system with novel thermal storage refrigerant-heated panel
    Shao S.
    Zhang H.
    You S.
    Zheng W.
    Huagong Xuebao/CIESC Journal, 2020, 71 (08): : 3480 - 3489
  • [49] HEAT-PUMP ROOM AIR CONDITIONER USING VARIABLE CAPACITY COMPRESSOR
    UMEZU, K
    SUMA, S
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (12): : 70 - 70
  • [50] Experimental investigation of L41b as replacement for R410A in a residential air-source heat pump water heater
    Qiu, Jinyou
    Zhang, Hua
    Sheng, Jian
    Wu, Zhihong