Residential air-source heat pump with refrigerant injection and variable speed compressor: Experimental investigation and compressor modeling

被引:20
|
作者
Dechesne, Bertrand J. [1 ]
Tello-Oquendo, Fernando M. [2 ]
Gendebien, Samuel [1 ]
Lemort, Vincent [1 ]
机构
[1] Univ Liege, Aerosp & Mech Dept, Appl Thermodynam Lab, Allee Decouverte 17, B-4000 Liege, Belgium
[2] Univ Politecn Valencia, Inst Univ Invest Ingn Energet, Camino Vera S-N, E-46022 Valencia, Spain
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2019年 / 108卷
关键词
Experimental; Air source heat pump; Refrigerant injection; Compressor modeling; Variable speed; Superheat; VAPOR-INJECTION; SCROLL COMPRESSOR; PERFORMANCE; SYSTEM; LIQUID; TEMPERATURE; R410A; CYCLE; GAS;
D O I
10.1016/j.ijrefrig.2019.08.034
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents an experimental study of a residential heat pump working with a variable speed scroll compressor with refrigerant injection and R410A as the working fluid. The experimental campaign is aimed at investigating the performance of the scroll compressor under different evaporating and condensing temperatures and rotational speeds. This campaign helped appropriate mathematical expressions to be chosen for an empirical compressor model that is presented in this study. Moreover, the impact of the superheat at the suction and injection ports is investigated for several compressor speeds and working conditions. Decreasing the evaporator superheat from 15 to 5K helped to increase the COP and heating capacity by 9.3% and 12.6% on average respectively, and to decrease the discharge temperature by 6K on average. Decreasing the injection superheat had no impact on the COP but helped to increase the heating capacity by 3.5% and decrease the discharge temperature by an additional 7K. The coupling of the injection and suction superheat control is also presented and offers perspectives for advanced expansion valve control of the injection cycle. Finally, an empirical model of the compressor is presented. This model is based on five dimensionless relations and shows good accuracy in predicting the compressor mass flow rates, electrical consumption and discharge temperature. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:79 / 90
页数:12
相关论文
共 50 条
  • [11] Experimental investigation of air-source heat pump for cold regions
    Ma, GY
    Chai, QH
    Jiang, Y
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (01): : 12 - 18
  • [12] DEFROST CYCLE PERFORMANCE FOR AN AIR-SOURCE HEAT-PUMP WITH A SCROLL AND A RECIPROCATING-COMPRESSOR
    PAYNE, V
    ONEAL, DL
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (02): : 107 - 112
  • [13] Thermodynamic analysis on the performance of a variable speed scroll compressor with refrigerant injection
    Park, YC
    Kim, Y
    Cho, H
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (08): : 1072 - 1082
  • [14] 'Experimental evaluation of suction valve behavior in a variable speed heat pump compressor'
    Gatecliff, G.W.
    Lewis, S.D.
    Proceedings of the 1990 International Compressor Engineering Conference, 1990,
  • [15] Influence of Refrigerant Properties and Charge Amount on Performance of Reciprocating Compressor in Air Source Heat Pump
    Afshari, Faraz
    Comakli, Omer
    Adiguzel, Nesrin
    Zavaragh, Hadi Ghasemi
    JOURNAL OF ENERGY ENGINEERING, 2017, 143 (01)
  • [16] Performance comparison of liquid, vapor, and liquid-vapor injection of single-screw compressor for an air-source heat pump
    Wen, Qiangyu
    Zhi, Ruiping
    Wu, Yuting
    Lei, Biao
    Du, Yanjun
    AIP ADVANCES, 2024, 14 (05)
  • [17] Investigation of the Interactions between Refrigerant, Flowsheet, and Compressor in Residential Heat Pumps
    Hoeges, Christoph
    Roskosch, Dennis
    Brach, Jona
    Vering, Christian
    Venzik, Valerius
    Mueller, Dirk
    ENERGY TECHNOLOGY, 2023, 11 (02)
  • [18] Modeling and Experimental Investigation of a Variable Speed Drive Water Source Heat Pump
    薛志方
    史琳
    TsinghuaScienceandTechnology, 2010, 15 (04) : 434 - 440
  • [19] Impact of the suction line accumulator on the frost/defrost performance of an air-source heat pump with a scroll compressor
    Nutter, DW
    ONeal, D
    Payne, WV
    ASHRAE TRANSACTIONS 1996, VOL 102, PT 1, 1996, 102 : 284 - 290
  • [20] Experimental investigation of effect of refrigerant gases, compressor lubricant and operating conditions on performance of a heat pump
    Afshari, Faraz
    Sozen, Adnan
    Khanlari, Ataollah
    Tuncer, Azim Dogus
    Ali, Hafiz Muhammad