Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast

被引:129
作者
Albrecht, Moritz H. [1 ]
Scholtz, Jan-Erik [1 ]
Huesers, Kristina [1 ]
Beeres, Martin [1 ]
Bucher, Andreas M. [1 ]
Kaup, Moritz [1 ]
Martin, Simon S. [1 ]
Fischer, Sebastian [1 ]
Bodelle, Boris [1 ]
Bauer, Ralf W. [1 ]
Lehnert, Thomas [1 ]
Vogl, Thomas J. [1 ]
Wichmann, Julian L. [1 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
关键词
Monoenergetic plus; Monochromatic imaging; Computed tomography angiography; Image quality; Dual-energy CT; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; REDUCED IODINE LOAD; CHEST CT; QUALITY; NOISE;
D O I
10.1007/s00330-015-3970-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare quantitative image quality parameters in abdominal dual-energy computed tomography angiography (DE-CTA) using an advanced image-based (Mono+) reconstruction algorithm for virtual monoenergetic imaging and standard DE-CTA. Fifty-five patients (36 men; mean age, 64.2 +/- 12.7 years) who underwent abdominal DE-CTA were retrospectively included. Mono + images were reconstructed at 40, 50, 60, 70, 80, 90 and 100 keV levels and as standard linearly blended M_0.6 images (60 % 100 kV, 40 % 140 kV). The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of the common hepatic (CHA), splenic (SA), superior mesenteric (SMA) and left renal arteries (LRA) were objectively measured. Mono+ DE-CTA series showed a statistically superior CNR for 40, 50, 60, 70 and 80 keV (P < 0.031) compared to M_0.6 images for all investigated arteries except SMA at 80 keV (P = 0.08). CNR at 40 keV revealed a mean relative increase of 287.7 % compared to linearly blended images among all assessed arteries (P < 0.001). SNR of Mono+ images was consistently significantly higher at 40, 50, 60 and 70 keV compared to M_0.6 for CHA and SA (P < 0.009). Compared to linearly blended images, Mono+ reconstructions at low keV levels of abdominal DE-CTA datasets significantly improve quantitative image quality. aEuro cent Mono+ combines increased attenuation with reduced image noise compared to standard DE-CTA. aEuro cent Mono+ shows superior contrast-to-noise ratios at low keV compared to linearly-blended images. aEuro cent Contrast-to-noise ratio in monoenergetic DE-CTA peaks at 40 keV. aEuro cent Mono+ reconstructions significantly improve quantitative image quality at low keV levels.
引用
收藏
页码:1863 / 1870
页数:8
相关论文
共 26 条
[1]   Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography [J].
Apfaltrer, Paul ;
Sudarski, Sonja ;
Schneider, David ;
Nance, John W., Jr. ;
Haubenreisser, Holger ;
Fink, Christian ;
Schoenberg, Stefan O. ;
Henzler, Thomas .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) :322-328
[2]   Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation [J].
Bamberg, Fabian ;
Dierks, Alexander ;
Nikolaou, Konstantin ;
Reiser, Maximilian F. ;
Becker, Christoph R. ;
Johnson, Thorsten R. C. .
EUROPEAN RADIOLOGY, 2011, 21 (07) :1424-1429
[3]   Dual-Energy CT Angiography in Peripheral Arterial Occlusive Disease [J].
Brockmann, Carolin ;
Jochum, Susanne ;
Sadick, Maliha ;
Huck, Kurt ;
Ziegler, Peter ;
Fink, Christian ;
Schoenberg, Stefan O. ;
Diehl, Steffen J. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (04) :630-637
[4]   Substantial iodine volume load reduction in CT angiography with dual-energy imaging: insights from a pilot randomized study [J].
Carrascosa, Patricia ;
Capunay, Carlos ;
Rodriguez-Granillo, Gaston A. ;
Deviggiano, Alejandro ;
Vallejos, Javier ;
Leipsic, Jonathon A. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (08) :1613-1620
[5]   Spectral Optimization of Chest CT Angiography with Reduced Iodine Load: Experience in 80 Patients Evaluated with Dual-Source, Dual-Energy CT [J].
Delesalle, Marie-Aurelie ;
Pontana, Francois ;
Duhamel, Alain ;
Faivre, Jean-Baptiste ;
Flohr, Thomas ;
Tacelli, Nunzia ;
Remy, Jacques ;
Remy-Jardin, Martine .
RADIOLOGY, 2013, 267 (01) :256-266
[6]   High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate [J].
Gordic, Sonja ;
Husarik, Daniela B. ;
Desbiolles, Lotus ;
Leschka, Sebastian ;
Frauenfelder, Thomas ;
Alkadhi, Hatem .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (06) :1173-1179
[7]   Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media [J].
Grant, Katharine L. ;
Flohr, Thomas G. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Thomas, Christoph ;
Schmidt, Bernhard .
INVESTIGATIVE RADIOLOGY, 2014, 49 (09) :586-592
[8]   Assessment of Vascular Contrast and Depiction of Stenoses in Abdominopelvic and Lower Extremity Vasculature: Comparison of Dual-energy MDCT with Digital Subtraction Angiography [J].
Huang, Steven Y. ;
Nelson, Rendon C. ;
Miller, Michael J. ;
Kim, Charles Y. ;
Lawson, Jeffrey H. ;
Husarik, Daniela B. ;
Boll, Daniel T. .
ACADEMIC RADIOLOGY, 2012, 19 (09) :1149-1157
[9]   Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose [J].
Leschka, Sebastian ;
Stolzmann, Paul ;
Schmid, Florian T. ;
Scheffel, Hans ;
Stinn, Bjoern ;
Marincek, Borut ;
Alkadhi, Hatem ;
Wildermuth, Simon .
EUROPEAN RADIOLOGY, 2008, 18 (09) :1809-1817