A non-enzymatic sensor for hydrogen peroxide based on the use of α-Fe2O3 nanoparticles deposited on the surface of NiO nanosheets

被引:46
|
作者
Achari, Divyalakshmi Saravana [1 ]
Santhosh, Chella [2 ]
Deivasegamani, Revathy [1 ]
Nivetha, Ravi [1 ]
Bhatnagar, Amit [2 ]
Jeong, Soon Kwan [3 ]
Grace, Andrews Nirmala [1 ]
机构
[1] VIT Univ, Ctr Nanotechnol Res, Vellore 632014, Tamil Nadu, India
[2] Univ Eastern Finland, Dept Environm & Biol Sci, POB 1627, FI-70211 Kuopio, Finland
[3] Korea Inst Energy Res, Green Energy Proc Lab, 152 Gajeong Ro, Daejeon 34129, South Korea
关键词
NiO/alpha-Fe2O3; Nanocomposites; Non-enzymatic sensor; H2O2; Amperometry; Electrocatalysis; GLASSY-CARBON ELECTRODE; ELECTROCATALYTIC OXIDATION; BIOSENSOR; GRAPHENE; GLUCOSE; HEMOGLOBIN; NANOTUBES; IMMOBILIZATION; NANOWALLS; ALCOHOLS;
D O I
10.1007/s00604-017-2335-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports on the synthesis of nanocomposites from NiO and alpha-Fe2O3 by a hydrothermal route. The material was characterized in terms of structural and morphological features by X-ray diffraction and scanning electron microscopy. The nanocomposites were synthesized by growing alpha-Fe2O3 nanoparticles on the surface of flower-like NiO nanosheets, and then characterized by cyclic voltammetry and amperometric techniques. A glassy carbon electrode (GCE) modified with the nanocomposite displayed distinctly improved response to H2O2 compared to a GCE modified with bare NiO. The H2O2 sensor, best operated at a voltage of 0.4 V (vs. Ag/AgCl) has a sensitivity of 146.98 mu A.mu M-1.cm(-2), a 0.05 mM lower detection limit, and a linear working range that extends from 0.5 to 3 mM of H2O2. The sensor is reproducible and long-term stable even in the presence of various interfering molecules such as ascorbic acid and uric acid.
引用
收藏
页码:3223 / 3229
页数:7
相关论文
共 50 条
  • [41] A sensitive nonenzymatic hydrogen peroxide sensor based on Fe3O4-Fe2O3 nanocomposites
    Cao, Guang Sheng
    Wang, Peilong
    Li, Xin
    Wang, Yue
    Wang, Guilong
    Li, Junping
    BULLETIN OF MATERIALS SCIENCE, 2015, 38 (01) : 163 - 167
  • [42] Non-enzymatic glucose sensor fabricated by CoFe2O4 nanosheets grown on Reduced Graphene Oxide
    Dong, Min
    Hu, Hongli
    Ding, Shujiang
    Duan, Yujie
    Cui, Chenhui
    MATERIALS TECHNOLOGY, 2022, 37 (14) : 3184 - 3193
  • [43] Non-enzymatic hydrogen peroxide sensor using an electrode modified with iron pentacyanonitrosylferrate nanoparticles
    Habib Razmi
    Rahim Mohammad-Rezaei
    Microchimica Acta, 2010, 171 : 257 - 265
  • [44] Fabrication of Non-Enzymatic Electrochemical Hydrogen Peroxide Sensor Based on Ag NPs/Co3O4/ERGO Composite
    Mirzaei, Mohammad
    Behboudnia, Mahdi
    Kheiri, Farshad
    Chianeh, Vahid Abbasi
    Naeim, Haleh
    Jannatdoust, Elham
    Sirousazar, Mohammad
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (13) : B1232 - B1237
  • [45] Highly Dispersed NiO Nanoparticles Decorating graphene Nanosheets for Non-enzymatic Glucose Sensor and Biofuel Cell
    Zeng, Guisheng
    Li, Weiping
    Ci, Suqin
    Jia, Jingchun
    Wen, Zhenhai
    SCIENTIFIC REPORTS, 2016, 6
  • [46] Non-enzymatic amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with gold nanoparticles deposited on CVD-grown graphene
    Yuan, Yawen
    Zheng, Yiqun
    Liu, Jinglei
    Wang, Hua
    Hou, Shifeng
    MICROCHIMICA ACTA, 2017, 184 (12) : 4723 - 4729
  • [47] A nanocomposite-based electrochemical sensor for non-enzymatic detection of hydrogen peroxide
    Du, Xin
    Chen, Yuan
    Dong, Wenhao
    Han, Bingkai
    Liu, Min
    Chen, Qiang
    Zhou, Jun
    ONCOTARGET, 2017, 8 (08) : 13039 - 13047
  • [48] Non-enzymatic glucose sensor based on facial hydrothermal synthesized NiO nanosheets loaded on glassy carbon electrode
    Wang, Shutao
    Wang, Cong
    Wei, Guijuan
    Xiao, Huaqing
    An, Ning
    Zhou, Yan
    An, Changhua
    Zhang, Jun
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2016, 509 : 252 - 258
  • [49] In-situ synthesis of ultrafine Cu2O nanoparticles onto MnO2 nanosheets for efficient non-enzymatic electrochemical sensing of hydrogen peroxide
    Xiang, Wei
    Lei, Ming
    Wang, Shangbing
    Zhang, Wangbing
    Dong, Yongping
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2023, 53 (09) : 1777 - 1785
  • [50] Development of non-enzymatic cholesterol bio-sensor based on TiO2 nanotubes decorated with Cu2O nanoparticles
    Khaliq, Nilem
    Rasheed, Muhammad Asim
    Cha, Gihoon
    Khan, Maaz
    Karim, Shafqat
    Schmuki, Patrik
    Ali, Ghafar
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 302