Complications after Posterior Lamellar Keratoplasty (DSAEK): Prevention, Detection and Treatment

被引:7
作者
Heindl, L. M. [1 ]
Kruse, F. E. [1 ]
Cursiefen, C. [1 ]
机构
[1] Univ Klinikums Erlangen, Augenklin, D-91054 Erlangen, Germany
关键词
cornea; conjunctiva; cataract; posterior lamellar keratoplasty; DSAEK; DMEK; AUTOMATED ENDOTHELIAL KERATOPLASTY; GRAFT-REJECTION EPISODES; PENETRATING KERATOPLASTY; DONOR TISSUE; SURGERY;
D O I
10.1055/s-0029-1245447
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to outline typical complications after Descemet's stripping automated endothelial keratoplasty (DSAEK) and to discuss their prevention and management. Methods: Our own clinical results and PUBMED literature search were evaluated. Results: Postoperative flap dislocation, which can be effectively treated by re-bubbling the graft, is the most common and typical complication after DSAEK. Conclusions: Careful preoperative indication, surgery and postoperative care make DSAEK a safe and effective new therapeutic option for patients with endothelial corneal disease.
引用
收藏
页码:478 / 482
页数:5
相关论文
共 25 条
[1]   Cytomegalovirus Endotheliitis in Descemet's Stripping Endothelial Keratoplasty [J].
Anshu, Arundhati ;
Chee, Soon-Phaik ;
Mehta, Jodhbir S. ;
Tan, Donald T. H. .
OPHTHALMOLOGY, 2009, 116 (04) :624-630
[2]   Patient satisfaction after posterior lamellar keratoplasty (DSAEK) [J].
Bachmann, B. O. ;
Pogorelov, P. ;
Kruse, F. E. ;
Cursiefen, C. .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2008, 225 (06) :577-581
[3]   Retrospective Contralateral Study Comparing Descemet Stripping Automated Endothelial Keratoplasty With Penetrating Keratoplasty [J].
Bahar, Irit ;
Kaiserman, Igor ;
Levinger, Eliya ;
Sansanayudh, Wiwan ;
Slomovic, Allan R. ;
Rootman, David S. .
CORNEA, 2009, 28 (05) :485-488
[4]   Endokeratoplasty as an alternative to penetrating keratoplasty for the surgical treatment of diseased endothelium - Initial results [J].
Busin, M ;
Arffa, RC ;
Sebastiani, A .
OPHTHALMOLOGY, 2000, 107 (11) :2077-2082
[5]   Descemet's stripping with automated endothelial keratoplasty (DSAEK) [J].
Cursiefen, C. ;
Kruse, F. E. .
OPHTHALMOLOGE, 2008, 105 (02) :183-+
[6]   Changing indications for penetrating keratoplasty: Histopathology of 1,250 corneal buttons [J].
Cursiefen, C ;
Kuchle, M ;
Naumann, GOH .
CORNEA, 1998, 17 (05) :468-470
[7]   Descemet's stripping automated endothelial keratoplasty (DSAEK) [J].
Cursiefen, C. ;
Kruse, F. E. .
OPHTHALMOLOGE, 2009, 106 (10) :939-952
[8]   Long-term refractive and visual outcome after penetrating keratoplasty only versus the triple procedure in Fuchs' dystrophy [J].
Das, Sujata ;
Langenbucher, Achim ;
Jacobi, Christina ;
Nguyen, Nhung X. ;
Kruse, Friedrich E. ;
Naumann, Gottfried O. H. ;
Seitz, Berthold .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (09) :1089-1095
[9]   Descemet-stripping automated endothelial keratoplasty [J].
Gorovoy, Mark S. .
CORNEA, 2006, 25 (08) :886-889
[10]   Visual Rehabilitation Rate After Isolated Descemet Membrane Transplantation Descemet Membrane Endothelial Keratoplasty [J].
Ham, Lisanne ;
Balachandran, Chandra ;
Verschoor, Christianne A. ;
van der Wees, Jacqueline ;
Melles, Gerrit R. J. .
ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (03) :252-255