Oil removing efficiency in oil-water separation flotation column

被引:15
作者
Xu, Hongxiang [1 ]
Liu, Jiongtian [1 ]
Wang, Yongtian [2 ]
Cheng, Gan [2 ]
Deng, Xiaowei [1 ]
Li, Xiaobing [2 ]
机构
[1] China Univ Min & Technol, Sch Chem Engn & Technol, Xuzhou 221116, Jiangsu, Peoples R China
[2] Chinese Natl Engn Res Ctr Coal Preparat & Purific, Xuzhou 221116, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Oil-water separation flotation column; Cyclonic section; Oil removing efficiency; Airflotation section; SYSTEM;
D O I
10.1080/19443994.2014.908413
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
An oil-water separation flotation column with a unique structure was used in oil-water separation fields. The oil-water separation flotation column contains the cyclonic separation and airflotation separation with advantages in the oily sewage treatment field such as low effective separation size, short separation time, large handling capacity, and low operating cost, especially in polymer-flooding-drive oily sewage treatment aspect. In this paper, the oil removal efficiencies of the cyclonic and airflotation sections of the oil-water separation flotation column were investigated. In addition, several operating parameters which impact separation such as feeding speed, aeration rate, circulating pressure, underflow split ratio, frother consumption were also investigated. The optimum operating parameters determined for the oil-water separation flotation column were a feeding speed of 1.50 m(3) h(-1), an aeration rate of 2.50 m(3) h(-1), and a circulating pressure of 0.28 MPa. A bottom flow diversion ratio of 95% and final effluent oil content of 16.49 mg L-1 were also determined. Furthermore, three separation models for the cyclonic section separation, the airflotation section separation and the whole column separation were constructed.
引用
收藏
页码:2456 / 2463
页数:8
相关论文
共 18 条
[1]   Modified column flotation of adsorbing iron hydroxide colloidal precipitates [J].
Capponi, F. ;
Sartori, M. ;
Souza, M. L. ;
Rubio, J. .
INTERNATIONAL JOURNAL OF MINERAL PROCESSING, 2006, 79 (03) :167-173
[2]  
杜以兵, 1999, [油气田地面工程, Oil-gasfield Surface Engineering], V18, P32
[3]   Review of pollutants removed by electrocoagulation and electrocoagulation/flotation processes [J].
Emamjomeh, Mohammad. M. ;
Sivakumar, Muttucumaru .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2009, 90 (05) :1663-1679
[4]  
Gao G. C., 2000, CHINA OFFSHORE OIL G, V12, P57
[5]   A novel flotation column for oily water cleanup [J].
Gu, XQ ;
Chiang, SH .
SEPARATION AND PURIFICATION TECHNOLOGY, 1999, 16 (03) :193-203
[6]   Enhanced separation of water quality parameters in the DAF (Dissolved Air Flotation) system using ozone [J].
Lee, Byoung-Ho ;
Song, Won-Chul ;
Kim, Hye-Young ;
Kim, Jeong-Hyeon .
WATER SCIENCE AND TECHNOLOGY, 2007, 56 (10) :149-155
[7]  
LI XB, 2007, CHINA U MIN TECHNOL, V17, P546, DOI DOI 10.1016/S1006-1266(07)60143-6
[8]   Cyclonic separation process intensification oil removal based on microbubble flotation [J].
Liu Jiongtian ;
Xu Hongxiang ;
Li Xiaobing .
INTERNATIONAL JOURNAL OF MINING SCIENCE AND TECHNOLOGY, 2013, 23 (03) :415-422
[9]   Characterization of micro-bubble size distribution and flow configuration in DAF contact zone by a non-intrusive image analysis system and tracer tests [J].
Moruzzi, R. B. ;
Reali, M. A. P. .
WATER SCIENCE AND TECHNOLOGY, 2010, 61 (01) :253-262
[10]  
Niu Y. B., 2001, SPE INT S OILF CHEM, P589