Automated volumetric segmentation of retinal fluid on optical coherence tomography

被引:67
作者
Wang, Jie [1 ,2 ]
Zhang, Miao [1 ]
Pechauer, Alex D. [1 ]
Liu, Liang [1 ]
Hwang, Thomas S. [1 ]
Wilson, David J. [1 ]
Li, Dengwang [2 ]
Jia, Yali [1 ]
机构
[1] Oregon Hlth & Sci Univ, Casey Eye Inst, Portland, OR 97239 USA
[2] Shandong Normal Univ, Shandong Prov Key Lab Med Phys & Image Proc Techn, Jinan 250014, Peoples R China
关键词
DIABETIC MACULAR EDEMA; AMPLITUDE-DECORRELATION ANGIOGRAPHY; IMAGES; THICKNESS; ABNORMALITIES; RETINOPATHY; ALGORITHM; TEXTURE; MOTION;
D O I
10.1364/BOE.7.001577
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We propose a novel automated volumetric segmentation method to detect and quantify retinal fluid on optical coherence tomography (OCT). The fuzzy level set method was introduced for identifying the boundaries of fluid filled regions on B-scans (x and y-axes) and C-scans (z-axis). The boundaries identified from three types of scans were combined to generate a comprehensive volumetric segmentation of retinal fluid. Then, artefactual fluid regions were removed using morphological characteristics and by identifying vascular shadowing with OCT angiography obtained from the same scan. The accuracy of retinal fluid detection and quantification was evaluated on 10 eyes with diabetic macular edema. Automated segmentation had good agreement with manual segmentation qualitatively and quantitatively. The fluid map can be integrated with OCT angiogram for intuitive clinical evaluation. (C) 2016 Optical Society of America
引用
收藏
页码:1577 / 1589
页数:13
相关论文
共 41 条
[31]   Patterns of diabetic macular edema with optical coherence tomography [J].
Otani, T ;
Kishi, S ;
Maruyama, Y .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 127 (06) :688-693
[32]   Three-Dimensional Analysis of Retinal Layer Texture: Identification of Fluid-Filled Regions in SD-OCT of the Macula [J].
Quellec, Gwenole ;
Lee, Kyungmoo ;
Dolejsi, Martin ;
Garvin, Mona K. ;
Abramoff, Michael D. ;
Sonka, Milan .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (06) :1321-1330
[33]  
Regatieri CV, 2012, RETINA-J RET VIT DIS, V32, P563, DOI [10.1097/IAE.0B013E31822F5678, 10.1097/IAE.0b013e31822f5678]
[34]   Automated detection of clinically signifficant macular edema by grid scanning optical coherence tomography [J].
Sadda, Srinivas R. ;
Tan, Ou ;
Walsh, Alexander C. ;
Schuman, Joel S. ;
Varma, Rohit ;
Huang, David .
OPHTHALMOLOGY, 2006, 113 (07) :1187-1196
[35]   Efficient reduction of speckle noise in Optical Coherence Tomography [J].
Szkulmowski, Maciej ;
Gorczynska, Iwona ;
Szlag, Daniel ;
Sylwestrzak, Marcin ;
Kowalczyk, Andrzej ;
Wojtkowski, Maciej .
OPTICS EXPRESS, 2012, 20 (02) :1337-1359
[36]   Central serous chorioretinopathy [J].
Wang, Maria ;
Munch, Inger Christine ;
Hasler, Pascal W. ;
Pruente, Christian ;
Larsen, Michael .
ACTA OPHTHALMOLOGICA, 2008, 86 (02) :126-145
[37]   Injection of tissue plasminogen activator into a branch retinal vein in eyes with central retinal vein occlusion [J].
Weiss, JN ;
Bynoe, LA .
OPHTHALMOLOGY, 2001, 108 (12) :2249-2257
[38]   Automated Segmentation of Intraretinal Cystoid Fluid in Optical Coherence Tomography [J].
Wilkins, Gary R. ;
Houghton, Odette M. ;
Oldenburg, Amy L. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (04) :1109-1114
[39]   Ophthalmic fundus imaging: Today and beyond [J].
Yannuzzi, LA ;
Ober, MD ;
Slakter, JS ;
Spaide, RF ;
Fisher, YL ;
Flower, RW ;
Rosen, R .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (03) :511-524
[40]   Advanced image processing for optical coherence tomographic angiography of macular diseases [J].
Zhang, Miao ;
Wang, Jie ;
Pechauer, Alex D. ;
Hwang, Thomas S. ;
Gao, Simon S. ;
Liu, Liang ;
Liu, Li ;
Bailey, Steven T. ;
Wilson, David J. ;
Huang, David ;
Jia, Yali .
BIOMEDICAL OPTICS EXPRESS, 2015, 6 (12) :4661-4675