Is small cusp size a limitation for aortic valve repair?

被引:16
作者
Komiya, Tatsuhiko [1 ]
Shimamoto, Takeshi [1 ]
Nonaka, Michihito [1 ]
Matsuo, Takehiko [1 ]
机构
[1] Kurashiki Cent Hosp, Dept Cardiovasc Surg, 1-1-1 Miwa, Kurashiki, Okayama 7108602, Japan
关键词
Aortic valve repair; Geometric height; Computed tomography; Annulus cusp mismatch; Coaptation length; ANNULOPLASTY; ROOT; SUTURE;
D O I
10.1093/ejcts/ezz053
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: We sought to investigate cusp size limitations for valve repair in patients with aortic regurgitation (AR). METHODS: Preoperative computed tomography was performed in 105 patients. Cusp geometric height (GH) and annulus size were measured. Mean patient age was 60.7 +/- 13.7 years. Mean GH of 3 cusps was used in the analysis. Annulus cusp mismatch was graded using predicted coaptation length. Patients were categorized by mean GH into group S (GH <16 mm; n = 35) or L (GH >16 mm; n = 70). RESULTS: Preoperative mean GH was 17.1 +/- 2.3 mm. GH and body height were significantly correlated (r = 0.61). Intraoperative mean GH (18.8 +/- 2.2 mm) was larger than preoperative mean GH (P < 0.0001). However, postoperative (17.1 +/- 2.0 mm) and preoperative mean GH did not differ. Moderate AR was not present on predischarge echocardiography. Mild AR was observed in 51% and 17% of patients in groups S and L, respectively (P = 0.006). During follow-up, moderate or severe AR was observed in 14% and 10% of patients in groups S and L, respectively ( P = 0.74). Two patients in group S required reoperation for a regurgitant valve. Twenty (83%) and 15 (21%) patients in groups S and L, respectively, had severe annulus cusp mismatch before surgery. Annulus cusp mismatch resolved in most patients in group L postoperatively, whereas more than half the patients in group S still had severe mismatch. CONCLUSIONS: Small cusp size (GH <16 mm) is not necessarily a contraindication in aortic valve repair. However, most patients in this group had annulus cusp mismatch. Root replacement or secure annulus plication is mandatory to correct annulus cusp mismatch.
引用
收藏
页码:497 / 502
页数:6
相关论文
共 13 条
  • [1] Aortic root and cusp configuration determine aortic valve function
    Bierbach, Benjamin Oliver
    Aicher, Diana
    Abu Issa, Omar
    Bomberg, Hagen
    Graeber, Stefan
    Glombitza, Petra
    Schaefers, Hans-Joachim
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 38 (04) : 400 - 406
  • [2] Repair-oriented classification of aortic insufficiency: Impact on surgical techniques and clinical outcomes
    Boodhwani, Munir
    de Kerchove, Laurent
    Glineur, David
    Poncelet, Alain
    Rubay, Jean
    Astarci, Parla
    Verhelst, Robert
    Noirhomme, Philippe
    El Khoury, Gebrine
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (02) : 286 - 294
  • [3] Free margin length and coaptation surface area in normal tricuspid aortic valve: an anatomical study
    De Kerchove, Laurent
    Momeni, Mona
    Aphram, Gaby
    Watremez, Christine
    Bollen, Xavier
    Jashari, Ramadan
    Boodhwani, Munir
    Astarci, Parla
    Noirhomme, Philippe
    El Khoury, Gebrine
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (05) : 1040 - 1048
  • [4] The role of annular dimension and annuloplasty in tricuspid aortic valve repair
    de Kerchove, Laurent
    Mastrobuoni, Stefano
    Boodhwani, Munir
    Astarci, Parla
    Rubay, Jean
    Poncelet, Alain
    Vanoverschelde, Jean-Louis
    Noirhomme, Philippe
    El Khoury, Gebrine
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (02) : 428 - 438
  • [5] Aortic cusp sizers to establish the functional classification of aortic insufficiency: algorithm and midterm outcome of operative repair
    Izzat, Mohammad Bashar
    Hamzeh, Khaled
    Mahmoud, Fadi
    Bakour, Mohammad M.
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 21 (01) : 77 - 80
  • [6] Surgical Anatomy of the Aortic Annulus: Landmarks for External Annuloplasty in Aortic Valve Repair
    Khelil, Nizar
    Sleilaty, Ghassan
    Palladino, Michele
    Fouda, Mahmoud
    Escande, Remi
    Debauchez, Mathieu
    Di Centa, Isabelle
    Lansac, Emmanuel
    [J]. ANNALS OF THORACIC SURGERY, 2015, 99 (04) : 1220 - 1226
  • [7] Aortic prosthetic ring annuloplasty: a useful adjunct to a standardized aortic valve-sparing procedure?
    Lansac, E
    Di Centa, I
    Bonnet, N
    Leprince, P
    Rama, A
    Acar, C
    Pavie, A
    Gandjbakhch, I
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 29 (04) : 537 - 543
  • [8] Aortic valve repair with autologous pericardial patch
    Lausberg, Henning F.
    Aicher, Diana
    Langer, Frank
    Schaefers, Hans-Joachim
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 30 (02) : 244 - 249
  • [9] Early results of a novel technique for ring-reinforced aortic valve and root restoration
    Mazzitelli, Domenico
    Noebauer, Christian
    Rankin, J. Scott
    Badiu, Catalin C.
    Dorfmeister, Magdalena
    Crooke, Philip S.
    Wagner, Anke
    Schreiber, Christian
    Lange, Ruediger
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2014, 45 (03) : 426 - 430
  • [10] Cusp height in aortic valves
    Schaefers, Hans-Joachim
    Schmied, Wolfram
    Marom, Gil
    Aicher, Diana
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 146 (02) : 269 - 274