Unicompartmental knee prosthesis implantation with a non-image-based navigation system: rationale, technique, case-control comparative study with a conventional instrumented implantation

被引:76
作者
Jenny, JY [1 ]
Boeri, C [1 ]
机构
[1] Ctr Traumatol & Othoped, F-67400 Illkirch Graffenstaden, France
关键词
knee; unicompartmental prosthesis; navigation system;
D O I
10.1007/s00167-002-0333-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The accuracy of implantation is an accepted prognostic factor for the long-term survival of unicompartmental knee prostheses (UKP). We developed a non-image-guided navigation system for UKP implantation without any extramedullary or intramedullary guiding device. The 30 patients operated on with the navigation system (group A) were matched to 30 patients operated on with the conventional technique (group 13) using age, sex, body mass index, preoperative coronal mechanical femorotibial angle, and severity of the preoperative degenerative changes. All patients had a complete radiological examination in the first 3 months after the index procedure, with anteroposterior and lateral plain knee radiographs and anteroposterior and lateral long leg radiographs. Coronal femorotibial mechanical angle and both coronal and sagittal orientations of the femoral and tibial components were measured. There were no significant differences in the mean numerical values of all measured angles except for the sagittal orientation of the tibial component, with a significant excessive posterior tibial slope in group B. There was a significant increase in the rate of prostheses implanted in the desired angular range for all criteria except the coronal mechanical femorotibial angle in group A. An optimal implantation with all optimal items was obtained by 18 cases in group A and 6 cases in group B. Navigated implantation of a UKP with the used, non-image-based system improved the accuracy of the radiological implantation without any significant inconvenience and with little change in the conventional operative technique. The only inconvenience was a 20-min longer operative time. This improvement could be related to a longer survival of such implanted prostheses.
引用
收藏
页码:40 / 45
页数:6
相关论文
共 19 条
[1]  
Ahlb_ack S., 1968, ACTA RADIOL SCAND S, P7, DOI 10.1148/23.1.134
[2]  
Argenson JN, 2001, 68 ANN M AM AC ORTH
[3]   10-year survivorship of metal-backed, unicompartmental arthroplasty [J].
Bert, JM .
JOURNAL OF ARTHROPLASTY, 1998, 13 (08) :901-905
[4]   Unicompartmental knee arthroplasty surgery - 10-year minimum follow-up period [J].
Cartier, P ;
Sanouiller, JL ;
Grelsamer, RP .
JOURNAL OF ARTHROPLASTY, 1996, 11 (07) :782-788
[5]  
Delp SL, 1998, CLIN ORTHOP RELAT R, P49
[6]  
Epinette JA, 1997, UNICOMPARTMENTAL KNE, P243
[7]  
HERNIGOU P, 1996, REV CHIR ORTHOP RE S, V82, P1
[8]  
Jenny JY, 2001, REV CHIR ORTHOP, V87, P645
[9]  
JENNY JY, 2002, IN PRESS J ARTHROPLA
[10]  
Lootvoet L, 1997, Acta Orthop Belg, V63, P94