Application of thiophene-2-carbaldehyde-modified mesoporous silica as a new sorbent for separation and preconcentration of palladium prior to inductively coupled plasma atomic emission spectrometric determination

被引:104
作者
Jamali, Mohammad Reza
Assadi, Yaghoub [1 ]
Shemirani, Farzaneh
Salavati-Niasari, Masoud
机构
[1] Iran Univ Sci & Technol, Dept Analyt Chem, Fac Chem, Tehran, Iran
[2] Univ Tehran, Sch Chem, Univ Coll Sci, Tehran, Iran
[3] Univ Kashan, Dept Chem, Fac Sci, Kashan, Iran
关键词
preconcentration; palladium; modified mesoporous silica (MCM-41); solid phase extraction; ICP-AES;
D O I
10.1016/j.talanta.2006.07.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new and efficient method was described for an easy synthesis of functionalized mesoporous silica (MCM-41) using thiophene-2-carbaldehyde. This new chemically bonded analytical reagent was used as an effective sorbent for the solid phase extraction of palladium(II) ion from aqueous solutions. Conditions for effective adsorption of trace levels of palladium concentration were optimized with respect to different experimental parameters in batch process. Thiourea solution could efficiently elute adsorbed palladium(II) ion from the surface of the sorbent which then was determined by inductively coupled plasma atomic emission spectrometer (ICP-AES). Common coexisting ions did not interfere with the separation and determination. The preconcentration factor was 100 (1 ml elution volume) for a 100 ml sample volume. The limit of detection of the proposed method is 0.2 ng ml(-1). The maximum sorption capacity of sorbent under optimum conditions has been found to be 5 mg of palladium per gram of sorbent. The relative standard deviation under optimum conditions was 3.2% (n = 10). Accuracy and application of the method was estimated by using test samples of natural and synthetic water spiked with different amounts of palladium(II) ion. (c) 2006 Elsevier B.V All rights reserved.
引用
收藏
页码:1524 / 1529
页数:6
相关论文
共 42 条
  • [1] Heavy metals removal from electroplating wastewater by aminopropyl-Si MCM-41
    Algarra, M
    Jiménez, MV
    Rodríguez-Castellón, E
    Jiménez-López, A
    Jiménez-Jiménez, J
    [J]. CHEMOSPHERE, 2005, 59 (06) : 779 - 786
  • [2] The determination of caesium and silver in soil and fungal fruiting bodies by electrothermal atomic absorption spectrometry
    Anderson, P
    Davidson, CM
    Littlejohn, D
    Ure, AM
    Shand, CA
    Cheshire, MV
    [J]. ANALYTICA CHIMICA ACTA, 1996, 327 (01) : 53 - 60
  • [3] A NEW FAMILY OF MESOPOROUS MOLECULAR-SIEVES PREPARED WITH LIQUID-CRYSTAL TEMPLATES
    BECK, JS
    VARTULI, JC
    ROTH, WJ
    LEONOWICZ, ME
    KRESGE, CT
    SCHMITT, KD
    CHU, CTW
    OLSON, DH
    SHEPPARD, EW
    MCCULLEN, SB
    HIGGINS, JB
    SCHLENKER, JL
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (27) : 10834 - 10843
  • [4] Methods for the determination of platinum group elements originating from the abrasion of automotive catalytic converters
    Bencs, L
    Ravindra, K
    Van Grieken, R
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (10) : 1723 - 1755
  • [5] Simultaneous on-line preconcentration and determination of Pt, Rh and Pd in urine, serum and road dust by flow injection combined with inductively coupled plasma time-of-flight mass spectrometry
    Benkhedda, K
    Dimitrova, B
    Infante, HG
    Ivanova, E
    Adams, FC
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (09) : 1019 - 1025
  • [6] Microwave-assisted digestion procedure for the determination of palladium in road dust
    Boch, K
    Schuster, M
    Risse, G
    Schwarzer, M
    [J]. ANALYTICA CHIMICA ACTA, 2002, 459 (02) : 257 - 265
  • [7] The preparation of highly ordered MCM-41 with extremely low surfactant concentration
    Cai, Q
    Lin, WY
    Xiao, FS
    Pang, WQ
    Chen, XH
    Zou, BS
    [J]. MICROPOROUS AND MESOPOROUS MATERIALS, 1999, 32 (1-2) : 1 - 15
  • [8] Preconcentration of traces of gold, silver and palladium on activated carbon and its determination in geological samples by flame AAS after wet ashing
    Chakrapani, G
    Mahanta, PL
    Murty, DSR
    Gomathy, B
    [J]. TALANTA, 2001, 53 (06) : 1139 - 1147
  • [9] Synthesis of imprinted polymer material with palladium ion nanopores and its analytical application
    Daniel, S
    Gladis, JM
    Rao, TP
    [J]. ANALYTICA CHIMICA ACTA, 2003, 488 (02) : 173 - 182
  • [10] Environmental routes for platinum group elements to biological materials - a review
    Ek, KH
    Morrison, GM
    Rauch, S
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 334 : 21 - 38