Dual Energy CT Using Flying Focal Spot and An Anti-Scatter Grid as a Filter

被引:0
作者
Hsieh, S. [1 ]
Bennett, N. [2 ]
Wang, A. [2 ]
机构
[1] Mayo Clin, Rochester, MN USA
[2] Stanford Univ, Stanford, CA 94305 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
TH-E-TRACK
引用
收藏
页数:1
相关论文
共 50 条
[41]   Sinogram restoration of dual focal spot CT data [J].
Forthmann, Peter ;
Kohler, Thomas ;
Begemann, Philipp ;
Defrise, Michel .
MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
[42]   Anti-scatter grid artifact elimination for high resolution x-ray imaging CMOS detectors [J].
Rana, R. ;
Singh, V. ;
Jain, A. ;
Bednarek, D. R. ;
Rudin, S. .
MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
[43]   Performance study of the anti-scatter grid for sub-megavolt X- ray flash radiography [J].
Liu Wen-jie ;
Liu Jun ;
Xiao Zhiqiang .
APPLIED MECHANICS AND MATERIALS I, PTS 1-3, 2013, 275-277 :1994-1997
[44]   Impact of anti-scatter grid design image quality of CBCT scans for head and neck cancer imaging [J].
Stankovic, U. ;
Van Herk, M. ;
Ploeger, L. S. ;
Van Kranen, S. ;
Sonke, J. J. .
RADIOTHERAPY AND ONCOLOGY, 2014, 111 :S265-S265
[45]   The determination of the optimal strip-thickness of anti-scatter grids for a given grid ratio and strip height [J].
Zhou, Abel ;
Yin, Yuming ;
Tan, Qi ;
White, Graeme L. ;
Davidson, Rob .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2020, 30 (04) :916-925
[46]   Micromachined anti-scatter grid fabricated using crystalline wet etching of (110) silicon and metal electroplating for X-ray imaging [J].
Jeong, Dae-Hun ;
Kim, Jae Myung ;
Noh, Do Young ;
Kim, Kwang Hyun ;
Lee, Jong-Hyun .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01) :846-849
[47]   A New Statistical Iterative Reconstruction Algorithm for a CT Scanner with Flying Focal Spot [J].
Cierniak, Robert ;
Pluta, Piotr .
ARTIFICIAL INTELLIGENCE AND SOFT COMPUTING (ICAISC 2021), PT II, 2021, 12855 :431-441
[48]   Spectral Modulator with Flying Focal Spot: A New Concept of Full-Scale Multienergy Cone-Beam CT and Simultaneous Scatter Correction [J].
Gao, Hewei ;
Wu, Chengpeng ;
Wang, Sen .
MEDICAL PHYSICS, 2019, 46 (06) :E428-E429
[49]   An analysis of radiation dose reduction in paediatric interventional cardiology by altering frame rate and use of the anti-scatter grid [J].
McFadden, S. L. ;
Hughes, C. M. ;
Mooney, R. B. ;
JWinder, Robert .
JOURNAL OF RADIOLOGICAL PROTECTION, 2013, 33 (02) :433-443
[50]   Anti-scatter grid artifact elimination for high-resolution x-ray imaging detectors without a prior scatter distribution profile [J].
Nagesh, S. V. Setlur ;
Rana, R. ;
Bednarek, D. R. ;
Rudin, S. .
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573