Experimental study on the operating characteristics of refrigerant pumps for solar ejector refrigeration systems

被引:5
作者
Tian, Guoji [1 ]
Zhao, Chengming [2 ]
Zheng, Huifan [1 ]
Fan, Xiaowei [1 ]
机构
[1] Zhongyuan Univ Technol, Sch Energy & Environm, Zhengzhou 451191, Peoples R China
[2] Jiyuan Vocat & Tech Coll, Dept Architecture Engn, Jiyuan 459000, Peoples R China
基金
中国国家自然科学基金;
关键词
Solar ejector refrigeration system; Refrigerant pump; Pump performance; CYCLE; PERFORMANCE;
D O I
10.1016/j.solener.2022.05.003
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A bench performance test for a refrigerant pump was built to analyze the variations among parameters such as flow rate, head, rotational speed, efficiency/total efficiency and power consumption of a multistage centrifugal pump under different working conditions. The study showed that the outlet pressure, differential pressure and power consumption of the pump increased with increasing frequencies at the rated flow rate of 1 m3/h and inlet pressure pc = 0.454 MPa. The total pump efficiency showed a trend toward first increasing and then decreasing, and the maximum value was approximately 27.7%. When the refrigerant pump was at a frequency of 37.5 Hz and the inlet pressure was between 0.338 and 0.523 MPa, the pump outlet pressure and differential pressure decreased with increasing flow rates, and the pump outlet pressure increased with increasing inlet pressures. While the pump differential pressure increased with the increase in suction pressure, the pump power consumption increased with the increase in flow and increased slowly with the pump inlet pressure. With the increase in the flow rate, the total efficiency of the pump showed a tendency toward first increasing and then slowly declining. The total efficiency of the pump was between 4.0% and 30.2% at flow rates between 0 and 1.8 m3/h. Under the same conditions, when the pump operated under low flow rate and high pressure differential conditions, and the refrigerant pump efficiency was low.
引用
收藏
页码:50 / 58
页数:9
相关论文
共 27 条
[1]  
[Anonymous], 2016, 32162016 GBT STAND P
[2]  
[Anonymous], 2010, THESIS SAN DIEGO STA
[3]   INFLUENCE OF ORGANIC WORKING FLUIDS ON THE PERFORMANCE OF A POSITIVE-DISPLACEMENT PUMP WITH SLIDING VANES [J].
BALA, EJ ;
OCALLAGHAN, PW ;
PROBERT, SD .
APPLIED ENERGY, 1985, 20 (02) :153-159
[4]   Solar ejector cooling systems: A review [J].
Braimakis, Konstantinos .
RENEWABLE ENERGY, 2021, 164 :566-602
[5]   Semi-empirical model of a multi-diaphragm pump in an Organic Rankine Cycle (ORC) experimental unit [J].
D'Amico, F. ;
Pallis, P. ;
Leontaritis, A. D. ;
Karellas, S. ;
Kakalis, N. M. ;
Rech, S. ;
Lazzaretto, A. .
ENERGY, 2018, 143 :1056-1071
[6]   An experimental investigation into the integration of a jet-pump refrigeration cycle and a novel jet-spay thermal ice storage system [J].
Eames, Ian W. ;
Worall, Mark ;
Wu, Shenyi .
APPLIED THERMAL ENGINEERING, 2013, 53 (02) :285-290
[7]  
Gao Y, 2020, INT J PHOTOENERGY, V2020, P1
[8]   Performance analysis of PTC field based ejector organic Rankine cycle integrated with a triple pressure level vapor absorption system (EORTPAS) [J].
Gupta, Devendra Kumar ;
Kumar, Rajesh ;
Kumar, Naveen .
ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2020, 23 (01) :82-91
[9]   Experimental analysis of a hybrid system including refrigeration cycle and water desalination with jet pump [J].
Hosseini, A. ;
Noghrehabadi, A. R. ;
Behbahani-nejad, M. .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (02) :1505-1512
[10]  
Lu H.T., 2019, INVESTIGATION WORKIN