Helical CT of the small bowel with an alternative oral contrast material in patients with Crohn disease

被引:62
作者
Doerfler, OC
Ruppert-Kohlmayr, AJ
Reittner, P
Hinterleitner, T
Petritsch, W
Szolar, DH
机构
[1] Univ Hosp Graz, Dept Radiol, A-8036 Graz, Austria
[2] Univ Hosp Graz, Dept Internal Med, A-8036 Graz, Austria
[3] Diagnostikum Graz Sued W, A-8054 Graz, Austria
来源
ABDOMINAL IMAGING | 2003年 / 28卷 / 03期
关键词
helical computed tomography; enteroclysis; small bowel; Crohn disease; Mucofalk;
D O I
10.1007/s00261-002-0040-4
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: We assessed the usefulness of helical computed tomography, (CT) with a negative oral contrast material for detecting Crohn disease. Methods: Thirty-eight patients with proven Crohn disease were examined. We administered a large volume of a new negative oral contrast material (Mucofalk suspended in water) and then proceeded with helical CT scanning. This technique is an alternative to CT and conventional enteroclyses that use a nasojejunal tube. Two radiologists interpreted the scans, and patients were interviewed about their tolerance of the procedure. We created multiplanar reformatted images in all cases. Potential of small bowel distention by Mucofalk was evaluated by two observers on a three-point scale, and interobserver agreement was calculated with kappa statistics. Results: All patients who underwent enteroclysis stated that CT was the more comfortable method, the taste of the peroral contrast medium was considered good by 52.6% and acceptable by 47.4%. Small bowel distention was excellent in 55% of cases, moderate in 26%, and poor in 19%, with an interoberserver agreement of 78%. CT findings correlated with enteroclysis in 27 patients who underwent both methods. Analysis of CT versus enteroclysis showed a sensitivity of 89% for CT versus 78% for small bowel enteroclysis. Conclusion: Mucofalk CT is a simple, rapid, noninvasive, and accurate method of evaluating extramucosal manifestations of Crohn disease. The tubeless procedure improved patients' comfort and decreased time, cost, and radiation exposure.
引用
收藏
页码:313 / 318
页数:6
相关论文
共 16 条
  • [1] CT OF THE BOWEL - USE OF WATER TO ENHANCE DEPICTION
    ANGELELLI, G
    MACARINI, L
    [J]. RADIOLOGY, 1988, 169 (03) : 848 - 849
  • [2] CT EVALUATION OF CROHNS-DISEASE - EFFECT ON PATIENT-MANAGEMENT
    FISHMAN, EK
    WOLF, EJ
    JONES, B
    BAYLESS, TM
    SIEGELMAN, SS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (03) : 537 - 540
  • [3] COMPUTED-TOMOGRAPHY IN THE EVALUATION OF CROHN DISEASE
    GOLDBERG, HI
    GORE, RM
    MARGULIS, AR
    MOSS, AA
    BAKER, EL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 140 (02) : 277 - 282
  • [4] GORE RM, 1996, AJR, V169, P3
  • [5] CROHN DISEASE IN THE PEDIATRIC-PATIENT - CT EVALUATION
    JABRA, AA
    FISHMAN, EK
    TAYLOR, GA
    [J]. RADIOLOGY, 1991, 179 (02) : 495 - 498
  • [6] Laufer I, 1995, Inflamm Bowel Dis, V1, P228, DOI 10.1002/ibd.3780010310
  • [7] LEVINE JB, 1995, GASTROENTEROL CLIN N, V24, P647
  • [8] MICHELASSI F, 1993, ANN SURG, V218, P666
  • [9] Sonographic assessment of the normal and abnormal bowel wall in nondiverticular ileitis and colitis
    Pradel, JA
    David, XR
    Taourel, P
    Djafari, M
    Veyrac, M
    Bruel, JM
    [J]. ABDOMINAL IMAGING, 1997, 22 (02): : 167 - 172
  • [10] Multiplanar helical CT enterography in patients with Crohn's disease
    Raptopoulos, V
    Schwartz, RK
    McNicholas, MMJ
    Movson, J
    Pearlman, J
    Joffe, N
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (06) : 1545 - 1550