Sequential reconstruction of vessel skeletons from X-ray coronary angiographic sequences

被引:23
作者
Sun Zheng [1 ]
Tian Meiying [1 ]
Sun Jian [2 ]
机构
[1] N China Elect Power Univ, Dept Elect & Commun Engn, Baoding 071003, Hebei, Peoples R China
[2] Hebei Univ Affiliated Hosp, Dept Radiol, Baoding 071003, Peoples R China
关键词
X-ray coronary angiography; Coronary artery; Vessel skeleton; Snake model; Tracking; 3D sequential reconstruction; CORRECT 3-D RECONSTRUCTION; 3-DIMENSIONAL RECONSTRUCTION; BIPLANE ANGIOGRAPHY; ARTERIES; MOTION; TREE; EXTRACTION; CURVATURE; TRACKING; SHAPE;
D O I
10.1016/j.compmedimag.2009.12.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
X-ray coronary angiography (CAG) is one of widely used imaging modalities for diagnosis and interventional treatment of cardiovascular diseases. Dynamic CAG sequences acquired from several viewpoints record coronary arterial morphological information as well as dynamic performances. The aim of this work is to propose a semi-automatic method for sequentially reconstructing coronary arterial skeletons from a pair of CAG sequences covering one or several cardiac cycles acquired from different views based on snake model. The snake curve deforms directly in 3D through minimizing a predefined energy function and ultimately stops at the global optimum with the minimal energy, which is the desired 3D vessel skeleton. The energy function combines intrinsic properties of the curve and acquired image data with a priori knowledge of coronary arterial morphology and dynamics. Consequently, 2D extraction, 3D sequential reconstruction and tracking of coronary arterial skeletons are synchronously implemented. The main advantage of this method is that matching between a pair of angiographic projections in point-by-point manner is avoided and the reproducibility and accuracy are improved. Results are given for clinical image data of patients in order to validate the proposed method. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:333 / 345
页数:13
相关论文
共 45 条
[1]  
Bascle B., 1993, [1993] Proceedings Fourth International Conference on Computer Vision, P421, DOI 10.1109/ICCV.1993.378185
[2]   Reconstruction of coronary arteries from a single rotational X-ray projection sequence [J].
Blondel, C ;
Malandain, G ;
Vaillant, R ;
Ayache, N .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (05) :653-663
[3]   Predictive (Un)distortion model and 3-D reconstruction by biplane snakes [J].
Cañero, C ;
Vilariño, F ;
Mauri, J ;
Radeva, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) :1188-1201
[4]  
Cañero C, 2000, INT C PATT RECOG, P563, DOI 10.1109/ICPR.2000.902982
[5]  
CHEN CW, 1994, IEEE T PATTERN ANAL, V16, P342, DOI 10.1109/34.277589
[6]   3-D reconstruction of coronary arterial tree to optimize angiographic visualization [J].
Chen, SJ ;
Carroll, JD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (04) :318-336
[7]  
CHEN SJ, 1996, P COMP CARD IND, P117
[8]   Kinematic and deformation analysis of 4-D coronary arterial trees reconstructed from cine angiograms [J].
Chen, SYJ ;
Carroll, JD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (06) :710-721
[9]  
Christiaens J, 2001, INT CONGR SER, V1230, P865
[10]   3-D multimodal cardiac data superimposition using 2-D image registration and 3-D reconstruction from multiple views [J].
Daul, Christian ;
Lopez-Hernandez, Juan ;
Wolf, Didier ;
Karcher, Gilles ;
Ethevenot, Gerard .
IMAGE AND VISION COMPUTING, 2009, 27 (06) :790-802