3D CFD simulation and parametric study of a flat plate deflector for vertical axis wind turbine

被引:84
作者
Wong, Kok Hoe [1 ]
Chong, Wen Tong [1 ]
Poh, Sin Chew [1 ]
Shiah, Yui-Chuin [2 ]
Sukiman, Nazatul Liana [1 ]
Wang, Chin-Tsan [3 ]
机构
[1] Univ Malaya, Fac Engn, Dept Mech Engn, Kuala Lumpur 50603, Malaysia
[2] Natl Cheng Kung Univ, Dept Aeronaut & Astronaut, Tainan 701, Taiwan
[3] Natl Ilan Univ, Dept Mech & Electromech Engn, Ilan 260, Taiwan
关键词
Computational fluid dynamics (CFD); Flat plate deflector; Power augmentation; Vertical axis wind turbine; Coefficient of power; Velocity vector; AERODYNAMIC PERFORMANCE; UPSTREAM DEFLECTOR; OUTPUT POWER; H-DARRIEUS; BLADE;
D O I
10.1016/j.renene.2018.05.085
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Three-dimensional numerical simulations have been performed to analyze the aerodynamic characteristics of a straight-bladed NACA0021 vertical axis wind turbine (VAWT). The unsteady flow CFD simulation was validated with the wind tunnel experiment data available in the literature. Sliding mesh method with the SST k-omega turbulence model was employed to simulate the rotational motion of the VAWT using ANSYS Fluent. The study showed a good agreement between the simulation and the wind tunnel testing. Further simulations were carried out to study the effects of a flat plate deflector being placed at the upwind of the VAWT by varying a few parameters including the position, the inclination angle and the length of the flat plate deflector. The simulations showed that the augmented flow occurred at the near wake region where the flow was accelerated and deflected by the deflector before impinging with the turbine; hence the coefficient of power (C-P) of the VAWT improved significantly. However, the performance of the VAWT was highly dependent on the position of the deflector. From the simulation results, with the optimum parameters, the cycle-averaged coefficient of torque was increased about 47.10% higher compared to the VAWT without the deflector. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:32 / 55
页数:24
相关论文
共 33 条
[1]   The use of a curtain design to increase the performance level of a Savonius wind rotors [J].
Altan, Burcin Deda ;
Atilgan, Mehmet .
RENEWABLE ENERGY, 2010, 35 (04) :821-829
[2]  
ANSYS I., 2013, ANSYS FLUENT THEOR G, V15.0
[3]   Dimensionless numbers for the assessment of mesh and timestep requirements in CFD simulations of Darrieus wind turbines [J].
Balduzzi, Francesco ;
Bianchini, Alessandro ;
Ferrara, Giovanni ;
Ferrari, Lorenzo .
ENERGY, 2016, 97 :246-261
[4]   Critical issues in the CFD simulation of Darrieus wind turbines [J].
Balduzzi, Francesco ;
Bianchini, Alessandro ;
Maleci, Riccardo ;
Ferrara, Giovanni ;
Ferrari, Lorenzo .
RENEWABLE ENERGY, 2016, 85 :419-435
[5]   Performance-optimized airfoil for Darrieus wind turbines [J].
Bedon, Gabriele ;
De Betta, Stefano ;
Benini, Ernesto .
RENEWABLE ENERGY, 2016, 94 :328-340
[6]   A computational assessment of the aerodynamic performance of a tilted Darrieus wind turbine [J].
Bedon, Gabriele ;
De Betta, Stefano ;
Benini, Ernesto .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2015, 145 :263-269
[7]   Cross axis wind turbine: Pushing the limit of wind turbine technology with complementary design [J].
Chong, Wen-Tong ;
Muzammil, Wan Khairul ;
Wong, Kok-Hoe ;
Wang, Chin-Tsan ;
Gwani, Mohammed ;
Chu, Yung-Jeh ;
Poh, Sin-Chew .
APPLIED ENERGY, 2017, 207 :78-95
[8]   Comparative CFD analysis of Vertical Axis Wind Turbine in upright and tilted configuration [J].
Chowdhury, Abdullah Mobin ;
Akirnoto, Hirornichi ;
Hara, Yutaka .
RENEWABLE ENERGY, 2016, 85 :327-337
[9]  
De Marco A, 2014, INT J AERO ENG, P2014
[10]   Influence of the deflector plate on the performance of modified Savonius water turbine [J].
Golecha, Kailash ;
Eldho, T. I. ;
Prabhu, S. V. .
APPLIED ENERGY, 2011, 88 (09) :3207-3217