Dosimetric comparison of volumetric modulated arc therapy and linear accelerator-based radiosurgery for the treatment of one to four brain metastases

被引:6
作者
Salkeld, Alison L. [1 ,2 ]
Unicomb, Kylie [1 ]
Hayden, Amy J. [1 ,2 ]
Van Tilburg, Kevin [1 ]
Yau, Shan [1 ,2 ]
Tiver, Kenneth [1 ,2 ]
机构
[1] Nepean Hosp, Nepean Canc Care Ctr, Sydney, NSW, Australia
[2] Westmead Hosp, Crowne Princess Mary Canc Ctr, Wentworthville, NSW 2145, Australia
关键词
brain; linear accelerator radiosurgery; metastasis; radiosurgery; volumetric modulated arc therapy; STEREOTACTIC RADIOSURGERY; RADIATION-THERAPY; BREAST-CANCER; RESECTION CAVITY; PLUS; PREDICTOR; SURGERY; QUALITY;
D O I
10.1111/1754-9485.12188
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The purpose of this study is to compare and evaluate volumetric modulated arc therapy (VMAT) and linear accelerator-based radiosurgery (Linac RS) for the treatment of one to four brain metastases. Methods: Radiotherapy plans for 10 patients with 1 to 4 brain metastases that were planned and treated using conventional Linac RS were replanned using a mono-isocentric VMAT technique using two to four arcs. The same doses, target volumes and organs at risk (OAR) were used in both plans. The plans were evaluated for target volume coverage, dose conformity, homogeneity and dose to OAR. Results: For VMAT plans, 18/19 brain metastases met acceptable Radiation Therapy Oncology Group (RTOG) radiosurgery dose coverage, homogeneity and conformity criteria. There was no observed difference between the mean homogeneity indices for VMAT and Linac RS plans. VMAT plans had a lower mean RTOG conformity index compared with the Linac RS plans (1.10 +/- 0.06 versus 2.06 +/- 1.02). For the OAR, there was no difference in maximal doses to the brain stem, optic chiasm or optic nerves. The volume of normal brain receiving 12 Gy was lower in the VMAT plans (13.3 cm(3) versus 23.1 cm(3)) compared with the Linac RS plans. The mean total number of monitor units (MUs) was 31.3% less in the VMAT plans (5231.2 MU versus 3593.5 MU). Conclusions: Mono-isocentric VMAT plans using two to four arcs meet RTOG radiosurgery quality criteria in patients with one to four brain metastases, with an improvement in conformity and 12-Gy normal brain volume when compared with patients treated with Linac RS at our institution.
引用
收藏
页码:722 / 728
页数:7
相关论文
共 50 条
  • [21] Comparative study of dynamic conformal arc therapy and volumetric modulated arc therapy for treating single brain metastases: A retrospective analysis of dosimetric and clinical outcomes
    Chambrelant, Isabelle
    Jarnet, Delphine
    Le Fevre, Clara
    Kuntz, Laure
    Jacob, Julian
    Jenny, Catherine
    Noe, Georges
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 30
  • [22] Single-Isocenter Volumetric Modulated Arc Therapy vs. CyberKnife M6 for the Stereotactic Radiosurgery of Multiple Brain Metastases
    El Shafie, Rami A.
    Tonndorf-Martini, Eric
    Schmitt, Daniela
    Celik, Aylin
    Weber, Dorothea
    Lang, Kristin
    Koenig, Laila
    Hoene, Simon
    Forster, Tobias
    von Nettelbladt, Bastian
    Adeberg, Sebastian
    Debus, Jurgen
    Rieken, Stefan
    Bernhardt, Denise
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [23] Dosimetric comparison among dynamic conformal arc therapy, coplanar and non-coplanar volumetric modulated arc therapy for single brain metastasis
    Torizuka, Daichi
    Uto, Megumi
    Takehana, Keiichi
    Mizowaki, Takashi
    JOURNAL OF RADIATION RESEARCH, 2021, 62 (06) : 1114 - 1119
  • [24] Changing practice patterns of Gamma Knife versus linear accelerator-based stereotactic radiosurgery for brain metastases in the US
    Park, Henry S.
    Wang, Elyn H.
    Rutter, Charles E.
    Corso, Christopher D.
    Chiang, Veronica L.
    Yu, James B.
    JOURNAL OF NEUROSURGERY, 2016, 124 (04) : 1018 - 1024
  • [25] Linear accelerator based stereotactic radiosurgery for melanoma brain metastases
    Bernard, Mark E.
    Wegner, Rodney E.
    Reineman, Katharine
    Heron, Dwight E.
    Kirkwood, John
    Burton, Steven A.
    Mintz, Arlan H.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2012, 8 (02) : 215 - 221
  • [26] Linear accelerator-based radiosurgery is associated with lower incidence of radionecrosis compared with gamma knife for treatment of multiple brain metastases
    Sebastian, Nikhil T.
    Glenn, Chase
    Hughes, Ryan
    Raval, Raju
    Chu, Jacqueline
    DiCostanzo, Dominic
    Bell, Erica H.
    Grecula, John
    Arnett, Andrea
    Gondal, Hasan
    McGregor, John
    Elder, James B.
    Lonser, Russell
    Chakravarti, Arnab
    Trifiletti, Daniel
    Brown, Paul D.
    Chan, Michael
    Palmer, Joshua D.
    RADIOTHERAPY AND ONCOLOGY, 2020, 147 : 136 - 143
  • [27] Dosimetric study for spine stereotactic body radiation therapy: magnetic resonance guided linear accelerator versus volumetric modulated arc therapy
    Yadav, Poonam
    Musunuru, Hima B.
    Witt, Jacob S.
    Bassetti, Michael
    Bayouth, John
    Baschnagel, Andrew M.
    RADIOLOGY AND ONCOLOGY, 2019, 53 (03) : 362 - 368
  • [28] Strategies to optimize stereotactic radiosurgery plans for brain tumors with volumetric-modulated arc therapy
    Wang, David
    DeNittis, Albert
    Hu, Yibing
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (03): : 45 - 51
  • [29] Dosimetric Comparison of Intensity-Modulated Radiosurgery and Helical Tomotherapy for the Treatment of Multiple Intracranial Metastases
    VanderSpek, Lauren
    Bauman, Glenn
    Wang, Jia-Zhu
    Yartsev, Slav
    Menard, Cynthia
    Cho, Young-Bin
    Mundt, Arno J.
    Lawson, Joshua D.
    Murphy, Kevin T.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2009, 8 (05) : 361 - 367
  • [30] A method for optimizing LINAC treatment geometry for volumetric modulated arc therapy of multiple brain metastases
    Kang, Jun
    Ford, Eric C.
    Smith, Koren
    Wong, John
    McNutt, Todd R.
    MEDICAL PHYSICS, 2010, 37 (08) : 4146 - 4154