Modeling natural convection in a pitched thermosyphon system in building roofs and experimental validation using particle image velocimetry

被引:26
作者
Chami, N. [1 ]
Zoughaib, A. [1 ]
机构
[1] Ecole Mines Paris, CEP, Paris, France
关键词
PIV; Pitched thermosyphon; CFD; Heat transfer; Natural convection; Roof systems; HEATED VERTICAL CHANNEL; SOLAR CHIMNEY; AIR-FLOW; TROMBE WALLS; VENTILATION; EFFICIENCY; FLUX;
D O I
10.1016/j.enbuild.2010.02.019
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Attics in Europe are more and more used as a living room. In tropical regions, summer comfort in attics becomes critical when the roof system is badly designed. The European standards advise to form an open thermosyphon system into the roof under the tiles for many purposes. In order to evaluate the air channel's efficiency, an experimental study using a 2D-PIV system was carried out. A numerical model representing the natural convection within the thermosyphon was also developed. The predicted velocity distributions and the induced mass flow rate were in good agreement with the experimental results. Correlations for the air flow rate and heat transfer coefficients were proposed. The impact of the inclination, height, opening sections and Rayleigh number on the channel's efficiency was also investigated. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1267 / 1274
页数:8
相关论文
共 35 条
[31]   Ventilated-solar roof air flow and heat transfer investigation [J].
Sandberg, M ;
Moshfegh, B .
RENEWABLE ENERGY, 1998, 15 (1-4) :287-292
[32]  
Sandberg M, 1999, Proceedings of HybVent forum, P10
[33]   VERTICAL-CHANNEL NATURAL-CONVECTION SPANNING BETWEEN THE FULLY-DEVELOPED LIMIT AND THE SINGLE-PLATE BOUNDARY-LAYER LIMIT [J].
SPARROW, EM ;
AZEVEDO, LFA .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1985, 28 (10) :1847-1857
[34]   OBSERVED FLOW REVERSALS AND MEASURED-PREDICTED NUSSELT NUMBERS FOR NATURAL-CONVECTION IN A ONE-SIDED HEATED VERTICAL CHANNEL [J].
SPARROW, EM ;
CHRYSLER, GM ;
AZEVEDO, LF .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1984, 106 (02) :325-332
[35]   Optimum wall-to-wall spacing in solar chimney shaped channels in natural convection by numerical investigation [J].
Zamora, B. ;
Kaiser, A. S. .