Neutron production during the interaction of monoenergetic electrons with a Tungsten foil in the radiotherapeutic energy range

被引:18
作者
Gabriela Soto-Bernal, Tzinnia [1 ]
Baltazar-Raigosa, Antonio [2 ]
Medina-Castro, Diego [1 ]
Rene Vega-Carrillo, Hector [3 ]
机构
[1] Univ Autonoma Zacatecas, Unidad Acad Estudios Nucl, Programa Doctorado Ciencias Basicas Ciencias Nucl, Zacatecas, Mexico
[2] Univ Autonoma Zacatecas, Unidad Acad Ingn Elect, Programa Doctorado Ingn & Tecnol Aplicada, Zacatecas, Mexico
[3] Univ Autonoma Zacatecas, Unidad Acad Estudios Nucl, Calle Cipres 10, Zacatecas 98060, Zac, Mexico
关键词
Monoenergetic electrons; Scattering foil; Neutrons; LINAC; Monte Carlo; REFERENCE MONOCHROMATIC FIELDS; MEDICAL LINEAR ACCELERATORS; MONTE-CARLO; INDUCED RADIOACTIVITY; SPECTRA; LINAC; CONTAMINATION; SPECTROMETER; PHOTON; EQUIVALENT;
D O I
10.1016/j.nima.2017.06.027
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The electron, photon, and neutron spectra produced during the interaction between monoenergetic electron beams (8, 10, 12, 15, and 18 MeV) and a 0.05 cm-thick tungsten scattering foil were estimated using Monte Carlo method. Incoming electrons is a pencil beam that after collide with the foil acquires a broader distribution peaked in the same direction of the incoming electrons. Electron spectra show the influence of the binding energy of electrons in the tungsten shells and the increase of the electron fluence. In the interaction between the electrons in the beam and the tungsten atoms in the foil, bremsstrahlung and characteristic photons are produced. These photons are also peaked in the same direction of the incoming beam, and the electron fluence increases as the energy of the electron beam raises. The electron and photon spectra have particles whose energy is larger than the binding energy of neutron in the nucleus. Thus neutron production was noticed for 10, 12, 15, and 18 MeV electron beam. The neutron fluence becomes larger as the energy of the electron beam increases, the neutron spectra are mainly evaporation neutrons for 10 and 12 MeV, and for 15 and 18 MeV knock-on neutrons are also produced. Neutrons are produced in the foil volume having a quasi-isotropic distribution. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 38
页数:12
相关论文
共 40 条
  • [1] Experimental characterization of the neutron spectra generated by a high-energy clinical LINAC
    Amgarou, K.
    Lacoste, V.
    Martin, A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 629 (01) : 329 - 336
  • [2] Neutron Spectrometry With a Passive Bonner Sphere System Around a Medical LINAC and Evaluation of the Associated Unfolding Uncertainties
    Amgarou, Khalil
    Lacoste, Veronique
    Martin, Alain
    Asselineau, Bruno
    Donadille, Laurent
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (05) : 2885 - 2895
  • [3] [Anonymous], 2013, MONTE CARLO TECHNIQU
  • [4] Experimental test of a newly developed single-moderator, multi-detector, directional neutron spectrometer in reference monochromatic fields from 144 keV to 16.5 MeV
    Bedogni, R.
    Gomez-Ros, J. M.
    Pola, A.
    Bortot, D.
    Gentile, A.
    Introini, M. V.
    Buonomo, B.
    Lorenzoli, M.
    Mazzitelli, M.
    Sacco, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 782 : 35 - 39
  • [5] First test of SP2: A novel active neutron spectrometer condensing the functionality of Bonner spheres in a single moderator
    Bedogni, R.
    Bortot, D.
    Buonomo, B.
    Esposito, A.
    Gomnez-Ros, J. M.
    Introini, M. V.
    Lorenzoli, M.
    Pola, A.
    Sacco, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 767 : 159 - 162
  • [6] Testing a newly developed single-sphere neutron spectrometer in reference monochromatic fields from 147 keV to 14.8 MeV
    Bedogni, R.
    Gomez-Ros, J. M.
    Pola, A.
    Introini, M. V.
    Bortot, D.
    Gentile, A.
    Esposito, A.
    Mazzitelli, G.
    Buonomo, B.
    Quintieri, L.
    Foggetta, L.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 714 : 110 - 114
  • [7] Benites J, 2010, AIP CONF PROC, V1310, P44, DOI 10.1063/1.3531604
  • [8] Spectra of photons and neutrons generated in a heterogeneous head of a 15 MV LINAC at differents field sizes
    Benites-Rengifo, J. L.
    Vega-Carrillo, H. R.
    Velazquez-Fernandez, J. B.
    [J]. MEDICAL PHYSICS, 2012, 1494 : 8 - 11
  • [9] Berger M. J, 2017, NATL I STANDARDS TEC
  • [10] MEASUREMENTS OF THERMAL AND RESONANCE NEUTRON FLUENCE AND INDUCED RADIOACTIVITY INSIDE BUNKERS OF MEDICAL LINEAR ACCELERATORS IN THE CENTER OF ONCOLOGY IN OPOLE, POLAND
    Bieniasiewicz, Marcin
    Konefal, Adam
    Wendykier, Jacek
    Orlef, Andrzej
    [J]. ACTA PHYSICA POLONICA B, 2016, 47 (03): : 771 - 776