Creating, transporting, cutting, and merging liquid droplets by electrowetting-based actuation for digital microfluidic circuits

被引:1285
作者
Cho, SK [1 ]
Moon, HJ [1 ]
Kim, CJ [1 ]
机构
[1] Univ Calif Los Angeles, Dept Aerosp & Mech Engn, Los Angeles, CA 90095 USA
基金
美国国家科学基金会;
关键词
contact angle; electrowetting; electrowetting on dielectric (EWOD); lab-on-a-chip; microfluidics; micro total analysis; system (mu TAS); surface tension;
D O I
10.1109/JMEMS.2002.807467
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports the completion of four fundamental fluidic operations considered essential to build digital microfluidic circuits, which can be used for lab-on-a-chip or micro total analysis system (muTAS): 1) creating, 2) transporting, 3) cutting, and 4) merging liquid droplets, all by electrowetting, i.e., controlling the wetting property of the surface through electric potential. The surface used in this report is, more specifically, an electrode covered with dielectrics, hence, called electrowetting-on-dielectric (EWOD). All the fluidic movement is confined between two plates, which we call parallel-plate channel, rather than through closed channels or on open surfaces. While transporting and merging droplets are easily verified, we discover that there exists a design criterion for a given set of materials beyond which the droplet simply cannot be cut by EWOD mechanism. The condition for successful cutting is theoretically analyzed by examining the channel gap, the droplet size and the degree of contact angle change by electrowetting on dielectric (EWOD). A series of experiments is run and verifies the criterion. A smaller channel gap, a larger droplet size and a larger change in the contact angle enhance the necking of the droplet, helping the completion of the cutting process. Creating droplets from a pool of liquid is highly related to cutting, but much more challenging. Although droplets may be created by simply pulling liquid out of a reservoir, the location of cutting is sensitive to initial conditions and turns out unpredictable. This problem of an inconsistent cutting location is overcome by introducing side electrodes, which pull the liquid perpendicularly to the main fluid path before activating the cutting. All four operations are carried out in air environment at 25 V-dc applied voltage.
引用
收藏
页码:70 / 80
页数:11
相关论文
共 29 条
[1]  
BERGE B, 1993, CR ACAD SCI II, V317, P157
[2]  
CHANDRASEKHAR S, 1961, HYDRODYNAMIC HYDROMA, pCH12
[3]  
Cho S.K., 2001, INT MECH ENG C EXP N
[4]  
Cho SK, 2002, PROC IEEE MICR ELECT, P32, DOI 10.1109/MEMSYS.2002.984073
[5]  
FADOU M, 1997, FUNDAMENTALS MICROFA, pCH9
[6]  
FAIR RB, 2001, EL DEV M
[7]   Enhancement of mixing by droplet-based microfluidics [J].
Fowler, J ;
Moon, HJ ;
Kim, CJ .
FIFTEENTH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2002, :97-100
[8]   Fluidics - The link between micro and nano sciences and technologies [J].
Ho, CM .
14TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2001, :375-384
[9]  
ISENBERG C, 1992, SCI SOAP FILMS SOAP, P131
[10]   Dielectrophoretic liquid actuation and nanodroplet formation [J].
Jones, TB ;
Gunji, M ;
Washizu, M ;
Feldman, MJ .
JOURNAL OF APPLIED PHYSICS, 2001, 89 (02) :1441-1448