Effect of heart rate on the diagnostic accuracy of 256-slice computed tomography angiography in the detection of coronary artery stenosis: ROC curve analysis

被引:5
|
作者
Wang, Gang [1 ]
Wu, Yifen [2 ]
Zhang, Zhentao [1 ]
Zheng, Xiaolin [1 ]
Zhang, Yulan [1 ]
Liang, Manqiu [1 ]
Yuan, Huanchu [1 ]
Shen, Haiping [1 ]
Li, Dewei [1 ]
机构
[1] Peoples Hosp Dongguan, Dept Radiol, 3 South Wandao Rd, Dongguan 523000, Guangdong, Peoples R China
[2] Peoples Hosp Dongguan, Dept Oncol, Dongguan 523000, Guangdong, Peoples R China
关键词
tomography; coronary angiography; coronary stenosis disease; receiver operating characteristic curve; MYOCARDIAL-INFARCTION; DISEASE; CT; CALCIFICATION; PATIENT; MSCT; CAG;
D O I
10.3892/etm.2016.3150
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The aim of the present study was to investigate the effect of heart rate (HR) on the diagnostic accuracy of 256-slice computed tomography angiography (CTA) in the detection of coronary artery stenosis. Coronary imaging was performed using a Philips 256-slice spiral CT, and receiver operating characteristic (ROC) curve analysis was conducted to evaluate the diagnostic value of 256-slice CTA in coronary artery stenosis. The HR of the research subjects in the study was within a certain range (39-107 bpm). One hundred patients suspected of coronary heart disease underwent 256-slice CTA examination. The cases were divided into three groups: Low HR (HR < 75 bpm), moderate HR (75 <= HR <90 bpm) and high HR (HR >= 90 bpm). For the three groups, two observers independently assessed the image quality for all coronary segments on a four-point ordinal scale. An image quality of grades 1-3 was considered diagnostic, while grade 4 was non-diagnostic. A total of 97.76% of the images were diagnostic in the low-HR group, 96.86% in the moderate-HR group and 95.80% in the high-HR group. According to the ROC curve analysis, the specificity of CTA in diagnosing coronary artery stenosis was 98.40, 96.00 and 97.60% in the low-, moderate- and high-HR groups, respectively. In conclusion, 256-slice coronary CTA can be used to clearly show the main segments of the coronary artery and to effectively diagnose coronary artery stenosis. Within the range of HRs investigated, HR was found to have no significant effect on the diagnostic accuracy of 256-slice coronary CTA for coronary artery stenosis.
引用
收藏
页码:1937 / 1942
页数:6
相关论文
共 50 条
  • [41] Effect of reader experience on variability, evaluation time and accuracy of coronary plaque detection with computed tomography coronary angiography
    Saur, Stefan C.
    Alkadhi, Hatem
    Stolzmann, Paul
    Baumueller, Stephan
    Leschka, Sebastian
    Scheffel, Hans
    Desbiolles, Lotus
    Fuchs, Thomas J.
    Szekely, Gabor
    Cattin, Philippe C.
    EUROPEAN RADIOLOGY, 2010, 20 (07) : 1599 - 1606
  • [42] Effect of age and plaque morphology on diagnostic accuracy of dual source multidetector computed tomography coronary angiography
    Sunman, Hamza
    Aytemir, Kudret
    Yorgun, Hikmet
    Canpolat, Ugur
    Taher, Ali
    Demiri, Edis
    Hazirolan, Tuncay
    Sahiner, Levent
    Kaya, Ergun B.
    Kabakci, Giray
    Tokgozoglu, Lale
    Oto, Ali
    JOURNAL OF GERIATRIC CARDIOLOGY, 2014, 11 (02) : 106 - 112
  • [43] Effect of decrease in heart rate variability on the diagnostic accuracy of 64-MDCT coronary angiography
    Leschka, Sebastian
    Scheffel, Hans
    Husmann, Lars
    Gaemperli, Oliver
    Marincek, Borut
    Kaufmann, Philipp A.
    Alkadhi, Hatem
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (06) : 1583 - 1590
  • [44] An Increased Diagnostic Accuracy of Significant Coronary Artery Stenosis Using 320-slice Computed Tomography with Model-based Iterative Reconstruction in Cases with Severely Calcified Coronary Arteries
    Takahashi, Manami
    Takaoka, Hiroyuki
    Ota, Joji
    Yashima, Satomi
    Kinoshita, Makiko
    Suzuki-Eguchi, Noriko
    Sasaki, Haruka
    Goto, Hiroki
    Aoki, Shuhei
    Kitahara, Hideki
    Sano, Koichi
    Kobayashi, Yoshio
    INTERNAL MEDICINE, 2023, 62 (02) : 169 - 176
  • [45] Diagnostic Accuracy of Dual-Source 64-Slice Multidetector Computed Tomography in Evaluation of Coronary Artery Bypass Grafts
    Sahiner, Levent
    Canpolat, Ugur
    Yorgun, Hikmet
    Hazirolan, Tuncay
    Karcaaltincaba, Musturay
    Sunman, Hamza
    Kaya, Ergun Baris
    Aytemir, Kudret
    Oto, Ali
    JOURNAL OF INVESTIGATIVE MEDICINE, 2012, 60 (08) : 1180 - 1185
  • [46] Diagnostic accuracy of in-stent coronary restenosis detection with multislice spiral computed tomography: a meta-analysis
    Michèle Hamon
    Laure Champ-Rigot
    Rémy Morello
    John W. Riddell
    Martial Hamon
    European Radiology, 2008, 18 : 217 - 225
  • [47] Diagnostic accuracy of in-stent coronary restenosis detection with multislice spiral computed tomography: a meta-analysis
    Hamon, Michele
    Champ-Rigot, Laure
    Morello, Remy
    Riddell, John W.
    Hamon, Martial
    EUROPEAN RADIOLOGY, 2008, 18 (02) : 217 - 225
  • [48] A meta-analysis comparing the diagnostic performance of computed tomography-derived fractional flow reserve and coronary computed tomography angiography at different levels of coronary artery calcium score
    Ma, Zhao
    Tu, Chenchen
    Zhang, Baoen
    Zhang, Dongfeng
    Song, Xiantao
    Zhang, Hongjia
    EUROPEAN RADIOLOGY, 2024, 34 (09) : 5621 - 5632
  • [49] Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease
    de Graaf, Fleur R.
    Schuijf, Joanne D.
    van Velzen, Joella E.
    Kroft, Lucia J.
    de Roos, Albert
    Reiber, Johannes H. C.
    Boersma, Eric
    Schalij, Martin J.
    Spano, Fabrizio
    Jukema, J. Wouter
    van der Wall, Ernst E.
    Bax, Jeroen J.
    EUROPEAN HEART JOURNAL, 2010, 31 (15) : 1908 - 1915
  • [50] Impact of Calcification on Diagnostic Accuracy of 64-Slice Spiral Computed Tomography for Detecting Coronary Artery Disease: A Single Center Experience
    Nazeri, Iraj
    Shahabi, Payman
    Tehrai, Mahmood
    Sharif-Kashani, Babak
    Nazeri, Alireza
    ARCHIVES OF IRANIAN MEDICINE, 2010, 13 (05) : 373 - 383