Tricuspid Regurgitation and Mortality in Patients With Transvenous Permanent Pacemaker Leads

被引:119
作者
Delling, Francesca N. [1 ,2 ]
Hassan, Zena K. [6 ,7 ]
Piatkowski, Gail [3 ]
Tsao, Connie W. [1 ,2 ]
Rajabali, Alefiyah [1 ,2 ]
Markson, Lawrence J. [4 ]
Zimetbaum, Peter J. [1 ,2 ]
Manning, Warren J. [1 ,2 ,5 ]
Chang, James D. [1 ,2 ]
Mukamal, Kenneth J. [1 ]
机构
[1] Harvard Univ, Beth Israel Deaconess Med Ctr, Sch Med, Dept Med, Boston, MA 02215 USA
[2] Harvard Univ, Beth Israel Deaconess Med Ctr, Sch Med, Div Cardiovasc, Boston, MA 02215 USA
[3] Harvard Univ, Beth Israel Deaconess Med Ctr, Sch Med, Dept Decis Support, Boston, MA 02215 USA
[4] Harvard Univ, Beth Israel Deaconess Med Ctr, Sch Med, Dept Informat Syst, Boston, MA 02215 USA
[5] Harvard Univ, Beth Israel Deaconess Med Ctr, Sch Med, Dept Radiol, Boston, MA 02215 USA
[6] Washington Hosp Ctr, Dept Med, Div Cardiol, Washington, DC 20010 USA
[7] Georgetown Univ, Med Ctr, Washington, DC 20007 USA
关键词
FOLLOW-UP; IMPLANTATION;
D O I
10.1016/j.amjcard.2015.12.038
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Estimates of the prevalence and importance of significant tricuspid regurgitation (STR) related to implantable device leads are based mainly on case reports, small observational studies, or mixed samples that include defibrillators. We sought to assess whether patients with permanent pacemaker (PPM) leads have an increased risk of STR and to determine mortality associated with PPM-related TR in a large longitudinal single-center cohort. We examined the prevalence of STR (defined as moderate-severe or >= 3+) among all echocardiograms performed from 2005 to 2011 excluding those with defibrillators. We then examined mortality risk according to the prevalence of PPM and STR after adjusting for cardiac co-morbidities, left ventricular systolic/diastolic function, and pulmonary artery hypertension. We screened 93,592 echocardiograms (1,245 with PPM) in 58,556 individual patients (634 with PPM). The prevalence of STR was higher in patients after PPM placement (mean age 79 +/- 3 years; 54% men) compared with those without a PPM (adjusted odds ratio 2.32; 95% confidence interval [CI] 1.54 to 3.49; p <0.0001). Among patients with a PPM lead, the presence of STR was associated with increased mortality (adjusted hazard ratio 1.40; 95% CI 1.04 to 2.11, p = 0.027, vs no STR). Compared with having neither a PPM lead nor STR, adjusted hazard ratios for death were 2.13 (95% CI 1.93 to 2.34) for STR but no PPM, 1.04 (0.89 to 1.22) for PPM without STR, and 1.55 (1.13 to 2.14) for PPM with STR. In conclusion, in a sample comprising >58,000 individual patients, PPM leads are associated with higher, risk of STR after adjustment for left ventricular systolic/diastolic function and pulmonary artery hypertension; similarly to STR from other cardiac pathologies, PPM-related STR is associated with increased mortality. (c) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:988 / 992
页数:5
相关论文
共 17 条
[1]   Interventional Cardiology Perspective of Functional Tricuspid Regurgitation [J].
Agarwal, Shikhar ;
Tuzcu, E. Murat ;
Rodriguez, E. Rene ;
Tan, Carmela D. ;
Rodriguez, L. Leonordo ;
Kapadia, Samir R. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (06) :565-U102
[2]   Tricuspid Regurgitation and Implantable Devices [J].
Al-Bawardy, Rasha ;
Krishnaswamy, Amar ;
Rajeswaran, Jeevanantham ;
Bhargava, Mandeep ;
Wazni, Oussama ;
Wilkoff, Bruce ;
Tuzcu, Emin Murat ;
Martin, David ;
Thomas, James ;
Blackstone, Eugene ;
Kapadia, Samir .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (02) :259-266
[3]   Tricuspid Regurgitation in Patients With Pacemakers and Implantable Cardiac Defibrillators: A Comprehensive Review [J].
Al-Bawardy, Rasha ;
Krishnaswamy, Amar ;
Bhargava, Mandeep ;
Dunn, Justin ;
Wazni, Oussama ;
Tuzcu, E. Murat ;
Stewart, William ;
Kapadia, Samir R. .
CLINICAL CARDIOLOGY, 2013, 36 (05) :249-254
[4]  
De Cock CC, 2000, PACE, V23, P423
[5]   Significant lead-induced tricuspid regurgitation is associated with poor prognosis at long-term follow-up [J].
Hoke, Ulas ;
Auger, Dominique ;
Thijssen, Joep ;
Wolterbeek, Ron ;
van der Velde, Enno T. ;
Holman, Eduard R. ;
Schalij, Martin J. ;
Bax, Jeroen J. ;
Delgado, Victoria ;
Marsan, Nina Ajmone .
HEART, 2014, 100 (12) :960-968
[6]   Tricuspid valve malfunction and ventricular pacemaker lead: Case report and review of the literature [J].
Iskandar, Said B. ;
Jackson, S. Ann ;
Fahrig, Stephen ;
Mechleb, Bassam K. ;
Garcia, Israel D. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (08) :692-697
[7]   The effect of transvenous pacemaker and implantable cardioverter defibrillator lead placement on tricuspid valve function: An observational study [J].
Kim, Juyong B. ;
Spevack, Daniel M. ;
Tunick, Paul A. ;
Bullinga, John R. ;
Kronzon, Itzhak ;
Chinitz, Larry A. ;
Reynolds, Harmony R. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (03) :284-287
[8]   Tricuspid Incompetence Following Permanent Pacemaker Implantation [J].
Klutstein, Marc ;
Balkin, Jonathan ;
Butnaru, Adi ;
Ilan, Michael ;
Lahad, Amnon ;
Rosenmann, David .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 :S135-S137
[9]   Chronic Performance of a Leadless Cardiac Pacemaker 1-Year Follow-Up of the LEADLESS Trial [J].
Knops, Reinoud E. ;
Tjong, Fleur V. Y. ;
Neuzil, Petr ;
Sperzel, Johannes ;
Miller, Marc A. ;
Petru, Jan ;
Simon, Jaroslav ;
Sediva, Lucie ;
de Groot, Joris R. ;
Dukkipati, Srinivas R. ;
Koruth, Jacob S. ;
Wilde, Arthur A. M. ;
Kautzner, Josef ;
Reddy, Vivek Y. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (15) :1497-1504
[10]   Tricuspid insufficiency does not increase early after permanent implantation of pacemaker leads [J].
Kucukarslan, N ;
Kirilmaz, A ;
Ulusoy, E ;
Yokusoglu, M ;
Gramatnikovski, N ;
Ozal, E ;
Tatar, H .
JOURNAL OF CARDIAC SURGERY, 2006, 21 (04) :391-394