Identification of microorganisms grown on chromogenic media by MALDI-TOF MS

被引:7
作者
Luthje, Petra [1 ]
Pranada, Arthur B. [2 ]
Carruthers-Lay, Duncan [3 ]
Desjardins, Marc [3 ]
Gaillot, Olivier [4 ]
Wareham, David [5 ,6 ]
Ciesielczuk, Holly [6 ]
Ozenci, Volkan [1 ]
机构
[1] Karolinska Univ, Hosp Huddinge, Karolinska Inst, Div Clin Microbiol, Stockholm, Sweden
[2] MW Dr Eberhard Ei Partner Dortmund UBAG, Dortmund, Germany
[3] Ottawa Hosp, Ottawa, ON, Canada
[4] Ctr Hosp Reg Univ Lille, Lille, France
[5] Queen Mary Univ London, London, England
[6] Barts Hlth NHS Trust, Div Infect, London, England
关键词
Bacterial identification; Chromogenic media; Culture conditions; MALDI-TOF MS; FLIGHT MASS-SPECTROMETRY; DESORPTION IONIZATION-TIME; ROUTINE IDENTIFICATION; BRUKER BIOTYPER; OF-FLIGHT; BACTERIA;
D O I
10.1016/j.mimet.2017.03.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) and chromogenic media are widely used in clinical microbiology laboratories to facilitate the rapid selection and identification of pathogens. The aim of this study was to evaluate whether usage of chromogenic media limits the diagnostic performance of MALDI-TOF MS for microbial identification. A total of 386 microorganisms collected and analyzed at five laboratories were included. Isolates were cultured on relevant chromogenic media and non-selective agar plates in parallel and identified using the Bruker MALDI-TOF MS. Among the tested isolates, no misidentification was recorded and there was no medium-related difference in the identification level. However, score values were overall slightly but significantly lower for isolates grown on chromogenic media. In conclusion, the use of chromogenic culture media tested here had no relevant impact on MALDI-TOF MS performance for diagnostic purposes. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 20
页数:4
相关论文
共 11 条
[1]   Comparison of Direct Colony Method versus Extraction Method for Identification of Gram-Positive Cocci by Use of Bruker Biotyper Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry [J].
Alatoom, Adnan A. ;
Cunningham, Scott A. ;
Ihde, Sherry M. ;
Mandrekar, Jayawant ;
Patel, Robin .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (08) :2868-2873
[2]   Rapid identification of bacteria from positive blood culture bottles by MALDI-TOF MS following short-term incubation on solid media [J].
Altun, Osman ;
Botero-Kleiven, Silvia ;
Carlsson, Sarah ;
Ullberg, Mans ;
Ozenci, Volkan .
JOURNAL OF MEDICAL MICROBIOLOGY, 2015, 64 :1346-1352
[3]   Effects of Solid-Medium Type on Routine Identification of Bacterial Isolates by Use of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry [J].
Anderson, Neil W. ;
Buchan, Blake W. ;
Riebe, Katherine M. ;
Parsons, Lauren N. ;
Gnacinski, Stacy ;
Ledeboer, Nathan A. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (03) :1008-1013
[4]   Fungal pigments inhibit the matrix-assisted laser desorption/ionization time-of-flight mass spectrometry analysis of darkly pigmented fungi [J].
Buskirk, Amanda D. ;
Hettick, Justin M. ;
Chipinda, Itai ;
Law, Brandon F. ;
Siegel, Paul D. ;
Slaven, James E. ;
Green, Brett J. ;
Beezhold, Donald H. .
ANALYTICAL BIOCHEMISTRY, 2011, 411 (01) :122-128
[5]   Optimization of Routine Identification of Clinically Relevant Gram-Negative Bacteria by Use of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry and the Bruker Biotyper [J].
Ford, Bradley A. ;
Burnham, Carey-Ann D. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (05) :1412-1420
[6]   Comparison of Bruker Biotyper Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometer to BD Phoenix Automated Microbiology System for Identification of Gram-Negative Bacilli [J].
Saffert, Ryan T. ;
Cunningham, Scott A. ;
Ihde, Sherry M. ;
Jobe, Kristine E. Monson ;
Mandrekar, Jayawant ;
Patel, Robin .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (03) :887-892
[7]   MALDI-TOF mass spectrometry: an emerging technology for microbial identification and diagnosis [J].
Singhal, Neelja ;
Kumar, Manish ;
Kanaujia, Pawan K. ;
Virdi, Jugsharan S. .
FRONTIERS IN MICROBIOLOGY, 2015, 6
[8]   Sample preparation of Gram-positive bacteria for identification by matrix assisted laser desorption/ionization time-of-flight [J].
Smole, SC ;
King, LA ;
Leopold, PE ;
Arbeit, RD .
JOURNAL OF MICROBIOLOGICAL METHODS, 2002, 48 (2-3) :107-115
[9]   Optimizing Identification of Clinically Relevant Gram-Positive Organisms by Use of the Bruker Biotyper Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry System [J].
TeKippe, Erin McElvania ;
Shuey, Sunni ;
Winkler, David W. ;
Butler, Meghan A. ;
Burnham, Carey-Ann D. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (05) :1421-1427
[10]   Effect of culture conditions on microorganism identification by matrix-assisted laser desorption ionization mass spectrometry [J].
Valentine, N ;
Wunschel, S ;
Wunschel, D ;
Petersen, C ;
Wahl, K .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2005, 71 (01) :58-64