Tests of a novel method to assay SNM using polarized photofission and its sensitivity in the presence of shielding

被引:10
|
作者
Mueller, J. M. [1 ,2 ]
Ahmed, M. W. [1 ,2 ,3 ]
Kafkarkou, A. [1 ,2 ]
Kendellen, D. P. [1 ,2 ]
Sikora, M. H. [1 ,4 ]
Spraker, M. C. [5 ]
Weller, H. R. [1 ,2 ]
Zimmerman, W. R. [1 ,2 ]
机构
[1] Triangle Univ Nucl Lab, Durham, NC 27710 USA
[2] Duke Univ, Dept Phys, Durham, NC 27708 USA
[3] N Carolina Cent Univ, Dept Math & Phys, Durham, NC 27707 USA
[4] George Washington Univ, Dept Phys, Washington, DC 20052 USA
[5] Univ North Georgia, Dept Phys, Dahlonega, GA 30597 USA
关键词
Active interrogation; Fission; Enrichment; Assay; Polarized beams; Neutron detectors; NEUTRON; U-238; RESONANCE; URANIUM; TH-232;
D O I
10.1016/j.nima.2014.12.022
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A novel method to identify Special Nuclear Material was recently developed (Mueller et al., 2014) [1]. This method relies upon using a linearly polarized gamma-ray beam to induce photofission of a sample and then comparing the prompt fission neutron yields in and out of the plane of beam polarization. The present paper will describe experimental tests of this new technique and assess its sensitivity in the presence of shielding. The capability of this technique W measure the enrichment of uranium was tested by using combinations of thin U-235 and U-238 foils of known enrichments. The sensitivity of this assay W shielding by lead, steel, and polyethylene was experimentally measured and simulated using GEANT4. These tests show that the measured asymmetry can indeed be used W determine the enrichment of materials composed of an admixture of U-235 and U-238, and this asymmetry is relatively insensitive W moderate amounts of shielding. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:107 / 113
页数:7
相关论文
共 50 条
  • [1] A novel method to assay special nuclear materials by measuring prompt neutrons from polarized photofission
    Mueller, J. M.
    Ahmed, M. W.
    Weller, H. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 754 : 57 - 62
  • [2] A novel drug sensitivity assay method for 3D cultured cell using an imaging device
    Sakamoto, Ruriko
    Sakemura, Noriko
    Shimomura, Manami
    Hirakawa, Noboru
    Watanabe, Hirotada
    Tanaka, Satoru
    Yoshida, Kaori
    Nakatsura, Tetsuya
    CANCER RESEARCH, 2011, 71
  • [3] Ultrabright fluorescent microsphere and its novel application for improving the sensitivity of immunochromatographic assay
    Zhang, Gang-gang
    Xu, Shao-lan
    Xiong, Yong-hua
    Duan, Hong
    Chen, Wen-yao
    Li, Xiang-min
    Yuan, Mei-fang
    Lai, Wei-hua
    BIOSENSORS & BIOELECTRONICS, 2019, 135 : 173 - 180
  • [4] RECONSTITUTION OF A FUNCTIONAL BETA-ADRENERGIC-RECEPTOR USING CHOLATE AND A NOVEL METHOD FOR ITS FUNCTIONAL ASSAY
    GAL, A
    BRAUN, S
    FEDER, D
    LEVITZKI, A
    EUROPEAN JOURNAL OF BIOCHEMISTRY, 1983, 134 (02): : 391 - 396
  • [5] A NOVEL POLYMER ENZYME LINKED IMMUNOBLOTTING ASSAY METHOD AND ITS APPLICATIONS(Ⅱ)
    Feng Hua LIU
    Feng LIU
    Yan Zhuo DENG
    Yun E ZENG
    Ren Xi ZHUO (Dept. of Chem.
    ChineseChemicalLetters, 1994, (05) : 387 - 388
  • [6] Improved assay sensitivity and robustness using Novel Mix&Go ™ coatings
    Beins, D.
    Monteiro, R.
    Gorse, D.
    Collett, S.
    Raineri, L.
    Maeji, J.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A224 - A224
  • [7] A novel isosurface segmentation method using common boundary tests
    Wang, Cuilan
    COMPUTERS & GRAPHICS-UK, 2023, 110 : 86 - 97
  • [8] A novel method for quantitative measurement of a therapeutic monoclonal antibody in the presence of its target protein using enzymatic digestion
    Doucet, Julie
    Avrameas, Alexandre
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 52 (04) : 565 - 570
  • [9] Development of novel high-sensitivity chemiluminescence assay for luminol using thiourea derivatives
    Ohno, K
    Arakawa, H
    Yoda, R
    Maeda, M
    LUMINESCENCE, 1999, 14 (06) : 355 - 360
  • [10] A METHOD OF DETERMINING BINARY MIXTURES BY DISTRIBUTION MEASUREMENTS, AND ITS APPLICATION TO THE ASSAY OF STRYCHNINE IN THE PRESENCE OF QUININE
    MORTON, C
    TINLEY, EH
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 1956, 8 (11) : 967 - 972