Evaluation of Quadrature Signal Generation Approaches for Single-Phase Electric Aircraft Grids

被引:2
作者
Jula, Bhumaiah [1 ]
Jarial, Raj Kumar [1 ]
Verma, Anant Kumar [2 ]
Burgos-Mellado, Claudio [2 ]
Torres, Miguel [2 ]
Gautam, Samir [3 ]
Ahmed, Hafiz [4 ]
Roncero-Sanchez, Pedro [5 ]
机构
[1] Natl Inst Technol Hamirpur, Elect Engn, Hamirpur 177005, India
[2] Univ OHiggins, Elect Power Convers Syst Lab SCoPE Lab, Rancagua 611, Chile
[3] Univ Sydney, Sch EIE, Sydney, NSW 2006, Australia
[4] Bangor Univ, Nucl Futures Inst, Bangor LL57 1UT, Gwynedd, Wales
[5] Univ Castilla La Mancha, Sch Ind Engn, Ciudad Real 13071, Spain
来源
2022 IEEE 10TH POWER INDIA INTERNATIONAL CONFERENCE, PIICON | 2022年
关键词
Amplitude estimation; Electric aircraft; Orthogonal signal generation; Phase estimation; Single-phase grid; POWER-SYSTEMS; LOCKED LOOP; PLL;
D O I
10.1109/PIICON56320.2022.10045107
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This article evaluates non-adaptive orthogonal signal generation (OSG) approaches to understand their suitability for single-phase electric aircraft (EA) grids. It is noteworthy that the OSG approaches are widely accepted filtering approaches solving the problem of accurately estimating the grid parameters, i.e., amplitude, phase, and frequency. Also, the limited information provided by the single-phase grid voltage signal can be elevated with better filtering capability such that phase-locked loops (PLLs) and frequency-locked loops (FLLs) can perform better under distorted grid voltage conditions. Keeping in view that the non-adaptive OSG approaches do not involve frequency feedback loops, thus demonstrating fast extraction of fundamental orthogonal signals, are considered for further investigation. However, the issue is that not all the OSG approaches are suitable for single-phase EA grids owing to the broader frequency variation range, i.e., 360 Hz to 900 Hz. Hence, it affects the dynamic performance abilities of PLLs and FLLs under wider frequency variations. Furthermore, unlike the utility grid, any OSG approach tuned and designed at the nominal frequency of the EA grid, i.e., 400 Hz, will not yield proper magnitude in the output and are prone to phase errors. Therefore, in this research, non-adaptive approaches are documented employing computationally simpler error correction approaches that can help estimate the error-free amplitude and phase information. The numerical and experimental investigation reveals that the EA grid-connected converters and active power filter applications can take advantage of the utility grid OSG approaches.
引用
收藏
页数:6
相关论文
共 18 条
  • [1] Quasi Type-1 PLL With Tunable Phase Detector for Unbalanced and Distorted Three-Phase Grid
    Ahmed, Hafiz
    Tir, Zoheir
    Verma, Anant Kumar
    Ben Elghali, Seifeddine
    Benbouzid, Mohamed
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2022, 37 (02) : 1369 - 1378
  • [2] Electric Power Systems in More and All Electric Aircraft: A Review
    Barzkar, Ashkan
    Ghassemi, Mona
    [J]. IEEE ACCESS, 2020, 8 (08): : 169314 - 169332
  • [3] Comparison of Two Three-Phase PLL Systems for More Electric Aircraft Converters
    Bifaretti, Stefano
    Zanchetta, Pericle
    Lavopa, Elisabetta
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (12) : 6810 - 6820
  • [4] Future of Electrical Aircraft Energy Power Systems: An Architecture Review
    Cano, Tania C.
    Castro, Ignacio
    Rodriguez, Alberto
    Lamar, Diego G.
    Khalil, Yehia F.
    Albiol-Tendillo, Laura
    Kshirsagar, Parag
    [J]. IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2021, 7 (03) : 1915 - 1929
  • [5] Third order sinusoidal integrator (TOSSI)-based control algorithm for shunt active power filter under distorted and unbalanced voltage conditions
    Chilipi, Rajasekharareddy
    Al Sayari, Naji
    Al Hosani, Khalifa
    Fasil, Muhammed
    Beig, Abul R.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 96 : 152 - 162
  • [6] A Global Convergence Estimator of Grid Voltage Parameters for More Electric Aircraft
    Dai, Zhiyong
    Yang, Jianwei
    Rao, Dingjia
    Zhang, Juxiang
    Zhang, Zhen
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (09) : 7540 - 7549
  • [7] dq-Frame Impedance Modeling of Three-Phase Grid-Tied Voltage Source Converters Equipped With Advanced PLLs
    Golestan, Saeed
    Ebrahimzadeh, Esmaeil
    Wen, Bo
    Guerrero, Josep M.
    Vasquez, Juan C.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (03) : 3524 - 3539
  • [8] Single-Phase PLLs: A Review of Recent Advances
    Golestan, Saeed
    Guerrero, Josep M.
    Vasquez, Juan C.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (12) : 9013 - 9030
  • [9] A Critical Examination of Frequency-Fixed Second-Order Generalized Integrator-Based Phase-Locked Loops
    Golestan, Saeed
    Mousazadeh, Seyyed Yousef
    Guerrero, Josep M.
    Vasquez, Juan C.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (09) : 6666 - 6672
  • [10] Dynamics Assessment of Advanced Single-Phase PLL Structures
    Golestan, Saeed
    Monfared, Mohammad
    Freijedo, Francisco D.
    Guerrero, Josep M.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (06) : 2167 - 2177