Comparative Assessment of Environment-Friendly Alternative to R134a in Vapour Compression Refrigeration System using Exergy Destruction

被引:1
作者
Sharma, Sudhanshu [1 ]
Dwivedi, V. K.
机构
[1] Galgotias Coll Engn & Technol, Dept Mech Engn, Gr Noida 201306, Uttarpradesh, India
来源
JOURNAL OF ENGINEERING RESEARCH | 2022年 / 10卷
关键词
Refrigeration; Exergy; Refrigerants; Coefficient of performance; Global warming; Ozone layer; OPTIMIZATION; PERFORMANCE; R1234YF; ENERGY;
D O I
10.36909/jer.ICMET.17205
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The goal of this research is to compare the performance of a vapour compression refrigeration system using R-600a to a similar system having R-134a as a refrigerant. Both refrigerants have no potential to deplete the ozone layer. However, because R-134a is an HCF, its global warming potential is rather strong, whereas R-600a's is nearly none. The two refrigerants' desirable properties are compared. R-600a is a better refrigerant for a vapour compression refrigeration system, according to this comparison. The average values of the required parameters are then presented once a number of trials have been completed. To compare the refrigerants, the coefficient of performance, refrigeration effect, Carnot COP, and second law efficiency were calculated. The findings show that R-600a is a superior refrigerant. The system's primary components' exergy destruction has also been calculated. It demonstrates that the compressor has depleted its maximal exergy. R-600a is a strong alternative to R-134a, which is currently utilized in household refrigerators, according to the analysis.
引用
收藏
页数:12
相关论文
共 11 条
[1]   Energy and exergy analysis of vapor compression-triple effect absorption cascade refrigeration system [J].
Agarwal, Shyam ;
Arora, Akhilesh ;
Arora, B. B. .
ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2020, 23 (03) :625-641
[2]   Exergy analysis of a vapour compression refrigeration system with r-22, R-407C and R-410A [J].
Arora, Akhilesh ;
Arora, B. B. ;
Pathak, B. D. ;
Sachdev, H. L. .
INTERNATIONAL JOURNAL OF EXERGY, 2007, 4 (04) :441-454
[3]   Optimization of a multistage vapor-compression refrigeration system for various refrigerants [J].
Baakeem, Saleh S. ;
Orfi, Jamel ;
Alabdulkarem, Abdullah .
APPLIED THERMAL ENGINEERING, 2018, 136 :84-96
[4]   Energy and exergy analysis of vapor compression refrigeration system using pure hydrocarbon refrigerants [J].
Bayrakci, Hilmi Cenk ;
Ozgur, Arif Emre .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (12) :1070-1075
[5]   Optimal design and environmental, energy and exergy analysis of a vapor compression refrigeration system using R290, R1234yf, and R744 as alternatives to replace R134a [J].
de Paula, Cleison Henrique ;
Duarte, Willian Moreira ;
Martins Rocha, Thiago Torres ;
de Oliveira, Raphael Nunes ;
Torres Maia, Antonio Augusto .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 113 (113) :10-20
[6]  
Dincer I., 2017, Refrigeration Systems Ad Applications, V3rd, DOI DOI 10.1002/9781119230793
[7]   Energy, exergy, economic and environmental (4E) analyses based comparative performance study and optimization of vapor compression-absorption integrated refrigeration system [J].
Jain, Vaibhav ;
Sachdeva, Gulshan ;
Kachhwaha, Surendra Singh .
ENERGY, 2015, 91 :816-832
[8]   Experimental exergy analysis of R513A to replace R134a in a small capacity refrigeration system [J].
Mota-Babiloni, Adrian ;
Belman-Flores, J. M. ;
Makhnatch, Pavel ;
Navarro-Esbri, Joaquin ;
Barroso-Maldonado, J. M. .
ENERGY, 2018, 162 :99-110
[9]   Energy and exergy analyses of R513a as a R134a drop-in replacement in a vapor compression refrigeration system [J].
Sun, Jian ;
Li, Wenhua ;
Cui, Borui .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 112 :348-356
[10]   Performance and exergy destruction analyses of optimal subcooling for vapor-compression refrigeration systems [J].
Yang, Min-Hsiung ;
Yeh, Rong-Hua .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 87 :1-10