The potential for mixed multiplexed and non-multiplexed data to improve the reconstruction quality of a multi-slit-slat collimator SPECT system

被引:31
作者
Mahmood, Shelan T. [1 ]
Erlandsson, Kjell
Cullum, Ian
Hutton, Brian F.
机构
[1] UCL, Inst Nucl Med, London, England
基金
英国工程与自然科学研究理事会;
关键词
ULTRA-HIGH-RESOLUTION; CODED-APERTURE; SENSITIVITY; IMAGES;
D O I
10.1088/0031-9155/55/8/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multiplexing is a way of increasing the sensitivity in a multi-slit-slat SPECT system by allowing the overlap of projections from neighboring apertures. The fundamental objective of multiplexing is to increase the signal-to-noise ratio for a given system resolution. Multiplexing may therefore lead to an improved tradeoff between resolution and sensitivity. Overlapped projections, however, introduce ambiguities in the data which can lead to non-uniqueness of solution for the inverse problem, deterioration in the quality of reconstruction and ultimately loss of resolution. Therefore, it is not straightforward to evaluate the advantage of the extra sensitivity gained by multiplexing, without first devising a method to overcome the image artifacts caused due to this overlapping of projection data. In this paper we investigate the effect of multiplexing on the reconstructed image quality and we determine whether reconstruction of multiplexed data could be improved by the addition of non-multiplexed data. For this purpose we have done simulations based on three digital phantoms. We compared the reconstructed images both qualitatively and quantitatively for different degrees of multiplexing and different fractions of non-multiplexed data. Our results indicate that the recovery coefficient (and therefore spatial resolution) can be maintained with a high degree of multiplexing leading to a significant increase in the SNR (up to 25%) due to a reduced noise level. This gain in the SNR corresponds to a 75% increase in counts or sensitivity which can be utilized to reduce acquisition time, patient dose or/and improve image quality.
引用
收藏
页码:2247 / 2268
页数:22
相关论文
共 30 条
  • [1] Accorsi R, 2001, IEEE T NUCL SCI, V48, P2411, DOI 10.1109/23.983251
  • [2] Derivation and validation of a sensitivity formula for slit-slat collimation
    Accorsi, Roberto
    Novak, John R.
    Ayan, Ahmet S.
    Metzler, Scott D.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (05) : 709 - 722
  • [3] Beekman FJ, 2005, J NUCL MED, V46, P1194
  • [4] Brasse D, 2004, IEEE NUCL SCI CONF R, P3868
  • [5] CHANG W, 2006, J NUCL MED, V47
  • [6] CHANG W, 2008, J NUCL MED, V49
  • [7] Fiorini C, 2005, IEEE NUCL SCI CONF R, P2938
  • [8] Fiorini C, 2008, IEEE MED IM C REC, P3961
  • [9] FastSPECT II: A second-generation high-resolution dynamic SPECT imager
    Furenlid, LR
    Wilson, DW
    Chen, YC
    Kim, H
    Pietraski, PJ
    Crawford, MJ
    Barrett, HH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 631 - 635
  • [10] 3-D PHANTOM TO SIMULATE CEREBRAL BLOOD-FLOW AND METABOLIC IMAGES FOR PET
    HOFFMAN, EJ
    CUTLER, PD
    DIGBY, WM
    MAZZIOTTA, JC
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) : 616 - 620