Sensitivity analysis of a vertical geothermal heat pump system

被引:130
作者
Han, Chanjuan [1 ]
Yu, Xiong [2 ,3 ,4 ]
机构
[1] Case Western Reserve Univ, Dept Civil Engn, 2104 Adelbert Rd,Bingham Bldg Room 203B, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Civil Engn, 2104 Adelbert Rd,Bingham Bldg Room 206, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Dept Elect Engn & Comp Sci, 2104 Adelbert Rd,Bingham Bldg Room 206, Cleveland, OH 44106 USA
[4] Case Western Reserve Univ, Dept Mech & Aerosp Engn, 2104 Adelbert Rd,Bingham Bldg Room 206, Cleveland, OH 44106 USA
基金
美国国家科学基金会;
关键词
Geothermal; Ground Coupled Heat Pump (GCHP); Coupled PDE; FEM; Sensitivity analysis; Optimization; GROUNDWATER ADVECTION; SOURCE MODEL; EXCHANGERS; BOREHOLE; PILE; ENERGY; PERFORMANCE; SIMULATION; TEMPERATURE;
D O I
10.1016/j.apenergy.2016.02.085
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper conducts sensitivity analyses on factors affecting the performance of vertical geothermal heat pump system, aiming to formulate design and operation strategies to improve its performance. It firstly describes the development of a 3D coupled Finite Element Model (FEM), which is utilized to simulate the steady state and transient behaviors of geothermal heat exchanger (GHE). The model holistically couples the heat exchange processes between pipe fluid flow, grouting backfill material, and adjacent ground associated with GHE. The model is firstly validated by comparison with the experimental data from an in-service GHE. Base on the calibrated model, a series of sensitivity analyses are conducted on the influence of geological, design, and operational factors intermittent operation mode of GHE achieves higher such as the initial ground temperature profile, GHE pipe installation depth, circulation fluid flow velocity, inlet temperature, subsurface water flow velocity, and material thermal properties. It also assess the behaviors of GHE under continuous operation versus intermittent operation modes. The results show that both design parameter (i.e., GHE pipe installation depth) and operational parameters (i.e., circulation fluid flow velocity) have major influence on the GHE performance. For a certain design length of GHE, the GHE performance improves with higher circulation fluid flow velocity until beyond a critical velocity. For GHE working in the heating mode, the heat extraction by GHE increases with decreasing fluid temperature at the inlet. In the geological factor aspect, the thermal conductivity of the ground material plays a very important role on the GHE performance operating in the continuous operation mode, while its specific heat capacity exerts no appreciable influence. However, for intermittent operation mode, both thermal conductivity and specific heat capacity of the ground, particularly the grouting materials, affect the ground thermal energy extraction. The results also showed that the presence of subsurface ground water flow improves the heat exchange of GHE. Operation wise, the GHE achieves higher performance and Coefficient of Performance (COP) under intermittent operation mode than under continuous operation mode. These observations point to ways to improve the performance of GHE from both design and operation aspects. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:148 / 160
页数:13
相关论文
共 53 条
[1]   Multilayer finite line source model for vertical heat exchangers [J].
Abdelaziz, Sherif L. ;
Ozudogru, Tolga Y. ;
Olgun, C. Guney ;
Martin, James R., II .
GEOTHERMICS, 2014, 51 :406-416
[2]  
Akrouch G.A., 2013, Energy Geostructures, ed, P175, DOI [10.1002/9781118761809.ch9, DOI 10.1002/9781118761809.CH9]
[3]   Efficient finite element formulation for geothermal heating systems. Part I: Steady state [J].
Al-Khoury, R ;
Bonnier, PG ;
Brinkgreve, RBJ .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2005, 63 (07) :988-1013
[4]   Dynamic numerical modeling of the usage of groundwater for cooling in north east Jordan - A geothermal case study [J].
Al-Zyoud, S. ;
Ruehaak, W. ;
Sass, I. .
RENEWABLE ENERGY, 2014, 62 :63-72
[5]   Experimental evaluation and dynamic simulation of a ground coupled heat pump for a commercial building [J].
Arteconi, Alessia ;
Brandoni, Caterina ;
Rossi, Guido ;
Polonara, Fabio .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2013, 37 (15) :1971-1980
[6]  
ASHRAE. American Society of Heating Refrigerating and Air-Conditioning Engineers, 2007, ASHRAE HDB HVAC APPL, pCh32
[7]   Temperature distributions in pavement and bridge slabs heated by using vertical ground-source heat pump systems [J].
Balbay, Asim ;
Esen, Mehmet .
ACTA SCIENTIARUM-TECHNOLOGY, 2013, 35 (04) :677-685
[8]  
Balbay A, 2010, SCI RES ESSAYS, V5, P3955
[9]   Energy and economic analysis of geothermal-solar trigeneration systems: A case study for a hotel building in Ischia [J].
Buonomano, Annamaria ;
Calise, Francesco ;
Palombo, Adolfo ;
Vicidomini, Maria .
APPLIED ENERGY, 2015, 138 :224-241
[10]   Investigations on the influence of aquifers on the ground temperature in ground-source heat pump operation [J].
Capozza, Antonio ;
De Carli, Michele ;
Zarrella, Angelo .
APPLIED ENERGY, 2013, 107 :350-363